Richard Jan van Arkel

Dr. Richard Jan van Arkel

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2021 in Osteoarthritis and Cartilage
Verified
Journal Article
Closed access
JSJ.C. Stoddart
J.C. Stoddart
ODO. Dandridge
O. Dandridge
AGA. Garner
A. Garner
JCJustin Cobb
Justin Cobb
RARichard Jan van Arkel
Richard Jan van Arkel

24 May 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
NKNupur Kohli
Nupur Kohli
JSJennifer C. Stoddart
Jennifer C. Stoddart
RARichard Jan van Arkel
Richard Jan van Arkel
Much research effort is being invested into the development of porous biomaterials that enhance implant osseointegration. Large micromotions at the bone-implant interface impair this osseointegration process, resulting in fibrous capsule formation and implant loosening. This systematic review compiled all the in vivo evidence available to establish if there is a universal limit of tolerable micromotion for implant osseointegration. The protocol was registered with the International Prospective Register for Systematic Reviews (ID: CRD42020196686). Pubmed, Scopus and Web of Knowledge databases were searched for studies containing terms relating to micromotion and osseointegration. The mean value of micromotion for implants that osseointegrated was 32% of the mean value for those that did not (112 ± 176 µm versus 349 ± 231 µm, p < 0.001). However, there was a large overlap in the data ranges with no universal limit apparent. Rather, many factors were found to combine to affect the overall outcome including loading time, the type of implant and the material being used. The tables provided in this review summarise these factors and will aid investigators in identifying the most relevant micromotion values for their biomaterial and implant development research.

25 November 2021 in Materials
Verified
Journal Article
Open access
PDF file
NTNathanael Tan
Nathanael Tan
RARichard Jan van Arkel
Richard Jan van Arkel
Stiff total hip arthroplasty implants can lead to strain shielding, bone loss and complex revision surgery. The aim of this study was to develop topology optimisation techniques for more compliant hip implant design. The Solid Isotropic Material with Penalisation (SIMP) method was adapted, and two hip stems were designed and additive manufactured: (1) a stem based on a stochastic porous structure, and (2) a selectively hollowed approach. Finite element analyses and experimental measurements were conducted to measure stem stiffness and predict the reduction in stress shielding. The selectively hollowed implant increased peri-implanted femur surface strains by up to 25 percentage points compared to a solid implant without compromising predicted strength. Despite the stark differences in design, the experimentally measured stiffness results were near identical for the two optimised stems, with 39% and 40% reductions in the equivalent stiffness for the porous and selectively hollowed implants, respectively, compared to the solid implant. The selectively hollowed implant’s internal structure had a striking resemblance to the trabecular bone structures found in the femur, hinting at intrinsic congruency between nature’s design process and topology optimisation. The developed topology optimisation process enables compliant hip implant design for more natural load transfer, reduced strain shielding and improved implant survivorship.

22 November 2017 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
PDF file
RARichard Jan van Arkel
Richard Jan van Arkel
SGShaaz Ghouse
Shaaz Ghouse
PMPiers E Milner
Piers E Milner
JJJonathan R T Jeffers
Jonathan R T Jeffers
Additive manufacturing offers exciting new possibilities for improving long‐term metallic implant fixation in bone through enabling open porous structures for bony ingrowth. The aim of this research was to investigate how the technology could also improve initial fixation, a precursor to successful long‐term fixation. A new barbed fixation mechanism, relying on flexible struts was proposed and manufactured as a push‐fit peg. The technology was optimized using a synthetic bone model and compared with conventional press‐fit peg controls tested over a range of interference fits. Optimum designs, achieving maximum pull‐out force, were subsequently tested in a cadaveric femoral condyle model. The barbed fixation surface provided more than double the pull‐out force for less than a third of the insertion force compared to the best performing conventional press‐fit peg (p < 0.001). Indeed, it provided screw‐strength pull out from a push‐fit device (1,124 ± 146 N). This step change in implant fixation potential offers new capabilities for low profile, minimally invasive implant design, while providing new options to simplify surgery, allowing for one‐piece push‐fit components with high levels of initial stability. © 2017 The Authors. Journal of Orthopaedic Research® Published by Wiley Periodicals, Inc. on behalf of the Orthopaedic Research Society. J Orthop Res 36:1508–1518, 2018.

