DANIELLE SOARES ROCHA VIEIRA

Prof. Dr. DANIELLE SOARES ROCHA VIEIRA


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2012 in Respiratory Care
Verified
Journal Article
Open access
DMDayane Montemezzo
Dayane Montemezzo
DVDANIELLE SOARES ROCHA VIEIRA
DANIELLE SOARES ROCHA VIEIRA
CTCarlos Julio Tierra-Criollo
Carlos Julio Tierra-Criollo
RBRaquel Rodrigues Britto
Raquel Rodrigues Britto
MVMarcelo Velloso
Marcelo Velloso
VPVerônica Franco Parreira
Verônica Franco Parreira
The measurement of maximal respiratory pressure (MRP) is a procedure widely used in clinical practice to evaluate respiratory muscle strength through the maximal inspiratory pressure (P(Imax)) and maximal expiratory pressure (P(Emax)). Its clinical applications include diagnostic procedures and evaluating responses to interventions. However, there is great variability in the equipment and measurement procedures. Understanding the impacts of the characteristics of different interfaces can augment the repeatability of this method and help to establish widely applicable predictive equations. The aim of this study was to evaluate the influence of 4 different interfaces on a subject's capacity to generate MRP and the impact of these interfaces on the repeatability of these measurements. Fifty healthy subjects (mean ± SD age 26.36 ± 4.89 y) with normal spirometry were evaluated. MRP was measured by a digital manometer connected to 4 interfaces using different combinations of mouthpieces and tubes. The following variables were analyzed: maximum mean pressure, peak pressure, plateau pressure, and plateau variation. Analysis of variance for repeated measures or a Friedman test was used to compare the 4 interfaces, with P < .008 after Bonferroni adjustment considered significant. There was no significant difference between the 4 interfaces with respect to maximum mean pressure, peak pressure, plateau pressure, or plateau variation for P(Imax) (P ≥ .49) or P(Emax) (P ≥ .11), nor did the number of tests performed to fulfill the criteria of repeatability for P(Imax) (P = .69) or P(Emax) (P = .47) differ among the 4 interfaces. P(Imax) and P(Emax) values seem not to be influenced by the different interfaces studied, suggesting that patient comfort and availability of interfaces can be considered.

29 December 2023 in Brazilian Journal of Physical Therapy
Verified
Journal Article
Closed access
NPNicole Pradi
Nicole Pradi
DVDANIELLE SOARES ROCHA VIEIRA
DANIELLE SOARES ROCHA VIEIRA
OROlívia Ramalho
Olívia Ramalho
ÍLÍtalo Ribeiro Lemes
Ítalo Ribeiro Lemes
ECEmanuella Cristina Cordeiro
Emanuella Cristina Cordeiro
DMDayane Montemezzo
Dayane Montemezzo

29 June 2020 in COPD: Journal of Chronic Obstructive Pulmonary Disease
Verified
Journal Article
Closed access
LMLiliane P. de Souza Mendes
Liliane P. de Souza Mendes
VPVerônica Franco Parreira
Verônica Franco Parreira
LSLissa M. Spencer
Lissa M. Spencer
DVDANIELLE SOARES ROCHA VIEIRA
DANIELLE SOARES ROCHA VIEIRA
JAJennifer Ailsey Alison
Jennifer Ailsey Alison
The Glittre-ADL test assesses the functional capacity for activities of daily living of people with chronic obstructive pulmonary disease (COPD). In the test, a weighted backpack is worn (2.5 kg for women and 5.0 kg for men). The differential in weight between men and women is not common in other tests of exercise capacity and may limit the comparison of the test between sexes. The primary aim of this study was to validate the Glittre-ADL test performed without the backpack in people with COPD. Forty participants with mild to severe COPD (mean ± SD age: 70 ± 6 years; FEV1: 48 ± 20%predicted) were recruited and performed two six-minute walk tests (visit 1); two Glittre-ADL tests with backpack (visit 2), and the Glittre-ADL test with and without the backpack, in random order (visit 3). The Glittre-ADL test time was shorter without the backpack than with the backpack [mean difference −0.37 min (95%CI −0.59 to −0.15)] and heart rate (HR) and oxygen saturation (SpO2) were equivalents between tests [−1.31 beats/minute (−3.92 to 1.30) and −0.95% (−2.27 to 0.37), respectively]. The Glittre-ADL test without the backpack elicited similar HR and SpO2 responses as the test with the backpack, indicating equivalence of physiological demand. Thus, the Glittre-ADL test without the backpack was a valid, responsive, and appropriate test to assess functional capacity for activities of daily living.

