An appropriate method of application of the hip-joint force and stress analysis of the pelvic bone, in particular the acetabulum, is necessary to investigate the changes in load transfer due to implantation and to calculate the reference stimulus for bone remodelling simulations. The purpose of the study is to develop a realistic 3D finite element (FE) model of the hemi-pelvis and to assess stress and strain distribution during a gait cycle. The FE modelling approach of the pelvic bone was based on CT scan data and image segmentation of cortical and cancellous bone boundaries. Application of hip-joint force through an anatomical femoral head having a cartilage layer was found to be more appropriate than a perfectly spherical head, thereby leading to more accurate stress–strain distribution in the acetabulum. Within the acetabulum, equivalent strains varied between 0.1% and 0.7% strain in the cancellous bone. High compressive (15–30 MPa) and low tensile (0–5 MPa) stresses were generated within the acetabulum. The hip-joint force is predominantly transferred from the acetabulum through the lateral cortex to the sacroiliac joint and the pubic symphysis. The study is useful to understand the load transfer within the acetabulum and for further investigations on acetabular prosthesis.
3 March 2009 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Failure mechanisms of the resurfaced femoral head include femoral neck fracture in the short term and stress shielding and implant loosening in the long term. In this study, finite element simulations of the resurfaced femur considering a debonded implant—cement interface, variable stem—bone interface conditions, and bone remodelling were used to study load transfer within the resurfaced femur and to investigate its relationship with known failure mechanisms. Realistic three-dimensional finite element models of an intact and resurfaced femur were used. Various conditions at the interface between the stem of the prosthesis and the bone were considered. Loading conditions included normal walking and stair climbing. For all stem—bone contact conditions, the tensile stresses in the cement mantle varied between 1 MPa and 5.4 MPa, except near the distal rim of the resurfacing component where they reached 5.4—7 MPa. In the case of full stem—bone contact, high von Mises stresses (114—121 MPa) were generated in the implant at the stem—cup junction. These stresses were considerably reduced (maximum von Mises stress, 76 MPa) where a gap was present at the stem—bone interface. Resurfacing led to strain shielding of the bone of the femoral head (20—75 per cent strain reductions) and periprosthetic bone resorption (50—80 per cent bone density reductions) for all interface stem—bone contact conditions. In the lateral femoral head and the proximal femoral shaft around the trochantric region, bone density reductions varied between 10 per cent and 50 per cent. Bone apposition was observed in the inferior—medial part of the femoral head and proximal femoral neck region. For full stem—bone contact, more load was transferred through the stem to the surrounding bone, exacerbating strain shielding. Although femoral hip resurfacing conserves bone stock at the primary operation, strain shielding and periprosthetic bone resorption might lead to eventual loosening over time. Post-operatively, the resurfacing procedure generated elevated strains (0.50—0.75 per cent strain) in the proximal femoral neck—component junction irrespective of the variation in interface conditions, indicating an initial risk of femoral neck fracture. Subsequent to bone remodelling, this strain concentration was considerably reduced (0.35—0.50 per cent strain), lowering the risk of neck fracture. In order to reduce the potential risk of neck fracture, patients should avoid activities which might induce high loading of the hip during the early post-operative period to allow the bone around the proximal femoral neck to remodel and heal.
4 January 2023 in Medical & Biological Engineering & Computing
One of the major causes of aseptic loosening in an uncemented implant is the lack of any attachment between the implant and the bone. The implant’s stability depends on a combination of primary stability (mechanical stability) and secondary stability (biological stability). The primary stability may affect the implant–bone interface condition and thus influence the load transfer and mechanical stimuli for bone remodelling in the resurfaced femur. This paper reports the results of a study into the affect of primary stability on load transfer and bone adaptation for an uncemented resurfaced femur. Three-dimensional finite element models were used to simulate the intact and resurfaced femurs and the bone remodelling. As a first step towards assessing the immediate post-operative condition, a debonded interfacial contact condition with varying levels of the friction coefficient (0.4, 0.5, and 0.6) was simulated at the implant–bone interface. Then, using a threshold value of micromotion of 50 µm, the implant–bone interfacial condition was varied along the implant–bone boundary to mechanically represent non-osseointegrated or osseointegrated regions of the interface. The considered applied loading conditions included normal walking and stair climbing. Resurfacing leads to strain shielding in the femoral head (20–75 per cent strain reductions). In immediate post-operative conditions, there was no occurrence of elevated strains in the cancellous bone around the proximal femoral neck–component junction resulting in a lower risk of neck fracture. Predominantly, the micromotions were observed to remain below 50 µm at the implant–bone interface, which represents 97–99 per cent of the interfacial surface area. The predicted micromotions at the implant–bone interface strongly suggest the likelihood of bone ingrowth onto the coated surface of the implant, thereby enhancing implant fixation. For the osseointegrated implant–bone interface, the effect of strain shielding was observed in a considerably greater bone volume in the femoral head as compared to the initial debonded interfacial condition. A 50–80 per cent periprosthetic bone density reduction was predicted as compared to the value of the intact femur, indicating bone resorption within the superior resurfaced head. Although primary fixation of the resurfacing component may be achieved, the presence of high strain shielding and peri-prosthetic bone resorption are a major concern.