Climate change is expected to influence cooling and heating energy demand of residential buildings and affect overall thermal comfort. Towards this end, the heating (HDD) and cooling (CDD) degree-days along with HDD + CDD were computed from an ensemble of seven high-resolution bias-corrected simulations attained from EURO-CORDEX under two Representative Concentration Pathways (RCP4.5 and RCP8.5). These three indicators were analyzed for 1971–2000 (from E-OBS) and 2011–2040, and 2041–2070, under both RCPs. Results predict a decrease in HDDs most significant under RCP8.5. Conversely, it is projected an increase of CDD values for both scenarios. The decrease in HDDs is projected to be higher than the increase in CDDs hinting to an increase in the energy demand to cool internal environments in Portugal. Statistically significant linear CDD trends were only found for 2041–2070 under RCP4.5. Towards 2070, higher(lower) CDD (HDD and HDD + CDD) anomaly amplitudes are depicted, mainly under RCP8.5. Within the five NUTS II regions projections revealed for 2041–2070 a decrease in heating requirements for Algarve and Lisbon Area higher in Faro, Lisboa and Setúbal whereas for North and Center regions results predicts an increase in cooling energy demand mainly in Bragança, Vila Real, Braga, Viana do Castelo, Porto and Guarda, higher under RCP8.5.
1 February 2004 in Proceedings of the Institution of Mechanical Engineers, Part D: Journal of Automobile Engineering
The objective of the work presented in this article was to study the airflow in a vehicle cabin with the typical dimensions and geometry of a multi-purpose vehicle (MPV) with a view to evaluating the thermal comfort through the equivalent temperature index. Tests were carried out on a life-size laboratory model of a car cabin, constructed with a simplified geometry, for different conditions: with and without the presence of a thermal mannequin, with different values of air velocity and temperature and with different regulation of the air inlets. The values of equivalent temperature were determined for each one of the various parts of the body, by two distinct forms: from the measurements performed by the thermal mannequin and from the physical parameters of the airflow, i.e. air velocity and temperature. The mapping of these flow parameters inside the cabin was done through a scanning process carried out with a traversing mechanism with eight low-velocity thermal anemometer probes, controlled from the exterior of the car cabin. Thus, using the values measured in plans in the neighbourhood of the different parts of the thermal mannequin, the equivalent temperature profiles were computed during tests carried out without the presence of the thermal mannequin.
Climate change is expected to influence cooling and heating energy demand of residential buildings and affect overall thermal comfort. Towards this end, the heating degree-day (HDD), the cooling degree-day (CDD) and the HDD+CDD were computed from an ensemble of 7 high-resolution bias-corrected simulations attained from EURO-CORDEX under RCP4.5 and RCP8.5. These three indicators were analyzed for 1971-2000 (from E-OBS) and 2011-2040 and 2041-2070, under both RCPs. Results show that the overall spatial distribution of HDD trends for the 3 time-periods points out an increase of energy demand to heat internal environments in Portugal's northern-eastern regions, most significant under RCP8.5. It is projected an increase of CDD values for both scenarios; however, statistically significant linear trends were only found for 2041-2070 under RCP4.5. The need for cooling is almost negligible for the remaining periods, though linear trend values are still considerably higher for 2041-2070 under RCP8.5. By the end of 2070, higher amplitudes for all indicators are depicted for southern Algarve and Alentejo regions, mainly under RCP8.5. For 2041-2070 the Centre and Alentejo (North and Centre) regions present major positive differences for HDD(CDD) under RCP4.5(RCP8.5), within the 5 NUTS II regions predicting higher heating(cooling) requirements for some locations.
Indoor environments are characterized by several pollutant sources. Some of these can be sufficiently characterized through the prediction of the airflow and pollutant distribution patterns. The purpose of this study was to simulate, analyze and compare different locations of known pollutant source inside a ventilated room. Computational fluid dynamics modelling approach was used to analyze the prediction of the airflow and pollutant distribution patterns for different locations of known pollutant source inside a ventilated room by mixing ventilation. Distinct areas of poor air quality, perfectly identified by concentration fields, were given. The indoor air quality obtained by the different simulated conditions was analyzed and compared. Pollutant concentration was not measured in the validation experiments (qualitative validation based on the velocity fields). Once the contaminant concentration fields are calculated based on the source location, the model is very useful to choose the best place to install any pollutant indoor equipment to preserve breathing zones. Providing an effective indoor air quality assessment to prevent exposure risk. The results would be useful for making decisions to optimize the design procedure, such as establish the best location to install polluting equipment, occupied areas and their interdependence with ventilation systems. In addition, this tool also helps to choose the best location and correct set point adjustment for the pollutant sensors.
1 September 2020 in Journal of Sustainable Development of Energy, Water and Environment Systems
With the increasing cost associated with energy consumption, climate change and the greater awareness of the population to issues related to energy and environmental efficiency, energy conservation in buildings has been encouraged, along with the development of several solutions based on a more sustainable construction. Building cooling is the most challenging issue in the Mediterranean climate. The roof is one of the main elements of the building's opaque envelope, where the choice of materials and the implementation of appropriate passive technologies determine the thermal performance of a building. The present work aims to assess the impact of natural ventilation of a roof cavity on the thermal environment of a dwelling house under Mediterranean summer conditions. An experimental study was developed in a small-scale prototype of a typical dwelling house, comprising a ceramic tile roof with vented eaves and insulated sub-tile panels according to the construction solution of the Humbelino Monteiro SA company. The thermal performance of this roof solution was assessed under real climatic conditions based on continuous measurements of the air velocity inside the air gap, the temperature of the air and the surface temperature of all roof layers. Weather conditions were also monitored continuously. Connected with the heat transfer mechanisms, the obtained temperature and air velocity profiles data were analysed and discussed.