Kim Cluff

Dr. Kim Cluff

Wichita State University, Wichita, KS, USA

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2015 in Journal of Surgical Research
Verified
Journal Article
Closed access
Panagiotis KoutakisPanagiotis Koutakis
Panagiotis Koutakis
Sara MyersSara Myers
Sara Myers
KCKim Cluff
Kim Cluff
DHDuy M. Ha
Duy M. Ha
GHGleb Haynatzki
Gleb Haynatzki
IPIraklis Pipinos
Iraklis Pipinos

14 June 2008 in Sensing and Instrumentation for Food Quality and Safety
Verified
Journal Article
Closed access
PDF file
KCKim Cluff
Kim Cluff
GNGovindarajan Konda Naganathan
Govindarajan Konda Naganathan
JSJeyamkondan Subbiah
Jeyamkondan Subbiah
RLRenfu Lu
Renfu Lu
CCChris R. Calkins
Chris R. Calkins
ASAshok Samal
Ashok Samal

29 March 2018 in Sensors
Verified
Journal Article
Open access
PDF file
JGJacob Griffith
Jacob Griffith
KCKim Cluff
Kim Cluff
BEBrandon Eckerman
Brandon Eckerman
JAJessica Aldrich
Jessica Aldrich
RBRyan Becker
Ryan Becker
JPJeremy Patterson
Jeremy Patterson
Elevated intracranial fluid volume can drive intracranial pressure increases, which can potentially result in numerous neurological complications or death. This study’s focus was to develop a passive skin patch sensor for the head that would non-invasively measure cranial fluid volume shifts. The sensor consists of a single baseline component configured into a rectangular planar spiral with a self-resonant frequency response when impinged upon by external radio frequency sweeps. Fluid volume changes (10 mL increments) were detected through cranial bone using the sensor on a dry human skull model. Preliminary human tests utilized two sensors to determine feasibility of detecting fluid volume shifts in the complex environment of the human body. The correlation between fluid volume changes and shifts in the first resonance frequency using the dry human skull was classified as a second order polynomial with R2 = 0.97. During preliminary and secondary human tests, a ≈24 MHz and an average of ≈45.07 MHz shifts in the principal resonant frequency were measured respectively, corresponding to the induced cephalad bio-fluid shifts. This electromagnetic resonant sensor may provide a non-invasive method to monitor shifts in fluid volume and assist with medical scenarios including stroke, cerebral hemorrhage, concussion, or monitoring intracranial pressure.

1 August 2013 in American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
Verified
Journal Article
Closed access
PDF file
KCKim Cluff
Kim Cluff
DMDimitrios Miserlis
Dimitrios Miserlis
GNGovindarajan Konda Naganathan
Govindarajan Konda Naganathan
IPIraklis I. Pipinos
Iraklis I. Pipinos
Panagiotis KoutakisPanagiotis Koutakis
Panagiotis Koutakis
GCGeorge P. Casale
George P. Casale
Peripheral arterial disease (PAD), which affects ∼10 million Americans, is characterized by atherosclerosis of the noncoronary arteries. PAD produces a progressive accumulation of ischemic injury to the legs, manifested as a gradual degradation of gastrocnemius histology. In this study, we evaluated the hypothesis that quantitative morphological parameters of gastrocnemius myofibers change in a consistent manner during the progression of PAD, provide an objective grading of muscle degeneration in the ischemic limb, and correlate to a clinical stage of PAD. Biopsies were collected with a Bergström needle from PAD patients with claudication (n = 18) and critical limb ischemia (CLI; n = 19) and control patients (n = 19). Myofiber sarcolemmas and myosin heavy chains were labeled for fluorescence detection and quantitative analysis of morphometric variables, including area, roundness, perimeter, equivalent diameter, major and minor axes, solidity, and fiber density. The muscle specimens were separated into training and validation data sets for development of a discriminant model for categorizing muscle samples on the basis of disease severity. The parameters for this model included standard deviation of roundness, standard deviation of solidity of myofibers, and fiber density. For the validation data set, the discriminant model accurately identified control (80.0% accuracy), claudicating (77.7% accuracy), and CLI (88.8% accuracy) patients, with an overall classification accuracy of 82.1%. Myofiber morphometry provided a discriminant model that establishes a correlation between PAD progression and advancing muscle degeneration. This model effectively separated PAD and control patients and provided a grading of muscle degeneration within clinical stages of PAD.

22 May 2017 in Journal of Biomedical Materials Research Part A
Verified
Journal Article
Closed access
PDF file
LSLeyla Saeednia
Leyla Saeednia
LYLi Yao
Li Yao
MBMarcus Berndt
Marcus Berndt
KCKim Cluff
Kim Cluff
Ramazan AsmatuluRamazan Asmatulu
Ramazan Asmatulu

1 September 2013 in Meat Science
Verified
Journal Article
Closed access
KCKim Cluff
Kim Cluff
GNGovindarajan Konda Naganathan
Govindarajan Konda Naganathan
JSJeyamkondan Subbiah
Jeyamkondan Subbiah
ASAshok Samal
Ashok Samal
CCChris R. Calkins
Chris R. Calkins