Yuxuan Tang

Dr. Yuxuan Tang

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 July 2021 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
YTYuxuan Tang
Yuxuan Tang
TTTodd Townsend
Todd Townsend
HDHao Deng
Hao Deng
YLYaqiang Liu
Yaqiang Liu
RZRunxi Zhang
Runxi Zhang
JCJinghong Chen
Jinghong Chen
This paper presents a low-power highly-linear multi-channel data acquisition (DAQ) system for silicon photomultiplier (SiPM) readout. A low-input impedance current-mode front-end with a programmable current gain is developed to achieve high-precision charge readout over a large dynamic range. An integrated 10-bit successive-approximation-register (SAR) analog-to-digital data converter (ADC) shared by 16 readout channels in a time-multiplexed manner is designed to reduce the overall chip area and power consumption of the SiPM readout. Implementation challenges of field-programmable gate array (FPGA)-based time-to-digital converters (TDCs) including bubble error, zero length bins, inter-clock region nonlinearity, and chain overflow, are addressed for high accuracy timing measurement. Multi-chain averaging is developed to improve the TDC linearity. Fabricated in a 180 nm CMOS process, the current-mode 16-channel readout application-specific integrated circuit (ASIC) achieves 3.6% maximum gain nonlinearity over an input dynamic range of 800 pC with dissipating 3.89 mW of power per readout channel, and the ADC achieves an SFDR of 58.34 dB and an SNDR of 51.37 dB at 16 MS/s. Implemented in a Xilinx 28 nm Kintex-7 FPGA, the 32-channel TDC achieves a 15 ps root mean square (RMS) resolution, a differential nonlinearity (DNL) of less than 4 ps, and an integral nonlinearity (INL) of less than 10 ps.

9 March 2020
Verified
Conference Paper
Open access
PDF file
TTTodd Townsend
Todd Townsend
YTYuxuan Tang
Yuxuan Tang
JCJinghong Chen
Jinghong Chen
A 32-channel, 15 ps resolution, Kintex 7 FPGA-based data acquisition (DAQ) system for time-of-flight (TOF) and time-over-threshold (TOT) SiPM readout is demonstrated along with a comparison to previous works. Focusing on modern FPGA concerns such as clock skew and bin realignment, the implementation difficulties of FPGA-based TDCs are discussed including bubble error, zero length bins, inter-clock region nonlinearity, and chain overflow. Linearity of the TDC is improved by multichain averaging with comparison of 1, 2, and 4 chains pre and post-calibration. Measurement results of the proposed TDC include 11 ps mean bin size, a differential nonlinearity (DNL) of less than 4 ps, and an integral nonlinearity (INL) of less than 10 ps.

19 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
YTYuxuan Tang
Yuxuan Tang
YFYulang Feng
Yulang Feng
HHHe Hu
He Hu
CFCheng Fang
Cheng Fang
HDHao Deng
Hao Deng
JCJinghong Chen
Jinghong Chen
This paper presents a wideband low-noise amplifier (LNA) front-end with noise and distortion cancellation for high-frequency ultrasound transducers. The LNA employs a resistive shunt-feedback structure with a feedforward noise-canceling technique to accomplish both wideband impedance matching and low noise performance. A complementary CMOS topology was also developed to cancel out the second-order harmonic distortion and enhance the amplifier linearity. A high-frequency ultrasound (HFUS) and photoacoustic (PA) imaging front-end, including the proposed LNA and a variable gain amplifier (VGA), was designed and fabricated in a 180 nm CMOS process. At 80 MHz, the front-end achieves an input-referred noise density of 1.36 nV/sqrt (Hz), an input return loss (S11) of better than −16 dB, a voltage gain of 37 dB, and a total harmonic distortion (THD) of −55 dBc while dissipating a power of 37 mW, leading to a noise efficiency factor (NEF) of 2.66.

