Objective: In clinical intracytoplasmic sperm injection (ICSI), a motile sperm must be immobilized before insertion into an oocyte. This paper aims to develop a robotic system for automated tracking, orientation control, and immobilization of motile sperms for clinical ICSI applications. Methods: We adapt the probabilistic data association filter by adding sperm head orientation into state variables for robustly tracking the sperm head and estimating sperm tail positions under interfering conditions. The robotic system also utilizes a motorized rotational microscopy stage and a new visual servo control strategy that predicts and compensates for sperm movements to actively adjust sperm orientation for immobilizing a sperm swimming in any direction. Results: The system robustly tracked sperm head with a tracking success rate of 96.0% and estimated sperm tail position with an accuracy of 1.08 μm under clinical conditions where the occlusion of the target sperm and interference from other sperms occur. Experimental results from robotic immo bilization of 400 sperms confirmed that the system achieved a consistent immobilization success rate of 94.5%, independent of sperm velocity or swimming direction. Conclusion: Our adapted tracking algorithm effectively distinguishes the target sperm from interfering sperms. Predicting and compensating for sperm move ments significantly reduce the positioning error during sperm orientation control. These features make the robotic system suitable for automated sperm immobilization. Significance: The robotic system eliminates stringent skill requirements in manual sperm immobilization. It is capable of manipulating sperms swimming in an arbitrary direction with a high success rate.
20 November 2017 in Journal of Micromechanics and Microengineering
Mechanical manipulation and characterization of single cells are important experimental techniques in biological and medical research. Because of the microscale sizes and highly fragile structures of cells, conventional cell manipulation and characterization techniques are not accurate and/or efficient enough or even cannot meet the more and more demanding needs in different types of cell-based studies. To this end, novel microelectromechanical systems (MEMS)-based technologies have been developed to improve the accuracy, efficiency, and consistency of various cell manipulation and characterization tasks, and enable new types of cell research. This article summarizes existing MEMS-based platforms developed for cell mechanical manipulation and characterization, highlights their specific design considerations making them suitable for their designated tasks, and discuss their advantages and limitations. In closing, an outlook into future trends is also provided.
2 February 2018 in IEEE Transactions on Nanotechnology
Electrospinning is a technique for creating continuous nanofibrous networks that can architecturally be similar to the structure of extracellular matrix (ECM). In this work, a simple and semi-automatic electrostatic spinning system is designed, and a method of multi-layer composite electrostatic spinning is adopted, which is called the hierarchical construction (Sandwich mode). Then a kind of PLGA/silk fibroin composite electrospinning nanofibrous scaffolds is proposed for the growth of skin cells in combination with the good characters of silk fibroin and PLGA. The SEM experiment of the silk fibroin/PLGA composite nanofibers indicated that the prepared nanofibers are smooth, uniform in size and have good porosity. The wrinkled contrast test is shown that this nanofiber scaffold remain flat in the culture medium as the original, and is basically not shrink. The water absorption experimental results show that the composite nanofiber scaffold has good hydrophilicity, and the water absorption increases with time is not obvious. The cell culture experiment is also shown that the skin cells can proliterate on the scaffold.
5 November 2019 in ACS Biomaterials Science & Engineering
Conventionally, intracytoplasmic sperm injection (ICSI) in the mouse is conducted with piezo-drills that use a droplet of mercury for damping. The use of mercury causes concerns of toxicity and contamination. Although Fluorinert can be used as a substitute for mercury to reduce piezo-drill’s lateral vibration, the damping effect is not as satisfactory as mercury. In this work, a modified piezo-drill without using mercury was developed for the cellular piercing of mouse oocytes. Experimentally, appropriate parameters of driving voltage and frequency were obtained for the penetration of the zona pellucida of mouse oocytes. Furthermore, the lateral vibration of the injection pipette is lower than 1 μm in deionized water, which is not observable at 400 magnificence. With the piezo-drill without using mercury, the system performs the cellular piercing of mouse oocytes with a maximum cleavage rate of 94.7% (n = 117).
13 March 2020 in IEEE Transactions on Control Systems Technology
This brief proposes the first model reference adaptive control (MRAC) method for aortic pressure (AoP) regulation and maintaining the heart's physiological aerobic metabolism in ex vivo heart perfusion (EVHP). A mathematical model of the EVHP was established to describe the hemodynamic behavior of EVHP and quantify the changes in cardiac parameters. A reference model consisting of a virtual proportional-integral-derivative (PID) controller and the EVHP model was employed to generate the reference trajectory of AoP. An adaptation algorithm tunes the control parameters based on the reference model and the isolated heart. Experiments were conducted using large animal hearts (50 ± 5 kg porcine) to validate the adaptive controller's performance for stepwise and fast switching AoP references. The results confirmed the effectiveness of the proposed controller for regulating the AoP in isolated porcine hearts, in an accurate (mean error less than 2 mmHg) and fast (4-8 s of settling time) manner.