MAGRUR KAZAK

MAGRUR KAZAK


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2016 in The Open Dentistry Journal
Verified
Journal Article
Open access
PDF file
DÖDidem Öner Özdaş
Didem Öner Özdaş
MKMAGRUR KAZAK
MAGRUR KAZAK
AÇAylin Çilingir
Aylin Çilingir
MSMeryem Gülce Subaşı
Meryem Gülce Subaşı
MTMurat Tiryaki
Murat Tiryaki
ŞGŞölen Günal
Şölen Günal
Background: Although most of the studies investigated color stability of different restorative materials, evaluation of color stability of composites after immersion in multiple beverages in the same day by anin vitrooral simulation study is unclear.Objective: To assess color change of different restorative materials at the end of days 1, 14, and 30 of immersion in multiple liquid types to mimic the oral environmentin vitro.Method: Ten disc-shaped specimens were made from each of four different resin composites (Filtek Z250, Voco x-tra base, Beautifil Flow Plus, Beautifil II). Baseline color value of each sample was measured using a spectrophotometer. Each composite was respectively immersed in coffee, an orange/pomegranate juice mixture, black tea, and a mouth rinse on the same day to mimic daily liquid consumption of individuals. Color measurements were taken after 1, 14, and 30 days by spectrophotometer and color change values were calculated. Statistical analyses were executed by one-way ANOVA/Tukey HSD and repeated-measures ANOVA.Results: All materials showed significant color change after 1, 14, and 30 days (P< 0.01) of immersion in liquids, with the lowest color alteration observed at the 1stday and the highest observed after the 30thday. Among the materials tested, at each time point (1, 14, and 30 days), the lowest color alteration was detected in Filtek Z250 and the highest color alteration was detected in Beautifil II.Conclusion: Color alteration of composite resins is affected by composite type and storage time. With the exception of 1 day of storage, color changes of all materials were substantial and clinically unacceptable.

1 January 2020 in Journal of Applied Oral Science
Verified
Journal Article
Open access
PDF file
BOBurcu oglakci ozkoc
Burcu oglakci ozkoc
MKMAGRUR KAZAK
MAGRUR KAZAK
NDNazmiye Donmez
Nazmiye Donmez
EDEvrim Eliguzeloglu Dalkilic
Evrim Eliguzeloglu Dalkilic
SKSafiye Selin Koymen
Safiye Selin Koymen
Gap formation of composite resin restorations is a serious shortcoming in clinical practice. Polymerization shrinkage stress exceeds the tooth-restoration bond strength, and it causes bacterial infiltration within gaps between cavity walls and the restorative material. Thus, an intermediate liner application with a low elastic modulus has been advised to minimize polymerization shrinkage as well as gap formation. The purpose of this in vitro study was to assess gap formation volume in premolars restored with different bulk-fill composites, with and without a resin-modified glass-ionomer cement (RMGIC) liner, using x-ray micro-computed tomography (micro-CT). Sixty extracted human maxillary premolars were divided into six groups according to bucco-palatal dimensions (n=10). Standardized Class II mesio-occluso-distal cavities were prepared. G-Premio Bond (GC Corp., Japan) was applied in the selective-etch mode. Teeth were restored with high-viscosity (Filtek Bulk Fill, 3M ESPE, USA)-FB, sonic-activated (SonicFill 2, Kerr, USA)-SF and low viscosity (Estelite Bulk Fill Flow, Tokuyama, Japan)-EB bulk-fill composites, with and without a liner (Ionoseal, Voco GmbH, Germany)-L. The specimens were subjected to 10,000 thermocycles (5-55°C) and 50,000 simulated chewing cycles (100 N). Gap formation based on the volume of black spaces at the tooth-restoration interface was quantified in mm3 using micro-computed tomography (SkyScan, Belgium), and analyses were performed. Data were analyzed using repeated-measures ANOVA and the Bonferroni correction test (p < 0.05). The gap volume of all tested bulk-fill composites demonstrated that Group SF (1.581±0.773) had significantly higher values than Group EB (0.717±0.679). Regarding the use of a liner, a significant reduction in gap formation volume was observed only in Group SFL (0.927±0.630) compared with Group SF (1.581±0.773). It can be concluded that different types of bulk-fill composite resins affected gap formation volume. Low-viscosity bulk-fill composites exhibited better adaptation to cavity walls and less gap formation than did sonic-activated bulk-fill composites. The use of an RMGIC liner produced a significant reduction in gap formation volume for sonic-activated bulk-fill composites.

22 January 2019 in BioMed Research International
Verified
Journal Article
Open access
PDF file
EDEvrim Eliguzeloglu Dalkılıç
Evrim Eliguzeloglu Dalkılıç
MKMAGRUR KAZAK
MAGRUR KAZAK
DHDuygu Hisarbeyli
Duygu Hisarbeyli
MFMehmet Ali Fildisi
Mehmet Ali Fildisi
NDNazmiye Donmez
Nazmiye Donmez
HAHacer Deniz Arısu
Hacer Deniz Arısu
Objective.The aim of this study is to evaluate the effects of different fiber insertion techniques and thermomechanical aging on the fracture resistance of endodontically treated mandibular premolar teeth restored using bulk-fill composites.Materials and Methods. Eighty human mandibular premolar teeth were randomly divided into eight groups: Group IN, Group BF, Group PRF1, Group PRF2, Group IN-TMA, Group BF-TMA, Group PRF1-TMA ,and Group PRF2-TMA. Group IN (intact) and Group IN-TMA (intact but subjected to thermomechanical aging) served as control groups. In the other six groups, endodontic treatment was performed and standardized mesio-occluso-distal (MOD) cavities were prepared. In BF, PRF1, and PRF2, the cavities were restored with bulk-fill composite only, bulk-fill/Ribbond, and bulk-fill/additional Ribbond, respectively. In BF-TMA, PRF1-TMA, and PRF2-TMA, the teeth were subjected to thermomechanical aging after the restorations. All of the teeth were fractured on the universal testing machine. Fracture surfaces were analyzed with a stereomicroscope.Results.Control groups showed significantly higher fracture strengths than tested groups (P0.05). Most of the favorable fractures were seen in PRF1, PRF2, and PRF2-TMA. Most of the unfavorable fractures were seen in BF-TMA.Conclusions. Although fiber insertion with different techniques did not increase the fracture strength of teeth restored with bulk-fill composites, it increased the favorable fracture modes. Thermomechanical aging did not change the fracture strength of the groups.

