Ahmed Osama Abougazia

Dr. Ahmed Osama Abougazia

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2023 in Journal of Oral Implantology
Verified
Journal Article
Closed access
PDF file
GNGhada Hussein Naguib
Ghada Hussein Naguib
AHAbou Bakr H. Hashem
Abou Bakr H. Hashem
ZNZuhair S. Natto
Zuhair S. Natto
Ahmed Osama AbougaziaAhmed Osama Abougazia
Ahmed Osama Abougazia
HMHisham A. Mously
Hisham A. Mously
MHMohamed T. Hamed
Mohamed T. Hamed
The aim of this study is to evaluate the effectiveness of the implant diameter and length on force dissemination of tooth-implant and implant retained fixed restorations. A finite analysis model was used via a 3D simulation of a unilateral mandibular Kennedy Class I arch. Through thresholding the resultant assembly, a region of interest was selected from the computed tomography (CT) scan. Details of the diameter (D) and length (L) of implant were introduced. Ds used were 3.7, 4.7, and 5.7, while Ls used were 10, 11.5, and 13. The constant was the use of rigid connectors in both designs (implant-implant and implant-tooth fixed partial dentures [FPDs]) and the mesial implant (D 3.7 and L 11.5). Stress in cancellous bone around mesial abutment, which is the second premolar in tooth-implant FPD and mesial implant in the implant-implant FPD, revealed that the stress was significantly lower in tooth-implant FPD when compared with implant-implant FPD (21.1 ± 0.00 vs 46.1 ± 0.00, P < .001). Stress distribution in the bone around any implant depends on several factors such as diameter, length, and tooth-implant vs implant-implant support. The implant diameter was more significant for improved stress distribution than implant length. A moderate increase in the length of the implant consequently reduced stress.

20 September 2024 in International Dental Journal
Verified
Journal Article
Open access
HMHisham A. Mously
Hisham A. Mously
GNGhada Naguib
Ghada Naguib
Ahmed Osama AbougaziaAhmed Osama Abougazia
Ahmed Osama Abougazia
AAAfaf A. Almabadi
Afaf A. Almabadi
OQOsama Qutub
Osama Qutub
MHMohamed T. Hamed
Mohamed T. Hamed
Restoring extensively damaged endodontically treated teeth presents a challenging task due to the state of biomechanical deterioration affecting long-term prognosis. Therefore, the study aims to assess and compare the biomechanical performance of endocrowns and post core-crown restorations in anterior endodontically treated teeth with severe coronal structure loss. Following PRISMA guidelines, a systematic search was conducted using PubMed, Scopus, Web of Science, and Google Scholar for articles published from January 2014 to March 2024. Two independent reviewers screened and selected studies based on the predefined inclusion and exclusion criteria. The included studies were analyzed using the QUIN tool for risk of bias assessment in in-vitro studies. Additionally, the biomechanical outcomes were collected for qualitative comparative analysis. Twelve studies were included in this systematic review. In most studies, Endocrowns demonstrated comparable fatigue resistance under load to failure to post core-crown restorations. Endocrowns without ferrule exhibited a higher rate of debonding but had significantly more repairable failures. Conversely, post core-crown restorations demonstrated higher fracture resistance with the presence of ferrule, but were associated with more catastrophic failure patterns. Additionally, endocrowns generated lower stress levels in both the restorative material and the luting material compared to post core-crown restorations. Among the tested materials, lithium disilicate ceramics provided the best biomechanical properties. Overall, the studies included provided sufficient information for most evaluation criteria of the QUIN risk of bias assessment tool. Endocrowns are a viable and conservative approach for restoring endodontically treated anterior teeth, offering comparable biomechanical performance to traditional post core-crown restorations and less catastrophic failures. The findings of this systematic review suggest that endocrown restorations, especially with lithium disilicate ceramics and proper ferrule design, can improve fracture resistance and longevity of rehabilitated teeth, enhancing patient outcomes for severely damaged anterior endodontically treated teeth.

12 November 2024 in Biomimetics
Verified
Journal Article
Open access
PDF file
GNGhada Naguib
Ghada Naguib
Ahmed Osama AbougaziaAhmed Osama Abougazia
Ahmed Osama Abougazia
LALulwa AL-Turki
Lulwa AL-Turki
HMHisham A. Mously
Hisham A. Mously
AHAbou Bakr Hossam Hashem
Abou Bakr Hossam Hashem
MHMohamed Tharwat Hamed
Mohamed Tharwat Hamed
This study investigates the impact of tightening torque (preload) and the friction coefficient on stress generation and fatigue resistance of a Ti-6Al-4V abutment screw with an internal hexagonal connection under dynamic multi-axial masticatory loads in high-cycle fatigue (HCF) conditions. A three-dimensional model of the implant–abutment assembly was simulated using ANSYS Workbench 16.2 computer aided engineering software with chewing forces ranging from 300 N to 1000 N, evaluated over 1.35 × 107 cycles, simulating 15 years of service. Results indicate that the healthy range of normal to maximal mastication forces (300–550 N) preserved the screw’s structural integrity, while higher loads (≥800 N) exceeded the Ti-6Al-4V alloy’s yield strength, indicating a risk of plastic deformation under extreme conditions. Stress peaked near the end of the occluding phase (206.5 ms), marking a critical temporal point for fatigue accumulation. Optimizing the friction coefficient (0.5 µ) and preload management improved stress distribution, minimized fatigue damage, and ensured joint stability. Masticatory forces up to 550 N were well within the abutment screw’s capacity to sustain extended service life and maintain its elastic behavior.

