BALAJI GUTTA

Mr. BALAJI GUTTA

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 August 2025 in Inventions
Verified
Journal Article
Open access
PDF file
Preetham GoliPreetham Goli
Preetham Goli
SGSRINIVASA RAO GAMPA
SRINIVASA RAO GAMPA
AAAmarendra Alluri
Amarendra Alluri
BGBALAJI GUTTA
BALAJI GUTTA
KJKiran Jasthi
Kiran Jasthi
DDDebapriya Das
Debapriya Das
This paper presents a novel methodology for the optimal sizing of solar photovoltaic (PV) systems in distribution networks by determining the monthly optimum tilt and azimuth angles to maximize solar energy capture. Using one year of solar irradiation data, the Grey Wolf Optimizer (GWO) is employed to optimize the tilt and azimuth angles with the objective of maximizing monthly solar insolation. Unlike existing approaches that assume fixed azimuth angles, the proposed method calculates both tilt and azimuth angles for each month, allowing for a more precise alignment with solar trajectories. The optimized orientation parameters are subsequently utilized to determine the optimal number and placement of PV panels, as well as the optimal location and sizing of shunt capacitor (SC) banks, for the IEEE 69-bus distribution system. This optimization is performed under peak load conditions using the GWO, with the objectives of minimizing active power losses, enhancing voltage profile stability, and maximizing PV system penetration. The long-term impact of this approach is assessed through a 20-year energy and economic savings analysis, demonstrating substantial improvements in energy efficiency and cost-effectiveness.

12 November 2024 in Inventions
Verified
Journal Article
Open access
PDF file
AAAmarendra Alluri
Amarendra Alluri
SGSRINIVASA RAO GAMPA
SRINIVASA RAO GAMPA
BGBALAJI GUTTA
BALAJI GUTTA
MBMahesh Babu Basam
Mahesh Babu Basam
KJKiran Jasthi
Kiran Jasthi
DDDebapriya Das
Debapriya Das
In this paper, a multi-objective grey wolf optimization (GWO) algorithm based Bidirectional Long Short Term Memory (BiLSTM) network machine learning (ML) model is proposed for finding the optimum sizing of distributed generators (DGs) and shunt capacitors (SHCs) to enhance the performance of distribution systems at any desired load factor. The stochastic traits of evolutionary computing methods necessitate running the algorithm repeatedly to confirm the global optimum. In order to save utility engineers time and effort, this study introduces a BiLSTM network-based machine learning model to directly estimate the optimal values of DGs and SHCs, rather than relying on load flow estimates. At first, a multi-objective grey wolf optimizer determines the most suitable locations and capacities of DGs and SHCs at the unity load factor and the same locations are used to obtain optimum sizing of DGs and SHCs at other load factors also. The base case data sets consisting of substation apparent power, real power load, reactive power load, real power loss, reactive power loss and minimum node voltage at various load factors in per unit values are taken as input training data for the machine learning model. The optimal sizes of the DGs and SHCs for the corresponding load factors obtained using GWO algorithm are taken as target data sets in per unit values for the machine learning model. An adaptive moment estimation (adam) optimization approach is employed to train the BiLSTM ML model for identifying the ideal values of distributed generations and shunt capacitors at different load factors. The efficacy of the proposed ML-based sizing algorithm is demonstrated via simulation studies.

26 September 2026 in Sustainability
Verified
Journal Article
Open access
PDF file
AAAmarendra Alluri
Amarendra Alluri
Preetham GoliPreetham Goli
Preetham Goli
KJKiran Jasthi
Kiran Jasthi
SGSRINIVASA RAO GAMPA
SRINIVASA RAO GAMPA
MBMahesh Babu Basam
Mahesh Babu Basam
DDDebapriya Das
Debapriya Das
Demand response strategies are widely used by utilities to encourage customers to shift their loads from peak to off-peak periods, thereby offering lower electricity prices. This research proposes a fuzzy multi-objective artificial rabbits optimization (ARO) technique to design the optimal daily load profile of a distribution system under demand response. The daily load profile is partitioned into three zones comprising the left valley, peak period, and right valley. Two load-shifting factors governing the redistribution of peak-period demand between the two valley regions are optimized, ensuring that neither valley load factor exceeds the resulting post-shift peak load factor, while simultaneously accounting for cost-reduction and voltage-performance objectives. Optimally sized distributed generators (DGs) are allocated when demand response alone cannot restore voltage compliance. Simulation results presented for the 69-bus and 123-bus systems demonstrate that shifting load only to the left valley yields a 5.57% energy charge reduction and shifting the load only to the right valley results in a 2.43% reduction. The fuzzy multi-objective solution attains a 4.00% reduction while satisfying the loss and voltage objectives. The minimum voltage of the 69-bus system is restored to 0.95 p.u. with DG, while the 123-bus system complies without DG, and both show reduced daily real power losses. By mitigating peak demand, reducing real power losses, and integrating optimally sized DGs, the proposed method decreases the amount of energy that must be generated and delivered to satisfy the same load demand. In addition, it can defer network reinforcement requirements, thereby enhancing the economic and environmental sustainability of the distribution system.