21 August 2017 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
PDF file
MRMohamad Ikhwan Zaini Ridzwan
Mohamad Ikhwan Zaini Ridzwan
CSChamaiporn Sukjamsri
Chamaiporn Sukjamsri
BPBidyut Pal
Bidyut Pal
RARichard Jan van Arkel
Richard Jan van Arkel
ABAndrew Bell
Andrew Bell
UHUlrich N. Hansen
Ulrich N. Hansen
Proximal femoral fractures can be categorized into two main types: Neck and intertrochanteric fractures accounting for 53% and 43% of all proximal femoral fractures, respectively. The possibility to predict the type of fracture a specific patient is predisposed to would allow drug and exercise therapies, hip protector design, and prophylactic surgery to be better targeted for this patient rendering fracture preventing strategies more effective. This study hypothesized that the type of fracture is closely related to the patient‐specific femoral structure and predictable by finite element (FE) methods. Fourteen femora were DXA scanned, CT scanned, and mechanically tested to fracture. FE‐predicted fracture patterns were compared to experimentally observed fracture patterns. Measurements of strain patterns to explain neck and intertrochanteric fracture patterns were performed using a digital volume correlation (DVC) technique and compared to FE‐predicted strains and experimentally observed fracture patterns. Although loaded identically, the femora exhibited different fracture types (six neck and eight intertrochanteric fractures). CT‐based FE models matched the experimental observations well (86%) demonstrating that the fracture type can be predicted. DVC‐measured and FE‐predicted strains showed obvious consistency. Neither DXA‐based BMD nor any morphologic characteristics such as neck diameter, femoral neck length, or neck shaft angle were associated with fracture type. In conclusion, patient‐specific femoral structure correlates with fracture type and FE analyses were able to predict these fracture types. Also, the demonstration of FE and DVC as metrics of the strains in bones may be of substantial clinical value, informing treatment strategies and device selection and design. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:993–1001, 2018.

18 July 2018 in Journal of Bone and Joint Surgery
Verified
Journal Article
Open access
RARichard Jan van Arkel
Richard Jan van Arkel
KNK.C. Geoffrey Ng
K.C. Geoffrey Ng
SMSarah K. Muirhead-Allwood
Sarah K. Muirhead-Allwood
JJJonathan R.T. Jeffers
Jonathan R.T. Jeffers
Background: The hip joint capsule passively restrains extreme range of motion, protecting the native hip against impingement, dislocation, and edge-loading. We hypothesized that following total hip arthroplasty (THA), the reduced femoral head size impairs this protective biomechanical function. Methods: In cadavers, THA was performed through the acetabular medial wall, preserving the entire capsule, and avoiding the targeting of a particular surgical approach. Eight hips were examined. Capsular function was measured by rotating the hip in 5 positions. Three head sizes (28, 32, and 36 mm) with 3 neck lengths (anatomical 0, +5, and +10 mm) were compared. Results: Internal and external rotation range of motion increased following THA, indicating late engagement of the capsule and reduced biomechanical function (p < 0.05). Internal rotation was affected more than external. Increasing neck length reduced this hypermobility, while too much lengthening caused nonphysiological restriction of external rotation. Larger head sizes only slightly reduced hypermobility. Conclusions: Following THA, the capsular ligaments were unable to wrap around the reduced-diameter femoral head to restrain extreme range of motion. The posterior capsule was the most affected, indicating that native posterior capsule preservation is not advantageous, at least in the short term. Insufficient neck length could cause capsular dysfunction even if native ligament anatomy is preserved, while increased neck length could overtighten the anterior capsule. Clinical Relevance: Increased understanding of soft-tissue balancing following THA could help to prevent instability and improve early function. This study illustrates how head size and neck length influence the biomechanical function of the hip capsule in the early postoperative period.