18 September 2024 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
MKMAGRUR KAZAK
MAGRUR KAZAK
TATugba Toz Akalin
Tugba Toz Akalin
MEM.Fevzi Esen
M.Fevzi Esen
Objectives This study aimed to investigate and compare water sorption and solubility properties of current restorative materials with different contents. Materials and Methods Alkasite, self-adhesive restorative material (Cention N, Ivoclar Vivadent AG, Schaan, Liechtenstein), bulk-fill glass hybrid restorative material (EQUIA Forte HT, GC Corp., Tokyo, Japan), nanohybrid universal composite material (OptiShade, Kerr Dental, United States), and bulk-fill composite material (Filtek One Bulk Fill Restorative, 3M ESPE, St. Paul, Minnesota, United States) were used. Samples (n = 6) were prepared (2 × 10 mm) according to the ISO 4049 standards. Water sorption and solubility values were calculated according to the ISO 4049 standards. Statistical Analysis One-way ANOVA, Tukey's post-hoc, Tamhane's T2 post-hoc, Pearson's correlation, and independent samples t-tests were used for statistical analysis (p < 0.05). Results Group EQUIA Forte HT significantly showed the highest water sorption values (57.278 ± 3.174), while Group Filtek One Bulk Fill Restorative exhibited the lowest (4.429 ± 0.174; p < 0.05). The water sorption values for Group Cention N were 5.000 ± 0.542. Group EQUIA Forte HT significantly had the lowest water solubility values (−99.799 ± 1.909), while Group Cention N (−2.966 ± 0.402) significantly exhibited the highest (p < 0.05). There was no significant correlation between water sorption and solubility values for each material (p > 0.05). Conclusion The bulk-fill nano-filled composite resin material was successful in terms of water sorption while the bulk-fill glass hybrid restorative system in terms of water solubility. Alkasite can be recommended to be used as a base material due to its high solubility feature. Monomer, filler type, and amount had an impact on the water sorption and solubility properties of the tested materials.

2 June 2019 in Scanning
Verified
Journal Article
Open access
PDF file
ZÖZümrüt Ceren Özduman
Zümrüt Ceren Özduman
MKMAGRUR KAZAK
MAGRUR KAZAK
MFMehmet Ali Fildisi
Mehmet Ali Fildisi
RÖRümeysa Hatice Özlen
Rümeysa Hatice Özlen
EDEvrim Dalkilic
Evrim Dalkilic
NDNazmiye Donmez
Nazmiye Donmez
Objective. The aim of this study is to evaluate the microhardness and surface roughness of two different bulk-fill composites polymerized with light-curing unit (LCU) with different polymerization times before and after the application of a home bleaching agent.Materials-Methods. For both microhardness and surface roughness tests, 6 groups were prepared with bulk-fill materials (SonicFill, Filtek Bulk Fill) according to different polymerization times (10, 20, and 30 s). 102 specimens were prepared using Teflon molds (4 mm depth and 5 mm diameter) and polymerized with LCU. 30 specimens (n=5) were assessed for microhardness. Before home bleaching agent application, the bottom/top (B/T) microhardness ratio was evaluated. After bleaching agent application, the microhardness measurements were performed on top surfaces. Roughness measurements were performed in 72 specimens (n=12) before and after bleaching application. Additionally, for SEM analyses, two specimens from all tested groups were prepared before and after bleaching agent application. The data B/T microhardness ratio before bleaching was analyzed by two-way ANOVA and Tukey’s HSD test. The data from the top surface of specimens’ microhardness before and after bleaching were analyzed using Wilcoxon signed-rank test, Kruskal-Wallis, Mann-WhitneyUtests. The data from surface roughness tests were statistically analyzed by multivariate analysis of variance and Bonferroni test (p<0.05).Results. The B/T microhardness ratio results revealed no significant differences between groups (p>0.05). Comparing the microhardness values of the composites’ top surfaces before and after bleaching, a significant decrease was observed exclusively in FB30s (p<0.05). No significant differences in surface roughness values were observed when the groups were compared based on bulk-fill materials (p>0.05) while the polymerization time affected the surface roughness of the SF20s and SF30s groups (p<0.05). After bleaching, surface roughness values were significantly increased in the SF20s and SF30s groups (p<0.05).Conclusion. The clinicians should adhere to the polymerization time recommended by the manufacturer to ensure the durability of the composite material in the oral environment.

30 October 2019 in Bezmialem Science
Verified
Journal Article
Closed access
MKMAGRUR KAZAK
MAGRUR KAZAK
NDNazmiye Dönmez
Nazmiye Dönmez