Low-cost RGB-D cameras are increasingly being used in several research fields, including human–machine interaction, safety, robotics, biomedical engineering and even reverse engineering applications. Among the plethora of commercial devices, the Intel RealSense cameras have proven to be among the most suitable devices, providing a good compromise between cost, ease of use, compactness and precision. Released on the market in January 2018, the new Intel model RealSense D415 has a wide acquisition range (i.e., ~160–10,000 mm) and a narrow field of view to capture objects in rapid motion. Given the unexplored potential of this new device, especially when used as a 3D scanner, the present work aims to characterize and to provide metrological considerations for the RealSense D415. In particular, tests are carried out to assess the device performance in the near range (i.e., 100–1000 mm). Characterization is performed by integrating the guidelines of the existing standard (i.e., the German VDI/VDE 2634 Part 2) with a number of literature-based strategies. Performance analysis is finally compared against the latest close-range sensors, thus providing a useful guidance for researchers and practitioners aiming to use RGB-D cameras in reverse engineering applications.
Specifically conceived for applications related to face analytics and tracking, scene segmentation, hand/finger tracking, gaming, augmented reality, and RGB-D cameras are nowadays used even as 3-D scanners. Despite depth cameras' accuracy and precision are not comparable with professional 3-D scanners, they still constitute a promising device for reverse engineering (RE) applications in the close range, due to their low cost. This is particularly true for more recent devices, such as, for instance, the RealSense SR300, which promises to be among the best performing close range depth cameras in the market. Given the potentiality of this new device, and since to date a deep investigation on its performances has not been assessed in scientific literature, the main aim of this paper is to characterize and to provide metrological considerations on the Intel RealSense SR300 depth sensor when this is used as a 3-D scanner. To this end, the device sensor performances are first assessed by applying the existing normative guidelines (i.e. the one published by the Association of German Engineers - Verein Deutscher Ingenieure - VDI/VDE 2634) both to a set of raw captured depth data and to a set acquired with optimized setting of the camera. Then, further assessment of the device performances is carried out by applying some strategies proposed in the literature using optimized sensor setting, to reproduce “real life” conditions for the use as a 3-D scanner. Finally, the performance of the device is critically compared against the performance of latest short-range sensors, thus providing a useful guide, for researchers and practitioners, in an informed choice of the optimal device for their own RE application.
Microtia is a congenital malformation affecting one in 5000 individuals and is characterized by physical deformity or absence of the outer ear. Nowadays, surgical reconstruction with autologous tissue is the most common clinical practice. The procedure requires a high level of manual and artistic techniques of a surgeon in carving and sculpting of harvested costal cartilage of the patient to recreate an auricular framework to insert within a skin pocket obtained at the malformed ear region. The aesthetic outcomes of the surgery are highly dependent on the experience of the surgeon performing the surgery. For this reason, surgeons need simulators to acquire adequate technical skills out of the surgery room without compromising the aesthetic appearance of the patient. The current paper aims to describe and analyze the different materials and methods adopted during the history of autologous ear reconstruction (AER) simulation to train surgeons by practice on geometrically and mechanically accurate physical replicas. Recent advances in 3D modelling software and manufacturing technologies to increase the effectiveness of AER simulators are particularly described to provide more recent outcomes.
In brain tumor surgery, an appropriate and careful surgical planning process is crucial for surgeons and can determine the success or failure of the surgery. A deep comprehension of spatial relationships between tumor borders and surrounding healthy tissues enables accurate surgical planning that leads to the identification of the optimal and patient-specific surgical strategy. A physical replica of the region of interest is a valuable aid for preoperative planning and simulation, allowing the physician to directly handle the patient’s anatomy and easily study the volumes involved in the surgery. In the literature, different anatomical models, produced with 3D technologies, are reported and several methodologies were proposed. Many of them share the idea that the employment of 3D printing technologies to produce anatomical models can be introduced into standard clinical practice since 3D printing is now considered to be a mature technology. Therefore, the main aim of the paper is to take into account the literature best practices and to describe the current workflow and methodology used to standardize the pre-operative virtual and physical simulation in neurosurgery. The main aim is also to introduce these practices and standards to neurosurgeons and clinical engineers interested in learning and implementing cost-effective in-house preoperative surgical planning processes. To assess the validity of the proposed scheme, four clinical cases of preoperative planning of brain cancer surgery are reported and discussed. Our preliminary results showed that the proposed methodology can be applied effectively in the neurosurgical clinical practice both in terms of affordability and in terms of simulation realism and efficacy.
By leveraging the recent development of artificial intelligence algorithms, several medical sectors have benefited from using automatic segmentation tools from bioimaging to segment anatomical structures. Segmentation of the musculoskeletal system is key for studying alterations in anatomical tissue and supporting medical interventions. The clinical use of such tools requires an understanding of the proper method for interpreting data and evaluating their performance. The current systematic review aims to present the common bottlenecks for musculoskeletal structures analysis (e.g., small sample size, data inhomogeneity) and the related strategies utilized by different authors. A search was performed using the PUBMED database with the following keywords: deep learning, musculoskeletal system, segmentation. A total of 140 articles published up until February 2022 were obtained and analyzed according to the PRISMA framework in terms of anatomical structures, bioimaging techniques, pre/post-processing operations, training/validation/testing subset creation, network architecture, loss functions, performance indicators and so on. Several common trends emerged from this survey; however, the different methods need to be compared and discussed based on each specific case study (anatomical region, medical imaging acquisition setting, study population, etc.). These findings can be used to guide clinicians (as end users) to better understand the potential benefits and limitations of these tools.
1 October 2018 in Computer Methods and Programs in Biomedicine