Dileep Kumar

Mr. Dileep Kumar


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2024 in Energies
Verified
Journal Article
Open access
PDF file
DKDileep Kumar
Dileep Kumar
Wajiha ShireenWajiha Shireen
Wajiha Shireen
NRNanik Ram
Nanik Ram
Over the past few decades, wind energy has expanded to become a widespread, clean, and sustainable energy source. However, integrating offshore wind energy with the onshore AC grids presents many stability and control challenges that hinder the reliability and resilience of AC grids, particularly during faults. To address this issue, current grid codes require offshore wind farms (OWFs) to remain connected during and after faults. This requirement is challenging because, depending on the fault location and power flow direction, DC link over- or under-voltage can occur, potentially leading to the shutdown of converter stations. Therefore, this necessitates the proper understanding of key technical concepts associated with the integration of OWFs. To help fill the gap, this article performs an in-depth investigation of existing alternating current fault ride through (ACFRT) techniques of modular multilevel converter-based high-voltage direct current (MMC-HVDC) for OWFs. These techniques include the use of AC/DC choppers, flywheel energy storage devices (FESDs), power reduction strategies for OWFs, and energy optimization of the MMC. This article covers both scenarios of onshore and offshore AC faults. Given the importance of wind turbines (WTs) in transforming wind energy into mechanical energy, this article also presents an overview of four WT topologies. In addition, this article explores the advanced converter topologies employed in HVDC systems to transform three-phase AC voltages to DC voltages and vice versa at each terminal of the DC link. Finally, this article explores the key stability and control concepts, such as small signal stability and large disturbance stability, followed by future research trends in the development of converter topologies for HVDC transmission such as hybrid HVDC systems, which combine current source converters (CSCs) and voltage source converters (VSCs) and diode rectifier-based HVDC (DR-HVDC) systems.

30 September 2026 in Energies
Verified
Journal Article
Open access
PDF file
DKDileep Kumar
Dileep Kumar
Wajiha ShireenWajiha Shireen
Wajiha Shireen
The Modular Multilevel Converter-based High-Voltage Direct Current (MMC-HVDC) system has emerged as a promising technology to integrate offshore wind farms (OWFs). However, onshore AC faults and resulting DC-link voltage escalation can challenge the reliability of MMC-HVDC systems. This paper proposes an integrated dual energy control with energy dissipation scheme (DEC-EDS) to improve the AC fault ride-through (FRT) in OWF MMC-HVDC systems. The proposed DEC-EDS scheme leverages the short-term overload capacity of MMC half-bridge submodule (SM) capacitors to store part of the surplus power during onshore AC faults while dissipating any excess power into a DC energy dissipation device (EDD). During fault conditions, the MMC SM capacitors and the DC EDD operate in parallel to manage surplus energy, with the capacitors providing temporary buffering and the EDD dissipating the excess power. The proposed scheme is tested on a ±320 kV/420 MW MMC-HVDC system. The results show that the proposed control scheme effectively maintains DC-link voltages, ensuring the connection of OWFs.

22 November 2025 in arXiv
Verified
Preprint
Open access
PDF file
DKDileep Kumar
Dileep Kumar
Wajiha ShireenWajiha Shireen
Wajiha Shireen
Modular Multilevel Converter-based High Voltage Direct Current (MMC-HVDC) system is a promising technology for integration of offshore wind farms (OWFs). However, onshore AC faults on MMC-HVDC reduce the power transfer capability of onshore converter station, leading to surplus power accumulation in HVDC link. This surplus power causes a rapid rise in DC-link voltage and may hinder safe operation of OWFs. To address such a situation, this paper presents an AC fault ride-through scheme that combines the storage of surplus power in MMC submodule (SM) capacitors and dissipation of residual power in an energy dissipation device (EDD). The proposed energy control facilitates use of half-bridge MMC SMs with low-capacitance, with their storage capacity leveraged to share the surplus power during faults, with a lower-rated EDD. The proposed scheme is tested on a 640kV/420MW MMC-HVDC system. The results show that proposed control scheme effectively maintains DC link voltages, ensuring connection of OWFs.