Abdulaziz A Alzaid

Dr. Abdulaziz A Alzaid


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 September 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KAKhalid K Alanazi
Khalid K Alanazi
AAAbdulaziz A Alzaid
Abdulaziz A Alzaid
AEAli Elkaffas
Ali Elkaffas
SBSarah Bukhari
Sarah Bukhari
RARamzi O. Althubaitiy
Ramzi O. Althubaitiy
HAHussain Ali AlQahtani
Hussain Ali AlQahtani
The current study aimed to compare the mechanical properties of CAD/CAM fabricated hybrid ceramic restorative materials. The current study assessed the mechanical properties of additively and subtractively manufactured CAD/CAM fabricated hybrid ceramic by conducting flexure strength test, compressive strength test, and Vickers hardness test. Flexural samples were subjected to a three-point bending test using a universal testing machine until the samples showed fracture. Moreover, samples for the compressive strength test were subjected to compression tests using a universal testing machine until samples were fractured. Samples for the Vickers hardness was tested using the Vickers hardness testing machine to determine the sample’s hardness values. There were significant differences (p = 0.0001) were observed among the additive and subtractive groups in terms of flexure strength and compressive strength test. Regarding the Vickers hardness test, significant differences (p = 0.0001) were observed between the polished and unpolished groups in additive manufacturing. However, no significant (p = 0.681) differences were observed in the subtractive manufacturing technique. The subtractive group achieved ISO specifications in terms of flexural strength and was superior to additive groups in hardness while exhibiting lower performance in compressive strength. Moreover, printing orientation had a significant influence on the performance of additive groups. Flexural strength and hardness were improved when the printing orientation was in alignment with the direction of load (90°) while compressive strength was improved when the printing orientation was perpendicular to the direction of load (0°).

Verified
Journal Article
Open access
PDF file
AAAbdulaziz A Alzaid
Abdulaziz A Alzaid
KAKhalid K Alanazi
Khalid K Alanazi
LALulu A. Alyahya
Lulu A. Alyahya
MAMaha N. Alharbi
Maha N. Alharbi
HAHatem Al-qarni
Hatem Al-qarni
GAGhada S Alotaibi
Ghada S Alotaibi
The aim of the study is to assess the impact of mechanical surface treatments on the shear bond strength (SBS) of orthodontic brackets bonded to three-dimensional (3D) printed and milled CAD/CAM provisional materials. Sixty cylindrical samples were fabricated for each provisional material. Samples were treated with one of the following surface treatments: aluminum oxide airborne particle abrasion, diamond bur rotary instrument roughening, and phosphoric acid etching (control). Stainless steel brackets were bonded to the samples, and then SBS was tested using a universal testing machine. SEM and digital microscopy were utilized to examine the bonding interface and the failure modes. Two-way ANOVA, one-way ANOVA, Tukey’s HSD, and independent sample t-tests were used for statistical analysis. Results revealed significant differences in SBS between 3D printed and milled samples and significant differences in SBS among most surface treatments, with rotary instrument roughening resulting in the highest values for 3D printed, while airborne particle abrasion leading for milled samples. Digital microscopy indicated that more adhesive remained on 3D-printed samples. SEM analysis revealed varying surface roughness across treatments. Based on the findings of this study, it can be concluded that different surface treatments improve the bonding of orthodontic brackets to provisional crowns.

5 April 2023 in Heliyon
Verified
Journal Article
Open access
HAHayam Alfallaj
Hayam Alfallaj
FJFaris Z. Jamjoom
Faris Z. Jamjoom
AAAbdulaziz A Alzaid
Abdulaziz A Alzaid
HAHatem Al-qarni
Hatem Al-qarni
Provisional restoration is essential for function, esthetics, occlusion, and tissue health. However, when multiple teeth are involved, making a direct splinted provisional restoration could be challenging due to the combined undercuts between the prepared teeth. This article describes a dental technique using polytetrafluoroethylene (PTFE) tape as a spacer to fabricate a splinted provisional restoration for multiple prepared teeth. The PTFE tape spacer will compensate for discrepancies in the path of insertion between prepared teeth, thus facilitating the removal of the direct splinted provisional restoration intact.

31 March 2024 in Medicina
Verified
Journal Article
Open access
PDF file
AAAbdulaziz AlHelal
Abdulaziz AlHelal
AAAbdulaziz A Alzaid
Abdulaziz A Alzaid
SASaad H. Almujel
Saad H. Almujel
MAMohammed Alsaloum
Mohammed Alsaloum
KAKhalid K Alanazi
Khalid K Alanazi
KAKhulud Al-Aali
Khulud Al-Aali
Background and Objectives: Despite the identified benefits of early implant loading, studies have questioned its advantages compared to delayed loading in edentulous patients. This study aimed to evaluate clinical peri-implant parameters and marginal bone loss around early placed and loaded mandibular implant overdentures with a 60-month follow-up. Materials and Methods: In this prospective cohort study, 43 patients were enrolled to receive 86 early loading sub-crestal dental implants through prosthetic guides. Implant overdentures were supported by two isolated implant locator attachments between two mental foramens. Clinical peri-implant parameters, including plaque index (PI), bleeding index (BI), peri-implant pocket depth (PIPD), and marginal bone loss (MBL) were evaluated using standardized techniques at 1, 12, 24, 36, 48, and 60 months follow-up. At 60 months, complications associated with implant overdentures (IOD’s) were noted. The mean comparison of peri-implant clinical parameters was performed through ANOVA test. A p-value of ≤0.05 was taken as significant. Results: Out of the total 43 enrolled patients, 8 patients were lost during follow-up; as a result, 35 patients completed the 5 years follow-up. The mean values of PI, BI, and PIPD increased with no statistical difference (p > 0.05). For marginal bone loss, an increase in the mean values was noted at different time intervals with statistical differences (p < 0.001). The most common complications noted were loosening of the abutment, occlusal adjustment, retentive locator loosening and replacement, and relining of the denture. Conclusions: Early placement of IODs failed to prevent bone loss over time and was associated with complications, predominantly consisting of abutment loosening, occlusal adjustments, broken retentive locator components, relining, and rebasing.

