In the study, an interrupting performance test on the 145 kV gas circuit breaker is performed according to three different gases: SF, g (5% Novec4710 with 95% CO), and CO(70%)/O(30%) gases. Thanks to research advancements, it is confirmed that CO and g (5% Novec 4710) gases, respectively, have 40% and 75% dielectric strength, compared to that of SF gas. The filling pressure and transient recovery voltage criteria of each gas were determined differently in order to compare the maximum interrupting performance of each gas. The pressure of SF gas was determined to be 5.5 bar, which is typically used in circuit breakers. The pressure of the other two gases was determined to be 8.0 bar (the maximum available pressure of the test circuit breaker) to find the maximum interrupting performance. Moreover, the rate-of-rise of transient recovery voltage of SF was determined as 10 kV/s, which is the value at the state of maximum interrupting performance of the test circuit breaker with SF. On the other hand, the rate-of-rise of transient recovery voltages of g (5% Novec4710 with 95% CO) and CO(70%)/O(30%) gases were, respectively, determined as 4∼5 kV/s to find the interruption available point. The characteristics of arc conductance, arc current, and arc voltage near the current zero, and post-arc current are analyzed to compare the interrupting performance, according to different arc-quenching gases. The arc current is measured using a current transformer (Rogowski coil), and a signal processing method of the arc current and arc voltage is introduced to increase the reliability of the interrupting performance results. As a result of the test, it is confirmed that the critical arc conductance for all test conditions converged within a certain range and the value is around 0.7 mS. In addition, the critical current slope just before the current zero-crossing during the interrupting process is shown to be 1.8 A/s between interruption success and failure. Consequently, it is verified that the CO(70%)/O(30%) mixture and g (5% Novec4710 with 95% CO) have a similar arc extinguishing performance and SF has a relatively higher extinguishing performance than that of CO(70%)/O(30%) mixture and g (5% Novec4710 with 95% CO) under the aforementioned filling pressure and TRV conditions.
15 May 2023 in Computational and Theoretical Chemistry
Electron impact scattering from CFO is studied in this work. The R-matrix method was used for the calculations of elastic, momentum transfer, and excitation cross sections. The attachment cross section was obtained through a parametric estimator based on the R-matrix outputs. The Binary-Encounter-Bethe (BEB) method was used for computing the ionization cross section. The obtained cross section set was used for the transport studies using the BOLSIG+ code, which is a two-term Boltzmann equation solver. The present calculation was performed for steady-state Townsend experimental conditions for E/N, covering a range of 100–1000 Td. The critical dielectric strength of pure CFO was found to be 475 Td, which is much greater than that of SF (355 Td). The effect of the addition of different buffer gases, such as CO, N, and O, was also examined. For the CFO–CO, CFO–N, and CFO–O mixtures with 65%, 55%, and 60% CFO, respectively, the critical dielectric strength was determined to be essentially the same as that of pure SF. The presence of synergism was confirmed for these gas mixtures. We further derived the Paschen curve using a fitting method with the transport parameters as the basic inputs. The minimum breakdown voltage of CFO accounted for only 55% of that of SF. The buffer gas mixture improved the condition; however, the performance of CO and O mixtures was not satisfactory. The addition of N as the buffer gas significantly improved the breakdown property of the gas. The mixture of ≥99% of N or ≤1% of CFO gave a better breakdown characteristic than SF. Any proportion ≥90% of N or ≤10% of CFO was suitable in the higher pressure ranges. The present work demonstrates the potential of CFO as a substitute gas for SF with a negligible environmental threat.
25 November 2024 in IEEE Transactions on Magnetics
This study presents an efficient hybrid mechanical and power electronic (MPE) DC circuit breaker (DCCB) to solve the challenges of conventional hybrid MPE DCCBs. The main branch of the proposed topology reduces on-state losses to a negligible magnitude by utilizing only mechanical switches such as the residual current switch (RCS), fast mechanical switch (FMS), and monostable mechanical switch (MMS). Additionally, it significantly decreases the number of semiconductor devices by employing a series connection between the FMS and the main current breaker (MCB). The DC interruption capability of the proposed hybrid MPE DCCB topology was verified through a simulation based on equivalent electric circuits, and the DC interruption capability of the proposed medium-voltage (MV) class hybrid MPE DCCB was evaluated using a DC interruption test.
30 March 2018 in IEEE Transactions on Plasma Science
This paper represents the prediction of the thermal interruption characteristics of a 72.5-kV CO 2 circuit breaker (CB). An analysis method to simulate CO 2 arc plasma was developed. The principle phenomena of CO 2 arc plasma-nonideal gas behavior, radiative heat transfer (RHT), and nozzle ablation-were considered. In addition, the electric field analysis to compute ohmic heating in the arc region and the analysis of turbulent flows were conducted. The absorption coefficients used in RHT were simplified into mean values of 10 frequency bands to represent the entire absorption spectrum. The proposed method was verified through experimental tests of pressure rise and arc voltage. To predict the thermal interruption characteristics, post arc current (PAC) was computed. PAC is the minute current existing between the contacts of a CB after current zero, and has important value to comprehensively understanding thermal interruption. For comparison, a 72.5-kV CO 2 CB was manufactured and tested, and the results were compared with the results of the thermal interruption tests.
The dielectric breakdown properties of dry air, which is widely used as the insulation gas in switchgears of electric distribution systems, are determined for dry-air switchgear analysis and design. In this study, a two-term Boltzmann analysis was applied to investigate the dielectric breakdown properties of dry air with increasing temperatures (300–5000 K) at atmospheric pressure (0.1 MPa). According to the changes in the component ratios of dry air, the collision cross sections of high-mole-fraction decomposition species were considered. In order to analyze the contribution of each dry-air decomposition species to dielectric properties, we compared the dielectric properties calculated with and without considering small amounts of the species, such as Ar and CO2, in actual dry air. The results show that reliable calculations can be obtained for dry air at atmospheric pressure and temperatures up to 5000 K only by considering species with mole fractions exceeding 10−2 in the composition. Based on the calculations, it is observed that the reduced critical dielectric strength of dry air does not significantly change for temperatures up to 2000 K. This means that the dielectric properties of dry air show temperature independence over a wider temperature range than those of SF6.