The measurement of maximal respiratory pressure (MRP) is a procedure widely used in clinical practice to evaluate respiratory muscle strength through the maximal inspiratory pressure (P(Imax)) and maximal expiratory pressure (P(Emax)). Its clinical applications include diagnostic procedures and evaluating responses to interventions. However, there is great variability in the equipment and measurement procedures. Understanding the impacts of the characteristics of different interfaces can augment the repeatability of this method and help to establish widely applicable predictive equations. The aim of this study was to evaluate the influence of 4 different interfaces on a subject's capacity to generate MRP and the impact of these interfaces on the repeatability of these measurements. Fifty healthy subjects (mean ± SD age 26.36 ± 4.89 y) with normal spirometry were evaluated. MRP was measured by a digital manometer connected to 4 interfaces using different combinations of mouthpieces and tubes. The following variables were analyzed: maximum mean pressure, peak pressure, plateau pressure, and plateau variation. Analysis of variance for repeated measures or a Friedman test was used to compare the 4 interfaces, with P < .008 after Bonferroni adjustment considered significant. There was no significant difference between the 4 interfaces with respect to maximum mean pressure, peak pressure, plateau pressure, or plateau variation for P(Imax) (P ≥ .49) or P(Emax) (P ≥ .11), nor did the number of tests performed to fulfill the criteria of repeatability for P(Imax) (P = .69) or P(Emax) (P = .47) differ among the 4 interfaces. P(Imax) and P(Emax) values seem not to be influenced by the different interfaces studied, suggesting that patient comfort and availability of interfaces can be considered.
29 December 2023 in Brazilian Journal of Physical Therapy
Introduction To avoid the selection of submaximal efforts during the assessment of maximal inspiratory and expiratory pressures (MIP and MEP), some reproducibility criteria have been suggested. Criteria that stand out are those proposed by the American Thoracic Society (ATS) and European Respiratory Society (ERS) and by the Brazilian Thoracic Association (BTA). However, no studies were found that compared these criteria or assessed the combination of both protocols. Objectives To assess the pressure values selected and the number of maneuvers required to achieve maximum performance using the reproducibility criteria proposed by the ATS/ERS, the BTA and the present study. Materials and method 113 healthy subjects (43.04 ± 16.94 years) from both genders were assessed according to the criteria proposed by the ATS/ERS, BTA and the present study. Descriptive statistics were used for analysis, followed by ANOVA for repeated measures and post hoc LSD or by Friedman test and post hoc Wilcoxon, according to the data distribution. Results The criterion proposed by the present study resulted in a significantly higher number of maneuvers (MIP and MEP – median and 25%-75% interquartile range: 5[5-6], 4[3-5] and 3[3-4] for the present study criterion, BTA and ATS/ERS, respectively; p < 0.01) and higher pressure values (MIP – mean and 95% confidence interval: 103[91.43-103.72], 100[97.19-108.83] and 97.6[94.06-105.95]; MEP: median and 25%-75% interquartile range: 124.2[101.4-165.9], 123.3[95.4-153.8] and 118.4[95.5-152.7]; p < 0.05). Conclusion The proposed criterion resulted in the selection of pressure values closer to the individual’s maximal capacity. This new criterion should be considered in future studies concerning MIP and MEP measurements.
The use of technology is an increasingly common practice among preschoolers. Little is known about the relationship between screen time exposure (STE) and aspects related to family and the environment. The aim is to characterize STE in Brazilian children aged between 3 and 5 years. Furthermore, the objective of this study is to associate the STE of children and of their parents with sociodemographic variables. Children aged between 3 and 5 years from southern Brazil and their parents participated in this study. To investigate STE, the researchers developed a specific questionnaire. To compare STE between age groups, the Kruskal–Wallis test was performed, followed by Dunn’s post hoc test. Spearman’s correlation and linear regression were used to correlate the variables. Children (n = 237) spend an average of 3.7 ± 0.8 h/day in front of screens. The STE of children had a moderately positive correlation with the STE of their parents (r = 0.4; p-value < 0.001). Only the variables of the children’s and parents’ STE had a significant and positive association. The model is significant (F = 6164, p-value < 0.001) and the residuals of the model met the necessary assumptions, with normal distribution, constant variance and without the presence of outliers. Children in southern Brazil remain in front of screens four times longer than the recommended amount of time. It was also found that the STE of parents directly influences that of their children.
Incentive spirometers (ISs) are clinical devices used in respiratory physical therapy to increase alveolar ventilation and functional residual capacity. To investigate factors that influence physical therapists from Minas Gerais in selecting a type of IS and the scientific background behind the use of ISs by physical therapists who work with patients with respiratory dysfunctions. Physical therapists from 13 hospital and non-hospital institutions (public/private) completed a self-administered questionnaire based on the current evidence on ISs. Indications and contraindications of ISs are not fully understood by most of the 168 physical therapists who completed the questionnaire. Volume-oriented IS was preferred over flow-oriented IS. However, only half of the physical therapists have a scientific background to justify the choice of one IS type rather than the other. Most physical therapists from Minas Gerais do not fully understand the indications and contraindications for ISs. Despite physical therapists stating their preference for volume-oriented IS, this choice is not necessarily based on current scientific evidence. The development of strategies to bring physical therapists closer to evidence-based practice is necessary to ensure best patient care.