Pedro Jesús Rodríguez de Rivera

Dr. Pedro Jesús Rodríguez de Rivera

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2019 in Journal of Thermal Biology
Verified
Journal Article
Closed access
PRPedro Jesús Rodríguez de Rivera
Pedro Jesús Rodríguez de Rivera
MRManuel Rodriguez De Rivera
Manuel Rodriguez De Rivera
FSFabiola Socorro
Fabiola Socorro
MRManuel Rodriguez De Rivera
Manuel Rodriguez De Rivera

18 September 2021 in Journal of Thermal Analysis and Calorimetry
Verified
Journal Article
Open access
PDF file
RRRodríguez de Rivera
Rodríguez de Rivera
PJPedro Jesús
Pedro Jesús
FSFabiola Socorro
Fabiola Socorro
Gustavo CallicoGustavo Callico
Gustavo Callico
Jose A Lopez CalbetJose A Lopez Calbet
Jose A Lopez Calbet
PRPedro Jesús Rodríguez de Rivera
Pedro Jesús Rodríguez de Rivera
A non-invasive sensor equipped with a programmable thermostat has been developed to assess in vivo the heat flow transmitted by conduction from human skin to the sensor thermostat. This device enables the assessment of the thermal properties of a 2 × 2 cm2 skin surface with a thermal penetration depth of 3–4 mm. In this work, we report the thermal magnitudes recorded with this sensor in 6 different areas (temple, hand, abdomen, thigh, wrist and heel) of 6 healthy subjects of different genders and ages, which were measured under resting conditions. Heat flow and equivalent thermal resistance are proportionally related to each other and are highly variable in magnitude and different for each zone. The heat capacity is also different for each zone. The heat flow values varied from 362 ± 17 mW at the temple to 36 ± 12 mW at the heel for the same subject, when the sensor thermostat was set at 26 °C. The equivalent thermal resistance ranged from 23 ± 2 K W−1 in the volar area of the wrist to 52 ± 4 KW−1 in the inner thigh area. The heat capacity varies from 4.8 ± 0.4 J K−1 in the heel to 6.4 ± 0.2 J K−1 in the abdomen. These magnitudes were also assessed over a 2 × 1 cm2 second-degree burn scar in the volar area of the wrist. The scar area had 27.6 and 11.6% lower heat capacity and equivalent thermal resistance, respectively, allowing an increased heat flow in the injured area. This work is a preliminary study of the measurement capacity of this new instrument.

1 June 2019 in Measurement
Verified
Journal Article
Closed access
PRPedro Jesús Rodríguez de Rivera
Pedro Jesús Rodríguez de Rivera
FSFabiola Socorro
Fabiola Socorro
MRManuel Rodriguez De Rivera
Manuel Rodriguez De Rivera

6 November 2016 in Sensors
Verified
Journal Article
Open access
PDF file
FSFabiola Socorro
Fabiola Socorro
PRPedro Jesús Rodríguez de Rivera
Pedro Jesús Rodríguez de Rivera
MRManuel Rodriguez De Rivera
Manuel Rodriguez De Rivera
We have developed a calorimetry sensor that can perform a local measurement of the surface heat dissipated from the human body. The operating principle is based on the law of conductive heat transfer: heat dissipated by the human body passes across a thermopile located between the individual and a thermostat. Body heat power is calculated from the signals measured by the thermopile and the amount of power dissipated across the thermostat in order to maintain a constant temperature. The first prototype we built had a detection area measuring 6 × 6 cm2, while the second prototype, which is described herein, had a 2 × 2 cm2 detection area. This new design offers three advantages over the initial one: (1) greater resolution and three times greater thermal sensitivity; (2) a twice as fast response; and (3) it can take measurements from smaller areas of the body. The sensor has a 5 mW resolution, but the uncertainty is greater, up to 15 mW, due to the measurement and calculation procedure. The order of magnitude of measurements made in healthy subjects ranged from 60 to 300 mW at a thermostat temperature of 28 °C and an ambient room temperature of 21 °C. The values measured by the sensor depend on the ambient temperature and the thermostat’s temperature, while the power dissipated depends on the individual’s metabolism and any physical and/or emotional activity.

23 June 2022 in Journal of Thermal Analysis and Calorimetry
Verified
Journal Article
Open access
PDF file
PRPedro Jesús Rodríguez de Rivera
Pedro Jesús Rodríguez de Rivera
FSFabiola Socorro
Fabiola Socorro
MRManuel Rodriguez De Rivera
Manuel Rodriguez De Rivera
Measurement of the heat capacity of human tissues is mainly performed by differential scanning calorimetry. In vivo measurement of this property is an underexplored field. There are few instruments capable of measuring skin heat capacity in vivo. In this work, we present a sensor developed to determine the heat capacity of a 4 cm2 skin area. The sensor consists of a thermopile equipped with a programmable thermostat. The principle of operation consists of a linear variation of the temperature of the sensor thermostat, while the device is applied to the skin. To relate the heat capacity of the skin with the signals provided by the sensor, a two-body RC model is considered. The heat capacity of skin varies between 4.1 and 6.6 JK−1 for a 2 × 2 cm2 area. This magnitude is different in each zone and depends on several factors. The most determining factor is the water content of the tissue. This sensor can be a versatile and useful tool in the field of physiology.

28 November 2017 in Sensors
Verified
Journal Article
Open access
PDF file
FSFabiola Socorro
Fabiola Socorro
PRPedro Jesús Rodríguez de Rivera
Pedro Jesús Rodríguez de Rivera
MRManuel Rodriguez De Rivera
Manuel Rodriguez De Rivera
MRManuel Rodriguez De Rivera
Manuel Rodriguez De Rivera
The accuracy of the direct and local measurements of the heat power dissipated by the surface of the human body, using a calorimetry minisensor, is directly related to the calibration rigor of the sensor and the correct interpretation of the experimental results. For this, it is necessary to know the characteristics of the body’s local heat dissipation. When the sensor is placed on the surface of the human body, the body reacts until a steady state is reached. We propose a mathematical model that represents the rate of heat flow at a given location on the surface of a human body by the sum of a series of exponentials: W(t) = A0 + ∑Aiexp(−t/τi). In this way, transient and steady states of heat dissipation can be interpreted. This hypothesis has been tested by simulating the operation of the sensor. At the steady state, the power detected in the measurement area (4 cm2) varies depending on the sensor’s thermostat temperature, as well as the physical state of the subject. For instance, for a thermostat temperature of 24 °C, this power can vary between 100–250 mW in a healthy adult. In the transient state, two exponentials are sufficient to represent this dissipation, with 3 and 70 s being the mean values of its time constants.