31 January 2023 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
YTYuxuan Tang
Yuxuan Tang
HDHao Deng
Hao Deng
QFQingjun Fan
Qingjun Fan
YFYulang Feng
Yulang Feng
YLYaqiang Liu
Yaqiang Liu
JCJinghong Chen
Jinghong Chen
This paper presents an on-chip fast signal generator and a successive-approximation-register (SAR) analog-to-digital data converter (ADC) for silicon photomultiplier (SiPM) readout applications. The high-pass filter (HPF)-based fast-signal generator sharpens the rising edge of the standard SiPM output signal reducing time jitter due to the dark counts of the detector. It is implemented by leveraging the equivalent resistance of the current mirror transistor and the AC-coupling capacitor between the current mirror and the current discriminator to avoid hardware and power consumption overhead. Compared with off-chip solutions, the on-chip approach eliminates the packaging pins and high-speed buffers needed for carrying the fast signals reducing packaging complexity and power consumption of the readout system. The energy quantizer utilizes the SiPM charge integrator as the ADC track-and-hold (T/H) circuit to improve the front-end power efficiency. The fast signal generator and the SAR ADC are implemented in a current-mode application-specific integrated circuit (ASIC) designed in a 0.18 μm CMOS technology. Measurement results show that the on-chip fast signal generator is effective in improving the timing performance of the readout system. The timing resolutions are measured using SensL’s 3×3 mm 2 SiPM device with a terminal capacitance of 850 pF using an ultrashort laser pulser. Measurement results show that the fast signal generator improves the timing resolution by 23.4% compared with timing measurement using the standard output signal when the output charge is 300 pC. The ASIC achieved a measured ADC signal-to-noise-distortion ratio (SNDR) of 53.08 dB and a spurious-free dynamic range (SFDR) of 62.74 dB at 1 MS/s and a maximum front-end gain non-linearity of 3.3% over 20-800 pC input charge range while dissipating 4.1 mW of power from a 1.8 V supply.

20 April 2020
Verified
Conference Paper
Open access
PDF file
TTTodd Townsend
Todd Townsend
YTYuxuan Tang
Yuxuan Tang
JCJinghong Chen
Jinghong Chen
A low-power front-end with on-chip fast pulse generation and customized 10-bit single-ended SAR ADC is developed for SiPM readout design. The on-chip fast pulse generation improves the timing resolution without the need of extra I/O pins. The proposed SAR ADC, reusing the SiPM charge integrator and eliminating the power-hungry charging sensitive amplifier, consumes significantly less power compared with conventional solutions. Designed in a 0.18 μm 1P6M bulk CMOS technology, the front-end contains 16 channels of SiPM readouts, and each channel consumes a power of 3.8 mW. With on-chip HPF to shape input signals, the fast pulse generation approach reduces the long-tailed SPE pulses width from 50 ns to 3 ns. At 16 MS/s, the SAR ADC consumes 743 μW from a 1.8 V supply and achieves a SNDR of 57.53 dB and a SFDR of 66.31 dB, respectively.

1 January 2023 in Revista Española de Enfermedades Digestivas
Verified
Journal Article
Open access
YTYuxuan Tang
Yuxuan Tang
XNXiufan Ni
Xiufan Ni
SGSujun Gao
Sujun Gao
ZLZhang Li
Zhang Li
JYJian Yin
Jian Yin
ZZZhen Zhu
Zhen Zhu
A 54-year-old man was hospitalized with intermittent periumbilical pain for 1-month duration. Abdominal contrast-enhanced computed tomography (CT) revealed target-sign and a fat density mass measuring 2.0 × 2.5-cm in the distal ileum. Part mesenteric tissues and blood vessels were embedded and the wall of the affected intestinal tube was thickened and edematous. His symptom was alleviated after conservative treatment and he refused further management. The patient was hospitalized again with the same symptoms and abdominal CT findings 4 years later. Exploratory laparotomy was performed. A palpable mass in the ileum was found measuring 3.0 × 3.0-cm and partial enterectomy was performed. Postoperative histopathology revealed the resected mass was composed of proliferating mature adipocytes surrounded by few fibrous connective tissue. Hyperplastic fibroblast and inflammatory exudative necrotic tissue were found on the surface of the mass. The patient was diagnosed as ileum fibrolipoma with intussusception. He was discharged home uneventfully and no symptoms was observed in 12 months follow-up.