Lingqian Zhang

Dr. Lingqian Zhang

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 September 2021 in The Analyst
Verified
Journal Article
Closed access
PDF file
WZWenjie Zhao
Wenjie Zhao
LZLingqian Zhang
Lingqian Zhang
YYYifei Ye
Yifei Ye
YLYuang Li
Yuang Li
XLXiaofeng Luan
Xiaofeng Luan
Chengjun HuangChengjun Huang
Chengjun Huang
Tumor-derived exosomes have been recognized as potential biomarkers for cancer diagnosis because they are actively involved in cancer progression and metastasis. However, progress in practical exosome analysis is still slow due to the limitation in exosome isolation and detection. The development of microfluidic devices has provided a promising analytical platform compared with traditional methods. In this study, we develop an exosome isolation and detection method based on a microfluidic device (ExoDEP-chip), which realized microsphere mediated dielectrophoretic isolation and immunoaffinity detection. Exosomes were firstly isolated by binding to antibodies pre-immobilized on the polystyrene (PS) microsphere surface and were further detected using fluorescently labeled antibodies by fluorescence microscopy. Single microspheres were then trapped into single microwells under the DEP force in the ExoDEP-chip. A wide range from 1.4 × 103 to 1.4 × 108 exosomes per mL with a detection limit of 193 exosomes per mL was obtained. Through monitoring five proteins (CD81, CEA, EpCAM, CD147, and AFP) of exosomes from three different cell lines (A549, HEK293, and HepG2), a significant difference in marker expression levels was observed in different cell lines. Therefore, this method has good prospects in exosome-based tumor marker detection and cancer diagnosis.

14 August 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
CJCheng Jie
Cheng Jie
Yang LiuYang Liu
Yang Liu
YZYang Zhao
Yang Zhao
LZLina Zhang
Lina Zhang
LZLingqian Zhang
Lingqian Zhang
Chengjun HuangChengjun Huang
Chengjun Huang
Circulating tumor cells (CTCs), a type of cancer cell that spreads from primary tumors into human peripheral blood and are considered as a new biomarker of cancer liquid biopsy. It provides the direction for understanding the biology of cancer metastasis and progression. Isolation and analysis of CTCs offer the possibility for early cancer detection and dynamic prognosis monitoring. The extremely low quantity and high heterogeneity of CTCs are the major challenges for the application of CTCs in liquid biopsy. There have been significant research endeavors to develop efficient and reliable approaches to CTC isolation and analysis in the past few decades. With the advancement of microfabrication and nanomaterials, a variety of approaches have now emerged for CTC isolation and analysis on microfluidic platforms combined with nanotechnology. These new approaches show advantages in terms of cell capture efficiency, purity, detection sensitivity and specificity. This review focuses on recent progress in the field of nanotechnology-assisted microfluidics for CTC isolation and detection. Firstly, CTC isolation approaches using nanomaterial-based microfluidic devices are summarized and discussed. The different strategies for CTC release from the devices are specifically outlined. In addition, existing nanotechnology-assisted methods for CTC downstream analysis are summarized. Some perspectives are discussed on the challenges of current methods for CTC studies and promising research directions.

16 September 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
YYYifei Ye
Yifei Ye
XLXiaofeng Luan
Xiaofeng Luan
LZLingqian Zhang
Lingqian Zhang
WZWenjie Zhao
Wenjie Zhao
CJCheng Jie
Cheng Jie
Chengjun HuangChengjun Huang
Chengjun Huang
The electroporation system can serve as a tool for the intracellular delivery of foreign cargos. However, this technique is presently limited by the inaccurate electric field applied to the single cells and lack of a real-time electroporation metrics subsystem. Here, we reported a microfluidic system for precise and rapid single-cell electroporation and simultaneous impedance monitoring in a constriction microchannel. When single cells (A549) were continuously passing through the constriction microchannel, a localized high electric field was applied on the cell membrane, which resulted in highly efficient (up to 96.6%) electroporation. During a single cell entering the constriction channel, an abrupt impedance drop was noticed and demonstrated to be correlated with the occurrence of electroporation. Besides, while the cell was moving in the constriction channel, the stabilized impedance showed the capability to quantify the electroporation extent. The correspondence of the impedance variation and electroporation was validated by the intracellular delivery of the fluorescence indicator (propidium iodide). Based on the obtained results, this system is capable of precise control of electroporation and real-time, label-free impedance assessment, providing a potential tool for intracellular delivery and other biomedical applications.

11 March 2023 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
FWFei Wang
Fei Wang
XLXin Li
Xin Li
SWSiyuan Wang
Siyuan Wang
YCYitao Cao
Yitao Cao
LZLingqian Zhang
Lingqian Zhang
CHChengjun Huang
Chengjun Huang

2 April 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
LZLingqian Zhang
Lingqian Zhang
YLYaoping Liu
Yaoping Liu
ZLZhihong Li
Zhihong Li
Wei WangWei Wang
Wei Wang
Parylene C is a widely used polymer material in microfabrication because of its excellent properties such as chemical inertness, biocompatibility and flexibility. It has been commonly adopted as a structural material for a variety of microfluidics and bio-MEMS (micro-electro-mechanical system) applications. However, it is still difficult to achieve a controllable Parylene C pattern, especially on film thicker than a couple of micrometers. Here, we proposed an SF6 optimized O2 plasma etching (SOOE) of Parylene C, with titanium as the etching mask. Without the SF6, noticeable nanoforest residuals were found on the O2 plasma etched Parylene C film, which was supposed to arise from the micro-masking effect of the sputtered titanium metal mask. By introducing a 5-sccm SF6 flow, the residuals were effectively removed during the O2 plasma etching. This optimized etching strategy achieved a 10 μm-thick Parylene C etching with the feature size down to 2 μm. The advanced SOOE recipes will further facilitate the controllable fabrication of Parylene C microstructures for broader applications.

23 December 2020 in Langmuir
Verified
Journal Article
Closed access
XLXin Li
Xin Li
YZYijun Zhang
Yijun Zhang
MLMingxiao Li
Mingxiao Li
YZYang Zhao
Yang Zhao
LZLingqian Zhang
Lingqian Zhang
CHChengjun Huang
Chengjun Huang