18 May 2021 in Revista de Enfermagem da UFSM
Verified
Journal Article
Open access
PDF file
BRBruna Vanti Da Rocha
Bruna Vanti Da Rocha
DVDANIELLE SOARES ROCHA VIEIRA
DANIELLE SOARES ROCHA VIEIRA
ISIone Schneider
Ione Schneider
Objetivo: analisar o perfil dos tabagistas em tratamento e os fatores associados ao abandono do tratamento e cessação do tabagismo em um programa municipal. Método: estudo transversal realizado em Araranguá, Santa Catarina com 109 pessoas do Programa Controle do Tabagismo, entre março e dezembro de 2018. Foram coletadas informações sociodemográficas e de saúde, incluindo sintomas depressivos, impulsividade e capacidade de enfrentamento. Realizou-se análises descritivas e inferenciais. Resultados: 40,4% dos participantes abandonaram o tratamento, grupo que obteve maior média para impulsividade. Os principais motivos relatados para o abandono do tratamento foram: “estar bem sem fumar”, situações relacionadas ao trabalho e sintomas de abstinência. Observou-se que 7,64% cessaram o tabagismo e 93,8% apresentavam dependência leve à nicotina. Conclusão: apesar do abandono ser alto, alguns permaneceram em cessação. Os com 49 anos ou menos foram tiveram abandono significativamente maior e a dependência à nicotina apresenta-se como dificultador significativo da cessação.

28 October 2022 in Physiotherapy Theory and Practice
Verified
Journal Article
Closed access
LFLetícia Ferronato
Letícia Ferronato
DVDANIELLE SOARES ROCHA VIEIRA
DANIELLE SOARES ROCHA VIEIRA
ARAna Rodrigues
Ana Rodrigues
CCChristian Coronel
Christian Coronel
NANúbia Pereira de Avelar
Núbia Pereira de Avelar
The Short Physical Performance Battery (SPPB) may be feasible for evaluating older adults undergoing myocardial revascularization surgery (MRS). However, it is necessary to verify its measurement p...

1 December 2017 in Fisioterapia e Pesquisa
Verified
Journal Article
Open access
PDF file
CACamila Thaís Adam
Camila Thaís Adam
CVCintia Teixeira Vieira
Cintia Teixeira Vieira
SASusana da Costa Aguiar
Susana da Costa Aguiar
DBDaiana Bündchen
Daiana Bündchen
DVDANIELLE SOARES ROCHA VIEIRA
DANIELLE SOARES ROCHA VIEIRA
RESUMO O objetivo deste trabalho foi realizar revisão sistemática de estudos que investigaram protocolos de desmame da ventilação não invasiva (VNI) em indivíduos adultos ou idosos hospitalizados. Por meio dessa revisão, baseada no protocolo Prisma, foram selecionados estudos de oito bases de dados publicados em português, inglês ou espanhol. Os desfechos primários desta revisão foram taxa de sucesso de desmame da VNI, duração da VNI e duração da permanência na unidade de terapia intensiva (UTI) e no hospital, e como desfecho secundário foram considerados os efeitos adversos associados aos protocolos de desmame da VNI. A qualidade metodológica dos ensaios clínicos foi avaliada por meio da escala PEDro, e a escala de Downs e Black foi utilizada para a avaliação dos estudos observacionais. Das 18.476 referências iniciais, quatro atenderam aos critérios de inclusão e foram incluídas nesta revisão. Dois dos quatro artigos eram ensaios clínicos randomizados e os outros dois eram estudos observacionais. Os estudos envolveram pacientes idosos com insuficiência respiratória, principalmente por exacerbação da doença pulmonar obstrutiva crônica (DPOC) e edema agudo de pulmão cardiogênico. Foram observadas elevadas taxas de sucesso de desmame em três dos quatro estudos, e um destes demonstrou a superioridade da implementação de um protocolo de desmame imediato na redução da duração da VNI e da permanência na UTI. No entanto, devido à heterogeneidade e à baixa qualidade metodológica dos estudos, não foi possível fazer recomendação sobre a implementação dos protocolos de desmame nessa população.