Thomas James Doggett

Dr. Thomas James Doggett

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2017
Verified
Book Chapter
Closed access
TDThomas James Doggett
Thomas James Doggett
RGRonald Greeley
Ronald Greeley
PFPatricio Figueredo
Patricio Figueredo
KTKen Tanaka
Ken Tanaka
Few worlds are as tantalizing and enigmatic as Europa, whose complex icy surface intimates the presence of an ocean below. Europa beckons for our understanding ...

20 August 2006
Verified
Conference Paper
Open access
PDF file
RCRebecca Castano
Rebecca Castano
DMDominic Mazzoni
Dominic Mazzoni
NTNghia Tang
Nghia Tang
RGRon Greeley
Ron Greeley
TDThomas James Doggett
Thomas James Doggett
ADAshley Davies
Ashley Davies

21 October 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
SKSamuel W King
Samuel W King
AAAlexander Abouharb
Alexander Abouharb
TDThomas James Doggett
Thomas James Doggett
MTMohamad Taufiqurrakhman
Mohamad Taufiqurrakhman
JPJeya Palan
Jeya Palan
BDBernard H. van Duren
Bernard H. van Duren
Early diagnosis and treatment of surgical wound infection can be challenging. This is especially relevant in the management of periprosthetic joint infection: early detection is key to success and reducing morbidity, mortality and resource use. ‘Smart’ dressings have been developed to detect parameters suggestive of infection. This scoping review investigates the current status of the field, limited to devices tested in animal models and/or humans, with a focus on their application to arthroplasty. The literature was searched using MEDLINE/PubMed and Embase databases from 2000 to 2023. Original articles assessing external sensing methods for the detection of wound infection in animal models or human participants were included. Sixteen articles were eligible. The results were broadly divided by sensing method: colorimetric, electrochemical and fluorescence/photothermal responses. Six of the devices detected more than one parameter (multimodal), while the rest were unimodal. The most common parameters examined were temperature and pH. Most ‘smart’ dressings focused on diagnosing infection in chronic wounds, and none were tested in humans with wound infections. There is limited late-stage research into using dressing sensors to diagnose wound infection in post-surgical patients. Future research should explore this to enable inpatient and remote outpatient monitoring of post-operative wounds to detect wound infection.

2 February 2024 in Medical Teacher
Verified
Journal Article
Closed access
TDThomas James Doggett
Thomas James Doggett
HWHarriet Warr
Harriet Warr
JJJo-Anne Johnson
Jo-Anne Johnson
SCSimon Cork
Simon Cork

4 January 2024 in Postgraduate Medical Journal
Verified
Journal Article
Closed access
PDF file
TDThomas James Doggett
Thomas James Doggett
CWConnor Way
Connor Way
Bar charts of numerical data, often known as dynamite plots, are unnecessary and misleading. Their tendency to alter the perception of mean’s position through the within-the-bar bias and their lack of information on the distribution of the data are two of numerous reasons. The machine learning tool, Barzooka, can be used to rapidly screen for different graph types in journal articles. We aim to determine the proportion of original research articles using dynamite plots to visualize data, and whether there has been a change in their use over time. Original research articles in nine surgical fields of research were sampled based on MeSH terms and then harvested using the Python-based biblio-glutton-harvester tool. After harvesting, they were analysed using Barzooka. Over 40 000 original research articles were included in the final analysis. The results were adjusted based on previous validation data with 95% confidence bounds. Kendall τ coefficient with the Mann–Kendall test for significance was used to determine the trend of dynamite plot use over time. Eight surgical fields of research showed a statistically significant decrease in use of dynamite plots over 10 years. Oral and maxillofacial surgery showed no significant trend in either direction. In 2022, use of dynamite plots, dependent on field and 95% confidence bounds, ranges from ~30% to 70%. Our results show that the use of dynamite plots in surgical research has decreased over time; however, use remains high. More must be done to understand this phenomenon and educate surgical researchers on data visualization practices. What is already known on this topic Although it is well established that dynamite plots are misleading data visualizations for numerical data, the frequency of their use in surgical research is yet to be investigated. What this study adds Following this study, we now know that dynamite plots are frequently used in most fields of surgical research. Use over time is decreasing; however, more must be done. How this study might affect research, practice or policy This study further reiterates the importance of good data visualizations in research. It also emphasizes the need for educational initiatives for surgeons involved in research, as well as the need for journal policies that encourage better data visualization practices.