This paper presents a positive approach in an optimized design of a combinatory unified power-quality conditioner (UPQC) and superconducting fault current limiters (SFCLs). This is based on a normalized simulated annealing algorithm compared with analytic hierarchy process objective optimization. The optimization algorithm for simultaneous optimization computes and produces three-dimensional alignments in Pareto front at the end of the optimization run. The results show that the SFCL can reduce the volt-ampere rating of the UPQC by limiting the fault current, thereby reducing the cost of UPQC installation. The aforementioned algorithm requires advanced numerical techniques for simulation studies by PSCAD/EMTDC on a sample distribution system for determining a global optimal combination of UPQC and SFCL by considering individual parameters and accounting for the constraints, which is the main motivation of this paper. This will result in a more thorough knowledge of “scaling factors” and the system quality mechanism which will enable the most efficient systems from the viewpoints of cost cutting, energy savings, and downsizing.
4 September 2009 in IEEE Transactions on Electromagnetic Compatibility
The electromagnetic environment within a substation is very complex. Substations represent an intricate interconnected collection of devices that serve as electromagnetic wave emitters and receptors. Transient electromagnetic emissions-electromagnetic interference (EMI)-are generated during the switching of disconnector and circuit breakers (CBs) that may cause malfunction or damage to electronic equipment positioned nearby if appropriate immunity measures are not taken. The interference may couple significant energy through common-mode currents to cable protection. Electromagnetic compatibility is mostly achieved by addressing the EMI victim through techniques in the secondary environment, such as shielding and filtering. This paper presents the finite-element method analysis of three methods: metallic channel, braided cable, and additional cable, used for EMI mitigation on low-voltage cables of 20 kV side in a 63-kV/20-kV substation due to switching effects of disconnector and CBs. In each method, overvoltage is considered and the results are compared with each other. A simple circuit analysis was also carried out on the causes of switching based on EMI to provide some insight into the interference mechanism during switching process, using common-mode and differential-mode equivalent circuits. The overvoltage reductions are attained through differential-mode current and shielding methods.
1 April 2016 in IEEE Transactions on Applied Superconductivity
The basic concept of superconductive magnetic gears (SMGs) is to maximize the benefits and impact of the magnetic gearing technology by highlighting the future perspective of SMGs to produce a more efficient and compact system. This paper deals with a new analytical method (AM) for the calculation of magnetic field distribution in an SMG. A 2-D AM based on Laplace's partial differential equations of magnetic scalar potential in the different subdomains of a magnetic gear is introduced and solved by considering the corresponding boundary conditions. The proposed method shows a significant reduction in the consumed calculation time compared with the finite-element method (FEM) and can be used as a basis for design optimizations. Two-dimensional AM results are compared against those obtained from 2-D FEM simulations, using an accurate, yet efficient, high-temperature superconductor (HTS) modeling, yielded by a detailed localized $E{-}J$ power law approach combining the different aspects of HTS in a numerical method, so as to find out the benefits and validity of the presented AM. Finally, the effects of PMs and pole pieces' dimensions on torque density are realized.
29 November 2010 in IEEE Transactions on Applied Superconductivity
The superconducting magnetic energy storage (SMES) system technology has the potential to bring real power storage characteristic to the utility transmission and distribution systems. The principal object of this paper is to provide a positive approach in an optimized design of a SMES solenoid coil, ensuring the desired energy storage capacity based on the normalized simulated annealing (SA) algorithm. The optimization algorithm for simultaneous optimization computes and produces 2-D alignments in the Pareto front at the end of the optimization run. The optimization process of the normalized SA algorithm is verified by another strategy algorithm, i.e., the nondominant sorting genetic algorithm. In both strategies, simultaneous optimization will show a set of feasible solutions in Pareto optimality in SMES solenoids. Hence, this requires field analysis for verification of the Pareto optimality design. Moreover, to provide inadequate free space surrounding the area where stray field reduction is desired, aiming simultaneously at compactness and efficiency of the SMES system (the approach of a stray field cancellation (active shielding) scheme by modeling multiparallel solenoids), is a further object of this paper.
The main limitation of magnetic gears is their relatively low torque density. Therefore, a novel structured high torque density magnetic-geared permanent magnet (MGPM) machine, which combines the advantages of a conventional MGPM machine and magnetic gear to enhance the torque considerably and achieve low-speed high-torque operation, is proposed in this study. However, there are different structures for increasing torque of a machine. Therefore, in order to demonstrate the advantages of the proposed structure, it is compared with other structures, using the finite element method. Moreover, the proposed MGPM machine can transmit an additional 42.3% of torque density when compared with the conventional MGPM machine of the same size.
1 January 2008 in Progress In Electromagnetics Research