Cheng Fang

Dr. Cheng Fang

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
CFCheng Fang
Cheng Fang
HHHe Hu
He Hu
JZJun Zou
Jun Zou
This papers reports the development of a novel focused optically-transparent ultrasound transducer with a wide bandwidth for photoacoustic microscopy (PAM). It consists of a 9- $\mu \text{m}$ -thick polyvinylidene fluoride (PVDF) film coated with Indium-tin oxide (ITO) and metal electrodes, which is laminated onto a concave glass lens. A new fabrication process was developed to ensure the formation of continuous ITO coatings on the curved transducer surface without fracturing. Both optical and acoustic experiments were conducted to characterize the performance of the transducer. The testing results show that the transducer has an optical transmittance of 60% (@ 532 nm), an acoustic center frequency of 24 MHz, and an acoustic bandwidth of 26 MHz. With an acoustic numerical aperture (NA) of 0.23, it provides a 0.13-mm acoustic focal spot and a 1.6-mm focal depth. For demonstration, a PAM setup was built for conducting PA imaging on different targets. In contrast to existing PAM systems, the use of the optically-transparent focused transducer allows a simpler and more compact configuration and easier alignment of the optical excitation and acoustic focal points. Such features are especially useful for the development of miniaturized PAM systems for handheld, wearable and even endoscopic applications.

31 August 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
ZYZhiyu Yan
Zhiyu Yan
CFCheng Fang
Cheng Fang
JZJun Zou
Jun Zou
This article reports the fine-tuning of the optical resonance wavelength (ORW) of surface-micromachined optical ultrasound transducer (SMOUT) arrays to enable ultrasound data readout with non-tunable interrogation light sources for photoacoustic computed tomography (PACT). Permanent ORW tuning is achieved by material deposition onto or subtraction from the top diaphragm of each element with sub-nanometer resolution. For demonstration, a SMOUT array is first fabricated, and its ORW is tuned for readout with an 808 nm laser diode (LD). Experiments are conducted to characterize the optical and acoustic performances of the elements within the center region of the SMOUT array. Two-dimensional and three-dimensional PACT (photoacoustic computed tomography) is also performed to evaluate the imaging performance of the ORW-tuned SMOUT array. The results show that the ORW tuning does not degrade the optical, acoustic, and overall imaging performances of the SMOUT elements. As a result, the fine-tuning method enables new SMOUT-based PACT systems that are low cost, compact, powerful, and even higher speed, with parallel readout capability.

10 May 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
CFCheng Fang
Cheng Fang
ZZZijie Zhao
Zijie Zhao
JFJie Fang
Jie Fang
JZJun Zou
Jun Zou
This paper reports a new optically-transparent focused P(VDF-TrFE) (poly(vinylidene fluoride-co-trifluoroethylene)) transducer for photoacoustic microscopy (PAM), which is fabricated by a new process based on pre-cutting and direct-lamination. Compared with the previous fabrication process, it is simpler, and makes it possible to achieve a high numerical aperture (NA) without stretching the (brittle) piezoelectric film. For demonstration, a prototype transducer has been fabricated with a 10-μm-thick 70/30 P(VDF-TrFE) film laminated onto a plano-concave glass lens with an acoustic NA of 0.64. Experimental characterizations show that the transducer has an optical transmittance of 88.6% (@ 532 nm), an acoustic center frequency and -3 dB bandwidth of 24 MHz and 29 MHz, respectively. Using the new optically-transparent focused P(VDF-TrFE) transducer, a PAM setup has been built to carry imaging experiments on different targets. Based on the experimental results, it can be concluded that the optically-transparent focused P(VDF-TrFE) transducer could be useful for the development of new PAM systems for different imaging applications.

19 September 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
EZEric Zou
Eric Zou
CFCheng Fang
Cheng Fang
DSDezhen Song
Dezhen Song
For improving the quality and profitability of watermelon production, rapid and non-destructive detection of watermelon ripeness is important. Conventional acoustic and optical testing methods are based on indirect measurements, which require complex modeling and suffer from low accuracy. This paper reports the initial investigation of using photoacoustics (PA), a hybrid modality of light and sound, for non-destructive detection of watermelon rind thickness and inner flesh redness, the two visual hallmarks of watermelon ripeness. A new low-cost handheld PA probe is designed and fabricated to enable rapid and reliable PA measurements in air by simply touching the watermelon surface. The data acquisition capability of the PA probe is tested on personal watermelon samples with different rind thickness and embedded red-ink solutions to simulate different levels of flesh redness. The rind thickness and flesh redness are estimated based on the time-of-flight and correlation with the peak-to-peak amplitude of the acquired PA signal, respectively. The captured PA signals are also used to differentiate the rind thickness and flesh redness with Machine Learning. The results show that the new PA probe could provide a promising solution for rapid and non-destructive detection of the ripeness of watermelons, especially those in the field before harvesting.

19 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
YTYuxuan Tang
Yuxuan Tang
YFYulang Feng
Yulang Feng
HHHe Hu
He Hu
CFCheng Fang
Cheng Fang
HDHao Deng
Hao Deng
JCJinghong Chen
Jinghong Chen
This paper presents a wideband low-noise amplifier (LNA) front-end with noise and distortion cancellation for high-frequency ultrasound transducers. The LNA employs a resistive shunt-feedback structure with a feedforward noise-canceling technique to accomplish both wideband impedance matching and low noise performance. A complementary CMOS topology was also developed to cancel out the second-order harmonic distortion and enhance the amplifier linearity. A high-frequency ultrasound (HFUS) and photoacoustic (PA) imaging front-end, including the proposed LNA and a variable gain amplifier (VGA), was designed and fabricated in a 180 nm CMOS process. At 80 MHz, the front-end achieves an input-referred noise density of 1.36 nV/sqrt (Hz), an input return loss (S11) of better than −16 dB, a voltage gain of 37 dB, and a total harmonic distortion (THD) of −55 dBc while dissipating a power of 37 mW, leading to a noise efficiency factor (NEF) of 2.66.

1 November 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
EBEdward Bao
Edward Bao
CFCheng Fang
Cheng Fang
DSDezhen Song
Dezhen Song