Rosa Villa Sanz

Dr. Rosa Villa Sanz

orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2017 in Current Opinion in Electrochemistry
Verified
Journal Article
Closed access
AMAna Moya
Ana Moya
GGGemma Gabriel
Gemma Gabriel
RSRosa Villa Sanz
Rosa Villa Sanz
JCJavier del Campo
Javier del Campo

31 December 2018 in Nature Materials
Verified
Journal Article
Open access
EMEduard Masvidal-Codina
Eduard Masvidal-Codina
XIXavi Illa
Xavi Illa
MDMiguel Dasilva
Miguel Dasilva
ACAndrea Bonaccini Calia
Andrea Bonaccini Calia
TDTanja Dragojevic
Tanja Dragojevic
ABAnton Guimerà Brunet
Anton Guimerà Brunet
Recording infraslow brain signals (<0.1 Hz) with microelectrodes is severely hampered by current microelectrode materials, primarily due to limitations resulting from voltage drift and high electrode impedance. Hence, most recording systems include high-pass filters that solve saturation issues but come hand in hand with loss of physiological and pathological information. In this work, we use flexible epicortical and intracortical arrays of graphene solution-gated field-effect transistors (gSGFETs) to map cortical spreading depression in rats and demonstrate that gSGFETs are able to record, with high fidelity, infraslow signals together with signals in the typical local field potential bandwidth. The wide recording bandwidth results from the direct field-effect coupling of the active transistor, in contrast to standard passive electrodes, as well as from the electrochemical inertness of graphene. Taking advantage of such functionality, we envision broad applications of gSGFET technology for monitoring infraslow brain activity both in research and in the clinic.

1 June 2018 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
AMA. Moya
A. Moya
MRMarti Ortega Ribera
Marti Ortega Ribera
XVXavier Guimerà Villalba
Xavier Guimerà Villalba
ESE. Sowade
E. Sowade
MZMiguel Zea
Miguel Zea
GGGemma Gabriel
Gemma Gabriel
The demand for real-time monitoring of cell functions and cell conditions has dramatically increased with the emergence of organ-on-a-chip (OOC) systems. However, the incorporation of co-cultures and microfluidic channels in OOC systems increases their biological complexity and therefore makes the analysis and monitoring of analytical parameters inside the device more difficult. In this work, we present an approach to integrate multiple sensors in an extremely thin, porous and delicate membrane inside a liver-on-a-chip device. Specifically, three electrochemical dissolved oxygen (DO) sensors were inkjet-printed along the microfluidic channel allowing local online monitoring of oxygen concentrations. This approach demonstrates the existence of an oxygen gradient up to 17.5% for rat hepatocytes and 32.5% for human hepatocytes along the bottom channel. Such gradients are considered crucial for the appearance of zonation of the liver. Inkjet printing (IJP) was the selected technology as it allows drop on demand material deposition compatible with delicate substrates, as used in this study, which cannot withstand temperatures higher than 130 °C. For the deposition of uniform gold and silver conductive inks on the porous membrane, a primer layer using SU-8 dielectric material was used to seal the porosity of the membrane at defined areas, with the aim of building a uniform sensor device. As a proof-of-concept, experiments with cell cultures of primary human and rat hepatocytes were performed, and oxygen consumption rate was stimulated with carbonyl-cyanide-4-(trifluoromethoxy)phenylhydrazone (FCCP), accelerating the basal respiration of 0.23 ± 0.07 nmol s−1/106 cells up to 5.95 ± 0.67 nmol s−1/106 cells s for rat cells and the basal respiration of 0.17 ± 0.10 nmol s−1/106 cells by up to 10.62 ± 1.15 nmol s−1/106 cells for human cells, with higher oxygen consumption of the cells seeded at the outflow zone. These results demonstrate that the approach of printing sensors inside an OOC has tremendous potential because IJP is a feasible technique for the integration of different sensors for evaluating metabolic activity of cells, and overcomes one of the major challenges still remaining on how to tap the full potential of OOC systems.

13 November 2017 in Advanced Functional Materials
Verified
Journal Article
Open access
PDF file
CHClement Hébert
Clement Hébert
EMEduard Masvidal‐Codina
Eduard Masvidal‐Codina
ASAlejandro Suarez‐Perez
Alejandro Suarez‐Perez
ACAndrea Bonaccini Calia
Andrea Bonaccini Calia
GPGaelle Piret
Gaelle Piret
JGJose A. Garrido
Jose A. Garrido
Brain–computer interfaces and neural prostheses based on the detection of electrocorticography (ECoG) signals are rapidly growing fields of research. Several technologies are currently competing to be the first to reach the market; however, none of them fulfill yet all the requirements of the ideal interface with neurons. Thanks to its biocompatibility, low dimensionality, mechanical flexibility, and electronic properties, graphene is one of the most promising material candidates for neural interfacing. After discussing the operation of graphene solution‐gated field‐effect transistors (SGFET) and characterizing their performance in saline solution, it is reported here that this technology is suitable for μ‐ECoG recordings through studies of spontaneous slow‐wave activity, sensory‐evoked responses on the visual and auditory cortices, and synchronous activity in a rat model of epilepsy. An in‐depth comparison of the signal‐to‐noise ratio of graphene SGFETs with that of platinum black electrodes confirms that graphene SGFET technology is approaching the performance of state‐of‐the art neural technologies.

21 January 2013 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
AAAne Altuna
Ane Altuna
EBElisa Bellistri
Elisa Bellistri
ECElena Cid
Elena Cid
PAPaloma Aivar
Paloma Aivar
BGBeatriz Gal
Beatriz Gal
LPLiset Menendez de la Prida
Liset Menendez de la Prida
While novel influential concepts in neuroscience bring the focus to local activities generated within a few tens of cubic micrometers in the brain, we are still devoid of appropriate tools to record and manipulate pharmacologically neuronal activity at this fine scale. Here we designed, fabricated and encapsulated microprobes for simultaneous depth recording and drug delivery using exclusively the polymer SU-8 as structural material. A tetrode- and linear-like electrode patterning was combined for the first time with single and double fluidic microchannels for independent drug delivery. The device was tested experimentally using the in vivo anesthetized rat preparation. Both probe types successfully recorded detailed spatiotemporal features of local field potentials and single-cell activity at a resolution never attained before with integrated fluidic probes. Drug delivery was achieved with high spatial and temporal precision in a range from tens of nanoliters to a few microliters, as confirmed histologically. These technological advancements will foster a wide range of neural applications aimed at simultaneous monitoring of brain activity and delivery at a very precise micrometer scale.

22 December 2021 in Nature Nanotechnology
Verified
Journal Article
Closed access
PDF file
ACAndrea Bonaccini Calia
Andrea Bonaccini Calia
EMEduard Masvidal-Codina
Eduard Masvidal-Codina
TSTrevor M. Smith
Trevor M. Smith
NSNathan Schäfer
Nathan Schäfer
DRDaman Rathore
Daman Rathore
JGJose A. Garrido
Jose A. Garrido