In the study, an interrupting performance test on the 145 kV gas circuit breaker is performed according to three different gases: SF6, g3 (5% NovecTM4710 with 95% CO2), and CO2(70%)/O2(30%) gases. Thanks to research advancements, it is confirmed that CO2 and g3 (5% NovecTM 4710) gases, respectively, have 40% and 75% dielectric strength, compared to that of SF6 gas. The filling pressure and transient recovery voltage criteria of each gas were determined differently in order to compare the maximum interrupting performance of each gas. The pressure of SF6 gas was determined to be 5.5 bar, which is typically used in circuit breakers. The pressure of the other two gases was determined to be 8.0 bar (the maximum available pressure of the test circuit breaker) to find the maximum interrupting performance. Moreover, the rate-of-rise of transient recovery voltage of SF6 was determined as 10 kV/μs, which is the value at the state of maximum interrupting performance of the test circuit breaker with SF6. On the other hand, the rate-of-rise of transient recovery voltages of g3 (5% NovecTM4710 with 95% CO2) and CO2(70%)/O2(30%) gases were, respectively, determined as 4∼5 kV/μs to find the interruption available point. The characteristics of arc conductance, arc current, and arc voltage near the current zero, and post-arc current are analyzed to compare the interrupting performance, according to different arc-quenching gases. The arc current is measured using a current transformer (Rogowski coil), and a signal processing method of the arc current and arc voltage is introduced to increase the reliability of the interrupting performance results. As a result of the test, it is confirmed that the critical arc conductance for all test conditions converged within a certain range and the value is around 0.7 mS. In addition, the critical current slope just before the current zero-crossing during the interrupting process is shown to be 1.8 A/μs between interruption success and failure. Consequently, it is verified that the CO2(70%)/O2(30%) mixture and g3 (5% NovecTM4710 with 95% CO2) have a similar arc extinguishing performance and SF6 has a relatively higher extinguishing performance than that of CO2(70%)/O2(30%) mixture and g3 (5% NovecTM4710 with 95% CO2) under the aforementioned filling pressure and TRV conditions.

23 November 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
NSNidhi Sinha
Nidhi Sinha
MSMi-Young Song
Mi-Young Song
HCHyonu Chang
Hyonu Chang
HCHeechol Choi
Heechol Choi
HJHyun-Jae JANG
Hyun-Jae JANG
KSKi-Dong Song
Ki-Dong Song
Electron impact scattering from C3F6O is studied in this work. The R-matrix method was used for the calculations of elastic, momentum transfer, and excitation cross sections. The attachment cross section was obtained through a parametric estimator based on the R-matrix outputs. The Binary-Encounter-Bethe (BEB) method was used for computing the ionization cross section. The obtained cross section set was used for the transport studies using the BOLSIG+ code, which is a two-term Boltzmann equation solver. The present calculation was performed for steady-state Townsend experimental conditions for E/N, covering a range of 100–1000 Td. The critical dielectric strength of pure C3F6O was found to be 475 Td, which is much greater than that of SF6 (355 Td). The effect of the addition of different buffer gases, such as CO2, N2, and O2, was also examined. For the C3F6O–CO2, C3F6O–N2, and C3F6O–O2 mixtures with 65%, 55%, and 60% C3F6O, respectively, the critical dielectric strength was determined to be essentially the same as that of pure SF6. The presence of synergism was confirmed for these gas mixtures. We further derived the Paschen curve using a fitting method with the transport parameters as the basic inputs. The minimum breakdown voltage of C3F6O accounted for only 55% of that of SF6. The buffer gas mixture improved the condition; however, the performance of CO2 and O2 mixtures was not satisfactory. The addition of N2 as the buffer gas significantly improved the breakdown property of the gas. The mixture of ≥99% of N2 or ≤1% of C3F6O gave a better breakdown characteristic than SF6. Any proportion ≥90% of N2 or ≤10% of C3F6O was suitable in the higher pressure ranges. The present work demonstrates the potential of C3F6O as a substitute gas for SF6 with a negligible environmental threat.

1 April 2020 in AIP Advances
Verified
Journal Article
Open access
PDF file
HJHyun-Jae JANG
Hyun-Jae JANG
YOYeon-Ho Oh
Yeon-Ho Oh
KSKi-Dong Song
Ki-Dong Song
YKYoung-Il Kim
Young-Il Kim
The dielectric breakdown properties of dry air, which is widely used as the insulation gas in switchgears of electric distribution systems, are determined for dry-air switchgear analysis and design. In this study, a two-term Boltzmann analysis was applied to investigate the dielectric breakdown properties of dry air with increasing temperatures (300–5000 K) at atmospheric pressure (0.1 MPa). According to the changes in the component ratios of dry air, the collision cross sections of high-mole-fraction decomposition species were considered. In order to analyze the contribution of each dry-air decomposition species to dielectric properties, we compared the dielectric properties calculated with and without considering small amounts of the species, such as Ar and CO2, in actual dry air. The results show that reliable calculations can be obtained for dry air at atmospheric pressure and temperatures up to 5000 K only by considering species with mole fractions exceeding 10−2 in the composition. Based on the calculations, it is observed that the reduced critical dielectric strength of dry air does not significantly change for temperatures up to 2000 K. This means that the dielectric properties of dry air show temperature independence over a wider temperature range than those of SF6.

1 June 2023 in AIP Advances
Verified
Journal Article
Open access
PDF file
HCHyonu Chang
Hyonu Chang
NSNidhi Sinha
Nidhi Sinha
HCHeechol Choi
Heechol Choi
MSMi-Young Song
Mi-Young Song
HJHyun-Jae JANG
Hyun-Jae JANG
KSKi-Dong Song
Ki-Dong Song
To examine the possibility of using a gas molecule as an SF6 alternative gas, the insulation properties of the molecule must be estimated. In this work, we present a theoretical approach to calculate geometry parameters, electron scattering cross sections, and transport properties of nitrogen fluoride oxide (F3NO), which we have selected as an alternative to SF6. The molecular minimum structure of F3NO was optimized using the ɷB97X-D functional combined with the aug-cc-pVTZ basis set. Using this initial geometry obtained by the molecular structure calculation, the R-matrix calculation was done to obtain the elastic and momentum transfer cross section. The BE-f method was used for electronic excitation cross section. For the ionization cross section, the binary encounter Bethe method was used. From the calculated cross section data, the electron transport coefficients and reaction coefficients were calculated by solving the two-term approximated Boltzmann equation to investigate the discharge and insulation characteristics.