Hisham A Mously

Dr. Hisham A Mously


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2014 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
HMHisham A Mously
Hisham A Mously
MFMatthew Finkelman
Matthew Finkelman
RZRoya Zandparsa
Roya Zandparsa
HHHiroshi Hirayama
Hiroshi Hirayama

1 January 2020 in The Journal of Contemporary Dental Practice
Verified
Journal Article
Closed access
HMHisham A Mously
Hisham A Mously
This study aimed to evaluate and compare the effect of locator attachment and ball and socket (BS) attachment on the peri-implant and periabutment supporting structures on clinical pocket depth and gingival index in cases of limited interarch spaces in mandibular Kennedy class I implant-supported removable partial overdentures. A comparative clinical trial was conducted among twenty partially edentulous patients aged 30-60 years. The study participants were randomly divided into two study groups based on the attachment system used: group I - locator attachment, and group II - BS attachment. Two implants were positioned in the 1st or 2nd molar area following the two-stage surgical protocol. Evaluation of the peri-implant and periabutment supporting structures was done at the time of overdenture insertion and after 6, 12, and 18 months by measuring the pocket depth and gingival index. Inter- and intragroup comparisons were done using independent-samples t test and paired-sample t test respectively. p < 0.05 was considered statistically significant. It was observed that there was a statistically significant increase in the pocket depth around the implant as well as the abutment in both groups at 6, 12, and 18 months when compared to baseline. Intergroup comparison for pocket depth and gingival index revealed nonsignificant results. However, the values were higher in the BS group. The locator attachment group had lower, though statistically not significant, pocket depth and gingival index scores around both the dental implant and the natural abutment as compared with the BS attachment. Gingival health surrounding dental implant attachments is very crucial for the long-term success of dental implant, this could help the clinician to select the proper design for implant attachment underneath the over denture prosthesis.

7 September 2024 in Materials
Verified
Journal Article
Open access
PDF file
HMHisham A Mously
Hisham A Mously
GNGhada Naguib
Ghada Naguib
AHAbou Bakr Hossam Hashem
Abou Bakr Hossam Hashem
Ahmed Osama AbougaziaAhmed Osama Abougazia
Ahmed Osama Abougazia
ABAbdulelah M. Binmahfooz
Abdulelah M. Binmahfooz
MHMohamed Tharwat Hamed
Mohamed Tharwat Hamed
The literature presents insufficient data evaluating the displacement and micromotion effects resulting from the combined use of tooth-implant connections in fixed partial dentures. Analyzing the biomechanical behavior of tooth-implant fixed partial denture (FPD) prothesis is vital for achieving an optimum design and successful clinical implementation. The objective of this study was to determine the relative significance of connector design on the displacement and micromotion of tooth-implant-supported fixed dental prostheses under occlusal vertical loading. A unilateral Kennedy class I mandibular model was created using a 3D reconstruction from CT scan data. Eight simulated designs of tooth-implant fixed partial dentures (FPDs) were split into two groups: Group A with rigid connectors and Group B with non-rigid connectors. The models were subjected to a uniform vertical load of 100 N. Displacement, strain, and stress were computed using finite element analysis. The materials were defined as isotropic, homogeneous, and exhibiting linear elastic properties. This study focused on assessing the maximum displacement in various components, including the bridge, mandible, dentin, cementum, periodontal ligament (PDL), and implant. Displacement values were predominantly higher in Group B (non-rigid) compared to Group A (rigid) in all measured components of the tooth-implant FPDs. Accordingly, a statistically significant difference was observed between the two groups at the FPD bridge (p value = 0.021 *), mandible (p value = 0.021 *), dentin (p value = 0.043 *), cementum (p value = 0.043 *), and PDL (p value = 0.043 *). Meanwhile, there was an insignificant increase in displacement values recorded in the distal implant (p value = 0.083). This study highlighted the importance of connector design in the overall stability and performance of the prosthesis. Notably, the 4.7 mm × 10 mm implant in Group B showed a displacement nearly 92 times higher than its rigid counterpart in Group A. Overall, the 5.7 mm × 10 mm combination of implant length and diameter showcased the best performance in both groups. The findings demonstrate that wider implants with a proportional length offer greater resistance to displacement forces. In addition, the use of rigid connection design provides superior biomechanical performance in tooth-implant fixed partial dentures and reduces the risk of micromotion with its associated complications such as ligament overstretching and implant overload, achieving predictable prognosis and enhancing the stability of the protheses.