Tahasin Ahmed Fahim

Mr. Tahasin Ahmed Fahim

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

13 September 2024 in IEEE Access
Verified
Journal Article
Open access
TFTahasin Ahmed Fahim
Tahasin Ahmed Fahim
FAFatema Binte Alam
Fatema Binte Alam
KAKazi Tanvir Ahmmed
Kazi Tanvir Ahmmed
This paper introduces OVANet, a new deep learning framework for the diagnosis and classification of ovarian cancer subtypes from histopathological images. OVANet has been designed by integrating modified VGG19 and InceptionV3 blocks, incorporating dual attention mechanism (Squeeze-and-Excitation and custom spatial attention) to capture rich, multi-scale, and context-aware feature representations. This unique architecture combines intermediate layers from both base models, along with additional convolutional and max-pooling layers, dual attention mechanisms and global average pooling to extract diverse image features crucial for accurate subtype differentiation. OVANet is trained and evaluated on an original dataset of 508 histopathological images, augmented to approximately 13,024 images through preprocessing and augmentation techniques like rotations, shifts, zooms, and flips. This approach significantly enhances the generalization capabilities of the model, enabling it to achieve superior performance compared to well-known pretrained models and existing research outputs. The propose model shows accuracy, precision and AUC of 99.01% along with a recall of 99.87%. Using feature map visualization of all layers of the model and a model explainibility technique GRADCam, visual representation of classification have been shown which will help to establish transparency in clinical aspect. This architecture can be considered as a significant advancement in medical imaging, especially for the diagnosis and treatment planning of ovarian cancer. To reduce the death rate of cancer, proper detection is very essential and this model exhibits so promising results that can easily implemented clinically.

1 December 2023 in Bulletin of Electrical Engineering and Informatics
Verified
Journal Article
Open access
PDF file
SRSohel Rana
Sohel Rana
TFTahasin Ahmed Fahim
Tahasin Ahmed Fahim
BGBithe Ghosh
Bithe Ghosh
MRMostafizur Rahman
Mostafizur Rahman
In the modern world, wireless technology is one way to send information from one place to another. This technology is getting better and better with time, which significantly impacts the activities that make up daily living. This wireless application has the most impact on mobile and other technologies. This research paper shows the design and analysis of a 3.5 GHz microstrip patch antenna (MPA) for wireless applications. The substrate material is Roggers RT/duroid, which has a dielectric permittivity of 2.2 computer simulation technology (CST) software does antenna design and simulation. Some observed parameters are the S-parameter, antenna directivity gain, voltage standing wave ratio (VSWR), and bandwidth. From the simulation, the return loss, VSWR, directivity gain, and bandwidth are -50.4227, 1.0061, 7.43 dBi, and 122.1 MHz respectively. This study aims to find the best return loss, get the most directional gain, and get the VSWR closer to 1. When this antenna was used, the results were better than those in scientific journals and conferences. As a result, this antenna is anticipated to fulfill the requirements of various wireless communication applications effectively.

