Dan Popa

Dr. Dan Popa

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 October 2019 in IEEE Transactions on Robotics
Verified
Journal Article
Closed access
SCSven Cremer
Sven Cremer
SDSumit Kumar Das
Sumit Kumar Das
IWIndika B. Wijayasinghe
Indika B. Wijayasinghe
DPDan Popa
Dan Popa
FLFrank L. Lewis
Frank L. Lewis
With the rise of collaborative robots, the need for safe, reliable, and efficient physical human–robot interaction (pHRI) has grown. High-performance pHRI requires robust and stable controllers suitable for multiple degrees of freedom (DoF) and highly nonlinear robots. In this article, we describe a cascade-loop pHRI controller, which relies on human force and pose measurements and can adapt to varying robot dynamics online. It can also adapt to different users and simplifies the interaction by making the robot behave according to a prescribed dynamic model. In our controller formulation, two neural networks (NNs) in the “outer-loop” predict human motion intent and estimate a reference trajectory for the robot that the “inner-loop” controller follows. The inner-loop imposes a prescribed error dynamics (PED) with the help of a model-free neuroadaptive controller (NAC), which uses a NN to feedback linearize the robot dynamics. Lyapunov stability analysis gives weight tuning laws that guarantee that the error signals are bounded and the desired reference trajectory is achieved. Our control scheme was implemented on a Personal Robot 2 robot and validated through an exploratory experimental study in point-to-point collaborative motion. Results indicate fast convergence of our controller, and the resulting tracking error, motion jerk, and human control effort are comparable with other methods that require prior training, knowledge, and calibration.

12 November 2020 in Journal of Medical Internet Research
Verified
Journal Article
Open access
MSMohammad Saadazti
Mohammad Saadazti
MLM Cynthia Logsdon
M Cynthia Logsdon
SAShamsudeen Abubakar
Shamsudeen Abubakar
SDSumit Das
Sumit Das
PJPenelope Jankoski
Penelope Jankoski
DPDan Popa
Dan Popa
Background: According to the US Bureau of Labor Statistics, nurses will be the largest labor pool in the United States by 2022, and more than 1.1 million nursing positions have to be filled by then in order to avoid a nursing shortage. In addition, the incidence rate of musculoskeletal disorders in nurses is above average in comparison with other occupations. Robot-assisted health care has the potential to alleviate the nursing shortage by automating mundane and routine nursing tasks. Furthermore, robots in health care environments may assist with safe patient mobility and handling and may thereby reduce the likelihood of musculoskeletal disorders. Objective: This pilot study investigates the perceived ease of use and perceived usefulness (acceptability) of a customized service robot as determined by nursing students (as proxies for nursing staff in health care environments). This service robot, referred to as the Adaptive Robotic Nurse Assistant (ARNA), was developed to enhance the productivity of nurses through cooperation during physical tasks (eg, patient walking, item fetching, object delivery) as well as nonphysical tasks (eg, patient observation and feedback). This pilot study evaluated the acceptability of ARNA to provide ambulatory assistance to patients. Methods: We conducted a trial with 24 participants to collect data and address the following research question: Is the use of ARNA as an ambulatory assistive device for patients acceptable to nurses? The experiments were conducted in a simulated hospital environment. Nursing students (as proxies for nursing staff) were grouped in dyads, with one participant serving as a nurse and the other acting as a patient. Two questionnaires were developed and administrated to the participants based on the Technology Acceptance Model with respect to the two subscales of perceived usefulness and perceived ease of use metrics. In order to evaluate the internal consistency/reliability of the questionnaires, we calculated Cronbach alpha coefficients. Furthermore, statistical analyses were conducted to evaluate the relation of each variable in the questionnaires with the overall perceived usefulness and perceived ease of use metrics. Results: Both Cronbach alpha values were acceptably high (.93 and .82 for perceived usefulness and perceived ease of use questionnaires, respectively), indicating high internal consistency of the questionnaires. The correlation between the variables and the overall perceived usefulness and perceived ease of use metrics was moderate. The average perceived usefulness and perceived ease of use metrics among the participants were 4.13 and 5.42, respectively, out of possible score of 7, indicating a higher-than-average acceptability of this service robot. Conclusions: The results served to identify factors that could affect nurses’ acceptance of ARNA and aspects needing improvement (eg, flexibility, ease of operation, and autonomy level).