10 June 2023 in Journal of Prosthodontics
Verified
Journal Article
Closed access
GNGhada Naguib
Ghada Naguib
AHAbou Bakr Hossam Hashem
Abou Bakr Hossam Hashem
Ahmed Osama AbougaziaAhmed Osama Abougazia
Ahmed Osama Abougazia
HMHisham A. Mously
Hisham A. Mously
OQOsama A. Qutub
Osama A. Qutub
MHMohamed T. Hamed
Mohamed T. Hamed

7 September 2024 in Materials
Verified
Journal Article
Open access
PDF file
HMHisham A Mously
Hisham A Mously
GNGhada Naguib
Ghada Naguib
AHAbou Bakr Hossam Hashem
Abou Bakr Hossam Hashem
Ahmed Osama AbougaziaAhmed Osama Abougazia
Ahmed Osama Abougazia
ABAbdulelah M. Binmahfooz
Abdulelah M. Binmahfooz
MHMohamed Tharwat Hamed
Mohamed Tharwat Hamed
The literature presents insufficient data evaluating the displacement and micromotion effects resulting from the combined use of tooth-implant connections in fixed partial dentures. Analyzing the biomechanical behavior of tooth-implant fixed partial denture (FPD) prothesis is vital for achieving an optimum design and successful clinical implementation. The objective of this study was to determine the relative significance of connector design on the displacement and micromotion of tooth-implant-supported fixed dental prostheses under occlusal vertical loading. A unilateral Kennedy class I mandibular model was created using a 3D reconstruction from CT scan data. Eight simulated designs of tooth-implant fixed partial dentures (FPDs) were split into two groups: Group A with rigid connectors and Group B with non-rigid connectors. The models were subjected to a uniform vertical load of 100 N. Displacement, strain, and stress were computed using finite element analysis. The materials were defined as isotropic, homogeneous, and exhibiting linear elastic properties. This study focused on assessing the maximum displacement in various components, including the bridge, mandible, dentin, cementum, periodontal ligament (PDL), and implant. Displacement values were predominantly higher in Group B (non-rigid) compared to Group A (rigid) in all measured components of the tooth-implant FPDs. Accordingly, a statistically significant difference was observed between the two groups at the FPD bridge (p value = 0.021 *), mandible (p value = 0.021 *), dentin (p value = 0.043 *), cementum (p value = 0.043 *), and PDL (p value = 0.043 *). Meanwhile, there was an insignificant increase in displacement values recorded in the distal implant (p value = 0.083). This study highlighted the importance of connector design in the overall stability and performance of the prosthesis. Notably, the 4.7 mm × 10 mm implant in Group B showed a displacement nearly 92 times higher than its rigid counterpart in Group A. Overall, the 5.7 mm × 10 mm combination of implant length and diameter showcased the best performance in both groups. The findings demonstrate that wider implants with a proportional length offer greater resistance to displacement forces. In addition, the use of rigid connection design provides superior biomechanical performance in tooth-implant fixed partial dentures and reduces the risk of micromotion with its associated complications such as ligament overstretching and implant overload, achieving predictable prognosis and enhancing the stability of the protheses.

15 May 2025 in Oral
Verified
Journal Article
Open access
PDF file
KJKhalid A. Al Johani
Khalid A. Al Johani
GNGhada Naguib
Ghada Naguib
AMAbdulghani Mira
Abdulghani Mira
AAAbeer Alnowaiser
Abeer Alnowaiser
MHMohamed Tharwat Hamed
Mohamed Tharwat Hamed
RKRayyan A. Kayal
Rayyan A. Kayal
Background/Objectives: Mycophenolate mofetil (MMF) has emerged as a valuable immunosuppressive agent used in the management of oral mucocutaneous diseases, particularly in autoimmune and inflammatory conditions, such as pemphigus vulgaris (PV), oral lichen planus (OLP), mucous membrane pemphigoid (MMP), systemic lupus erythematosus (SLE), erythema multiforme (EM) and recurrent aphthous stomatitis (RAS). This review consolidates the current evidence regarding MMF’s efficacy, safety and clinical applications across these conditions. Methods: A comprehensive review of literature was performed, focusing on the mechanism of action, dosing strategies, therapeutic outcomes and adverse effects associated with MMF therapy in oral mucocutaneous diseases. The potential of therapeutic drug monitoring (TDM) in optimizing MMF therapy and minimizing adverse effects was also explored. Results: The review demonstrates that MMF is effective in inducing disease remission in up to 80% of patients with PV, with notable steroid-sparing effects. In OLP, MMF provided significant clinical improvement, especially in patients with severe and refractory forms of the disease. For MMP, MMF showed an 89% response rate, particularly when combined with corticosteroids, though gastrointestinal side effects were noted in some patients. In SLE, MMF was effective in managing both renal and non-renal manifestations, with favorable remission rates observed in patients receiving MMF therapy. For EM, MMF’s effectiveness was limited, with only a small number of patients responding to therapy. In RAS, there is limited evidence of MMF’s efficacy, with only partial improvement in severe cases reported. MMF is a promising immunomodulatory therapy for oral mucocutaneous diseases, particularly in reducing corticosteroid dependence and improving patient outcomes. However, the variability in the study designs, dosages and patient populations complicates the generalization of these findings. Conclusions: There is a pressing need for randomized controlled trials to validate MMF’s efficacy and long-term safety across all disease categories. The integration of therapeutic drug monitoring (TDM) shows potential for improving disease control and minimizing adverse effects, making it a key consideration for future research.