11 September 2024 in Information
Verified
Journal Article
Open access
PDF file
FAFatema Binte Alam
Fatema Binte Alam
TFTahasin Ahmed Fahim
Tahasin Ahmed Fahim
MAMd Asef
Md Asef
MHMd. Azad Hossain
Md. Azad Hossain
M. Ali DewanM. Ali Dewan
M. Ali Dewan
Brain tumor detection and categorization of its subtypes are essential for early diagnosis and improving patient outcomes. This research presents a cutting-edge approach that employs advanced data augmentation and deep learning methodologies for brain tumor classification. For this work, a dataset of 6982 MRI images from the IEEE Data Port was considered, in which a total of 5712 images of four classes (1321 glioma, 1339 meningioma, 1595 no tumor, and 1457 pituitary) were used in the training set and a total of 1270 images of the same four classes were used in the testing set. A Wasserstein Generative Adversarial Network was implemented to generate synthetic images to address class imbalance, resulting in a balanced and consistent dataset. A comparison was conducted between various data augmentation metholodogies demonstrating that Wasserstein Generative Adversarial Network-augmented results perform excellently over traditional augmentation (such as rotation, shift, zoom, etc.) and no augmentation. Additionally, a Gaussian filter and normalization were applied during preprocessing to reduce noise, highlighting its superior accuracy and edge preservation by comparing its performance to Median and Bilateral filters. The classifier model combines parallel feature extraction from modified InceptionV3 and VGG19 followed by custom attention mechanisms for effectively capturing the characteristics of each tumor type. The model was trained for 64 epochs using model checkpoints to save the best-performing model based on validation accuracy and learning rate adjustments. The model achieved a 99.61% accuracy rate on the testing set, with precision, recall, AUC, and loss of 0.9960, 0.9960, 0.0153, and 0.9999, respectively. The proposed architecture’s explainability has been enhanced by t-SNE plots, which show unique tumor clusters, and Grad-CAM representations, which highlight crucial areas in MRI scans. This research showcases an explainable and robust approach for correctly classifying four brain tumor types, combining WGAN-augmented data with advanced deep learning models in feature extraction. The framework effectively manages class imbalance and integrates a custom attention mechanism, outperforming other models, thereby improving diagnostic accuracy and reliability in clinical settings.

19 December 2020
Verified
Conference Paper
Closed access
MKMst. Farzana Khatun
Mst. Farzana Khatun
TFTahasin Ahmed Fahim
Tahasin Ahmed Fahim
ASAjay Krishno Sarkar
Ajay Krishno Sarkar
Md. Shamim AnowerMd. Shamim Anower
Md. Shamim Anower
This paper shows total body water (TBW) measurement models for human body based on multivariate regression analysis by non-invasive way. A total number of 1500 people’s data (750 male and 750 female) have been used to develop two models. For developing different model for male and female, two models have been developed.To validate the proposed models some major statistical analysis have been considered. Statistical analysis reports exhibit excellent accuracy i.e. correlation coefficient is close to unity (0.998, 0.997), presence of error within the 95% of Limit of Agreement, less bias (0.03), 0.24) and less RMSE (0.82, 0.69) and hence the proposed models will be able to measure total body water more accurately than existing models.

27 August 2026 in Optics Continuum
Verified
Journal Article
Closed access
TFTahasin Ahmed Fahim
Tahasin Ahmed Fahim
FAFatema Binte Alam
Fatema Binte Alam
Optical coherence tomography (OCT) provides depth-resolved structural information, but estimating dense optical-property maps from intensity data is an ill-conditioned inverse problem. This study presents LA-PG-UNet (localization-aware, prior-guided U-Net), an inclusion-guided and output-consistency-regularized framework evaluated entirely on controlled synthetic OCT-like phantoms. The network estimates the absorption coefficient μ a , the reduced scattering coefficient μ s ′, and a study-defined composite attenuation coefficient μ c = μ a + μ s ′ from a single-channel OCT-like B-scan produced by a phenomenological attenuation, surface-response, roll-off, speckle, and noise generator. A multi-phantom dataset of 1500 samples spans smooth layered, rough multilayer, heterogeneous inclusion, and shifted-parameter noisy conditions. Against a GroupNorm U-Net baseline, LA-PG-UNet reduced inclusion-region μ c mean absolute error (MAE) in all four test partitions (13.63%, 6.80%, 4.43%, 5.36%; all significant after Holm correction) and reduced output-consistency error in all four (significant in three), while the baseline retained lower global μ c MAE—a genuine trade-off between background-dominated full-image reconstruction and localized inclusion recovery. Regional errors for all three coefficients show the inclusion gain is carried almost entirely by μ s ′, with μ a unchanged. A controlled component-wise ablation under shared initialization shows that the output-consistency loss, the inclusion-weighted regression term, the auxiliary branch, and the feature gate each contribute measurably and in different directions, and pixel-level AUROC of 0.74–0.84 indicates coarse but non-random inclusion localization despite low dice. A training-calibrated classical depth-resolved attenuation estimator and a two-output analytical comparator were both outperformed in inclusion-region μ c MAE. All results describe generalization within the synthetic simulator; no experimental OCT or physical-phantom validation is claimed.