Debapriya Das

Prof. Dr. Debapriya Das


Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 December 2017 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
AMAvirup Maulik
Avirup Maulik
DDDebapriya Das
Debapriya Das
Recently researchers have focused on the optimal operation of droop-controlled islanded microgrids (DCIMG). However, most of the papers consider only the economic objective. But, with increasing focus on environmental compliance, it has also become necessary to reduce emission from generation activities. Furthermore, most of the previous papers do not consider the heat demand in the microgrid and the uncertainties involved in load and renewable generation forecasting. This paper bridges all these gap areas by presenting a method for determining optimal droop settings of dispatchable distributed generation units in a DCIMG. The objectives are to minimize the operational cost and minimize the emission in the islanded droop-controlled microgrid while meeting all the operational constraints. The proposed formulation takes into account the electricity demand, the heat demand, load uncertainties, and renewable power uncertainties in the microgrid. Load and renewable power uncertainties are modeled by a stochastic scenario based approach. The multiobjective optimization problem is solved using fuzzified particle swarm optimization. The proposed method is validated on a 33-bus DCIMG test system. The results show the effectiveness of the proposed method.

18 June 2018 in IET Renewable Power Generation
Verified
Journal Article
Open access
PDF file
SBSoumyabrata Barik
Soumyabrata Barik
DDDebapriya Das
Debapriya Das
In this study, a methodology for determining the solar and wind DG (distributed generation) capacity is proposed by using sequential optimisation method considering a seasonal variation of load demand, seasonal solar, and wind variations. The load demand profile is collected from state load dispatch centre; whereas solar data are collected from Indian Institute of Technology Kharagpur and wind data are collected from a weather station. Along with the DGs, the shunt capacitors are also placed to improve the voltage profile and energy loss reduction with different scenarios. For this purpose, minimisation of a multi‐objective function is considered. The proposed methodology is applied to a 69‐bus distribution network. The results for different scenarios show the substantial reduction in the annual energy loss and improvement of voltage profile. The result also shows that maximum amount of profit is gained with both renewable DGs and shunt capacitors. The impact of load growth on the distribution network with and without renewable DGs and shunt capacitors are compared. The analysis reveals that with integrating the renewable DGs and shunt capacitors in the system, the distribution network can take load growth for few more years without violating the system constraints.

10 March 1999 in International Journal of Energy Research
Verified
Journal Article
Closed access
PDF file
SAS. K. Aditya
S. K. Aditya
DDDebapriya Das
Debapriya Das
A battery energy storage system (BES) can provide fast active power compensation and hence it also can be used to improve the performance of the load frequency control. In this paper, the study is carried out on a single area model representing the whole power system considering generation rate constraint (GRC). An incremental model of BES is proposed and merged into the load frequency control of the power system. Optimum value of integral gain setting is obtained using integral squared technique (ISE). Dynamic responses of the system are presented with and without considering BES facility. Analysis reveals that BES improves the system performance significantly. Copyright © 1999 John Wiley & Sons, Ltd.

13 March 2023 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
PHPratik Harsh
Pratik Harsh
DDDebapriya Das
Debapriya Das
This letter proposes a two-stage heuristic approach to reconfigure a radial distribution network in the least possible computational time. All the network switches are closed in the initial stage of the operation, and a sequential switch opening strategy is suggested to obtain a near-optimal radial configuration. In the subsequent stage, a pair of switches is selected from the radial network to exchange its ON/OFF status. A mathematical model, using bus injection to branch current matrix, is developed to choose a pair of switches with an objective to reduce the power loss in the network after each exchange operation. The proposed approach is tested on 33-bus, 69-bus, 84-bus, 136-bus, and 417-bus distribution networks, and the results confirm that the suggested methodology helps in achieving the best configuration of the radial distribution networks in a significantly low run-time.

17 May 2018 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
AMAvirup Maulik
Avirup Maulik
DDDebapriya Das
Debapriya Das
This paper proposes a method to determine optimal droop values of dispatchable distributed generation (DG) units in an islanded droop-controlled DC microgrid. Objectives are to minimize fuel cost and maximize small signal stability of the system. In this paper, a detailed state space model of an islanded droop-controlled DC microgrid including the converter, network parameters, and network interconnection is developed. The developed model is then used to obtain the dominant eigen value of the system. Particle swarm optimization is used to determine the optimal droop values of the dispatchable DG units in order to simultaneously reduce the fuel cost, increase system damping, and push the most dominant eigen value away from the imaginary axis to the left of the s-plane. The bi-objective optimization is solved using a fuzzy max-min based approach. The proposed method is validated on a sample 3-bus droopcontrolled DCMG test system. Comparison of the result obtained by the fuzzy max-min approach with that of NSGA-II is also presented in this paper.

16 February 2022 in Smart Cities
Verified
Journal Article
Open access
PDF file
Preetham GoliPreetham Goli
Preetham Goli
KJKiran Jasthi
Kiran Jasthi
SGSRINIVASA RAO GAMPA
SRINIVASA RAO GAMPA
DDDebapriya Das
Debapriya Das
Wajiha ShireenWajiha Shireen
Wajiha Shireen
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
In this study, a two-stage methodology based on the energy savings gained by optimal network reconductoring was developed for the sizing and allocation of electric vehicle (EV) charging load at the residential locations in urban distribution systems. During the first stage, the Flower Pollination Algorithm (FPA) was applied to minimize the annual energy losses of the radial distribution system through optimum network reconductoring. A multi-objective function was formulated to minimize investment, peak loss, and annual energy loss costs at different load factors. The results obtained with the flower pollination algorithm were compared with the particle swarm optimization algorithm. In the second stage, a simple heuristic procedure was developed for the sizing and allocation of EV charging load at every node of the distribution system utilizing part of the annual energy savings obtained by optimal network reconductoring. The number of electric cars, electric bikes, and electric scooters that can be charged at every node was computed while maintaining the voltage and branch current constraints. The simulation results were demonstrated on 123 bus and 51 bus radial distribution networks to validate the effectiveness of the proposed methodology.