2 December 2024 in Prosthesis
Verified
Journal Article
Open access
PDF file
AAAbdulaziz A Alzaid
Abdulaziz A Alzaid
SBSarah Bukhari
Sarah Bukhari
MKMathew T. Kattadiyil
Mathew T. Kattadiyil
HAHatem Al-qarni
Hatem Al-qarni
AAAbdulaziz AlHelal
Abdulaziz AlHelal
ESErik F. Sahl
Erik F. Sahl
Background/Objectives: The purpose of this in vitro study was to evaluate and compare the internal adaptation and cement film thickness of cast-gold custom post and core (CPC), three-dimensionally (3D)-printed titanium (Ti) CPC, and milled Ti CPC. Methods: Forty-eight 3D printed resin models, simulating a tooth prepared to receive a CPC, were fabricated. Models were randomly assigned to one of three groups (n = 16 per group): (A) cast-gold CPC (control group), (B) 3D-printed Ti CPC, and (C) milled Ti CPC. Following the manufacturing of CPCs, each CPC was cemented using dual-cure polymerizing resin cement. Then, each model/post-and-core assembly was sectioned at the coronal, middle, and apical thirds of the post at a specific point. Each section was photographed using a microscope in a standardized setting (25×). The pixel count for cement surface area was calculated for each image using Adobe Photoshop software. Descriptive statistics of the mean and standard deviation of the cement film thickness around posts were calculated. Kruskal–Wallis and Dwass–Steel–Critchlow–Fligner tests were used for statistical analysis, with a significance level of α = 0.05. Results: Pairwise comparisons in the coronal section revealed a statistically significant difference (p < 0.05) between groups A and B and groups B and C. In the middle section, there was a statistically significant difference (p < 0.05) between groups A and B only. In the apical section, there was a statistically significant difference (p < 0.05) between all groups. Conclusions: Within the limitation of the present study, neither 3D printed nor milled Ti CPC could achieve comparable cement film thickness to cast-gold CPC in all three sections. Cast-gold CPC cement film thickness was found to be more reduced and consistent, thus having superior internal adaptation to 3D-printed and milled Ti CPCs.

12 December 2024 in Frontiers in Dental Medicine
Verified
Journal Article
Open access
PDF file
AAAbdulaziz A Alzaid
Abdulaziz A Alzaid
KAKhalid K. Alanazi
Khalid K. Alanazi
MAMaha N. Alharbi
Maha N. Alharbi
LALulu A. Alyahya
Lulu A. Alyahya
HAHatem Alqarni
Hatem Alqarni
GAGhada S. Alotaibi
Ghada S. Alotaibi
Introduction: The growing demand for orthodontic treatment in patients irrespective of age highlights the need for effective bonding of brackets to provisional crowns (PCs).Aims and objectives: This study evaluates the shear bond strength (SBS) of orthodontic brackets to 3D-printed and milled PC materials, comparing the effects of hydrofluoric acid (HFA) and phosphoric acid (PA) etching.Materials and methods: Forty cylinders were fabricated using a 3D printer with hybrid resin, and forty were milled from cross-linked polymethyl methacrylate (PMMA) resin. Stainless steel brackets were bonded with light-cured composite resin. Twenty specimens from each group were treated with 9.5% HFA, while the rest of the specimens received 37% PA. Post-bonding, specimens underwent thermocycling and were examined with SEM. SBS testing followed ISO/TS 11405-2015 guidelines. The failure patterns and bond interface were assessed by the Adhesive Remnant Index (ARI) and scanning electron microscopy (SEM). Data was analyzed using ANOVA, Tukey's test.Results: In 3D-printed materials, HFA etching yielded a significantly higher bond strength (12.59 ± 2.64 MPa) than PA etching (7.77 ± 0.83 MPa). The bond strength was inferior in milled materials: HFA (5.98 ± 0.59 MPa) and PA (5.66 ± 0.65 MPa) with no significant difference between both surface treatments. When each material was evaluated separately, a significant difference in SBS was found for surface treatments in 3D-printed materials (p < 0.001) but not for milled materials (p = 0.916). ARI scores showed greater adhesive retention in 3D-printed specimens, particularly those treated with HFA. SEM revealed smoother surfaces in 3D-printed specimens compared to rougher surfaces in milled specimens.Conclusion: HFA etching improves SBS in 3D-printed PC, while in milled materials, the choice of etching agent has minimal effect.