6 October 2023 in Sensors
Verified
Journal Article
Open access
PDF file
OOOlalekan O. Olowo
Olalekan O. Olowo
BHBryan Harris
Bryan Harris
Daniel SillsDaniel Sills
Daniel Sills
RZRuoshi Zhang
Ruoshi Zhang
ASAndriy Sherehiy
Andriy Sherehiy
DPDan Popa
Dan Popa
In this paper, we propose a novel tactile sensor with a “fingerprint” design, named due to its spiral shape and dimensions of 3.80 mm × 3.80 mm. The sensor is duplicated in a four-by-four array containing 16 tactile sensors to form a “SkinCell” pad of approximately 45 mm by 29 mm. The SkinCell was fabricated using a custom-built microfabrication platform called the NeXus which contains additive deposition tools and several robotic systems. We used the NeXus’ six-degrees-of-freedom robotic platform with two different inkjet printers to deposit a conductive silver ink sensor electrode as well as the organic piezoresistive polymer PEDOT:PSS-Poly (3,4-ethylene dioxythiophene)-poly(styrene sulfonate) of our tactile sensor. Printing deposition profiles of 100-micron- and 250-micron-thick layers were measured using microscopy. The resulting structure was sintered in an oven and laminated. The lamination consisted of two different sensor sheets placed back-to-back to create a half-Wheatstone-bridge configuration, doubling the sensitivity and accomplishing temperature compensation. The resulting sensor array was then sandwiched between two layers of silicone elastomer that had protrusions and inner cavities to concentrate stresses and strains and increase the detection resolution. Furthermore, the tactile sensor was characterized under static and dynamic force loading. Over 180,000 cycles of indentation were conducted to establish its durability and repeatability. The results demonstrate that the SkinCell has an average spatial resolution of 0.827 mm, an average sensitivity of 0.328 mΩ/Ω/N, expressed as the change in resistance per force in Newtons, an average sensitivity of 1.795 µV/N at a loading pressure of 2.365 PSI, and a dynamic response time constant of 63 ms which make it suitable for both large area skins and fingertip human–robot interaction applications.

8 May 2023 in Polymers
Verified
Journal Article
Open access
PDF file
PHPu Han
Pu Han
SZSihan Zhang
Sihan Zhang
ZYZhong Yang
Zhong Yang
MRM Faisal Riyad
M Faisal Riyad
DPDan Popa
Dan Popa
KHKeng Hsu
Keng Hsu
Material extrusion-based polymer 3D printing, one of the most commonly used additive manufacturing processes for thermoplastics and composites, has drawn extensive attention due to its capability and cost effectiveness. However, the low surface finish quality of the printed parts remains a drawback due to the nature of stacking successive layers along one direction and the nature of rastering of the extruded tracks of material. In this work, an in-process thermal radiation-assisted, surface reflow method is demonstrated that significantly improves the surface finish of the sidewalls of printed parts. It is observed that the surface finish of the printed part is drastically improved for both flat and curved surfaces. The effect of surface reflow on roughness reduction was characterized using optical profilometry and scanning electron microscopy (SEM), while the local heated spot temperature was quantified using a thermal camera.

16 May 2022 in Robotics
Verified
Journal Article
Open access
PDF file
CLCody Lee Lundberg
Cody Lee Lundberg
Hakki Erhan SevilHakki Erhan Sevil
Hakki Erhan Sevil
DBDeborah Behan
Deborah Behan
DPDan Popa
Dan Popa
This study presents the implementation of basic nursing tasks and human subject tests with a mobile robotic platform (PR2) for hospital patients. The primary goal of this study is to define the requirements for a robotic nursing assistant platform. The overall designed application scenario consists of a PR2 robotic platform, a human subject as the patient, and a tablet for patient–robot communication. The PR2 robot understands the patient’s request and performs the requested task by performing automated action steps. Two categories and three tasks are defined as: patient sitter tasks, include object fetching and temperature measurement, and patient walker tasks, including supporting the patient while they are using the walker. For this designed scenario and these tasks, human subject tests are performed with 27 volunteers in the Assistive Robotics Laboratory at the University of Texas at Arlington Research Institute (UTARI). Results and observations from human subject tests are provided. These activities are part of a larger effort to establish adaptive robotic nursing assistants (ARNA) for physical tasks in hospital environments.

1 October 2006
Verified
Conference Paper
Closed access
DPDan Popa
Dan Popa
MMMuhammad Faizan Mysorewala
Muhammad Faizan Mysorewala
FLF. L. Lewis
F. L. Lewis
The use of robotics in environmental monitoring applications requires distributed sensor systems optimized for effective estimation of relevant models subject to energy and environmental constraints. The mobile robot nodes are agents facilitating the repositioning of sensors in order to estimate a field distribution. This field distribution could be, for instance, water salinity in a lake, or air pollution over an industrial area. Each mobile robot node is characterized by sensor measurement noise in addition to localization uncertainty. This paper addresses an important problem for the robotic deployment of sensor networks, namely adaptive sampling (AS) by selection and repositioning of nodes in order to optimally estimate the parameters of distributed variable field models. The AS problem is posed as a sensor fusion problem within the extended Kalman filter (EKF) framework. We present simulation and experimental results of 2D deployment scenarios using low-cost mobile sensor robots developed in our lab