Zümrüt Ceren Özduman

Mrs. Zümrüt Ceren Özduman


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2023 in Polymers
Verified
Journal Article
Open access
PDF file
ZÖZümrüt Ceren Özduman
Zümrüt Ceren Özduman
BOBurcu oglakci ozkoc
Burcu oglakci ozkoc
DBDerya Merve Halacoglu Bagis
Derya Merve Halacoglu Bagis
BTBinnur Aydogan Temel
Binnur Aydogan Temel
EDEvrim Eliguzeloglu Dalkilic
Evrim Eliguzeloglu Dalkilic
The aim of this study was a comprehensive evaluation and comparison of the physical and mechanical properties of a newly developed nano-sized hydroxyapatite fiber-reinforced composite with other fiber-reinforced and particle-filled composites. Commercially available eight composite resins (3 fiber-reinforced and 5 particle-filled) were used: Fiber-reinforced composites: (1) NovaPro Fill (Nanova): newly developed nano-sized hydroxyapatite fiber-reinforced composite (nHAFC-NF); (2) Alert (Pentron): micrometer-scale glass fiber-reinforced composite (µmGFC-AL); (3) Ever X Posterior (GC Corp): millimeter-scale glass fiber-reinforced composite (mmGFC-EX); Particle-filled composites: (4) SDR Plus (Dentsply) low-viscosity bulk-fill (LVBF-SDR); (5) Estelite Bulk Fill (Tokuyama Corp.) low-viscosity bulk-fill (LVBF-EBF); (6) Filtek Bulk Fill Flow (3M ESPE) low-viscosity bulk-fill (LVBF-FBFF); (7) Filtek Bulk Fill (3M ESPE) high-viscosity bulk-fill (HVBF-FBF); and (8) Filtek Z250 (3M ESPE): microhybrid composite (µH-FZ). For Vickers microhardness, cylindrical-shaped specimens (diameter: 4 mm, height: 2 mm) were fabricated (n = 10). For the three-point bending test, bar-shaped (2 × 2 × 25 mm) specimens were fabricated (n = 10). Flexural strength and modulus elasticity were calculated. AcuVol, a video image device, was used for volumetric polymerization shrinkage (VPS) evaluations (n = 6). The polymerization degree of conversion (DC) was measured on the top and bottom surfaces with Fourier Transform Near-Infrared Spectroscopy (FTIR; n = 5). The data were statistically analyzed using one-way ANOVA, Tukey HSD, Welsch ANOVA, and Games–Howell tests (p < 0.05). Pearson coefficient correlation was used to determine the linear correlation. Group µH-FZ displayed the highest microhardness, flexural strength, and modulus elasticity, while Group HVBF-FBF exhibited significantly lower VPS than other composites. When comparing the fiber-reinforced composites, Group mmGFC-EX showed significantly higher microhardness, flexural strength, modulus elasticity, and lower VPS than Group nHAFC-NF but similar DC. A strong correlation was determined between microhardness, VPS and inorganic filler by wt% and vol% (r = 0.572–0.877). Fiber type and length could affect the physical and mechanical properties of fibers containing composite resins.

2 June 2019 in Scanning
Verified
Journal Article
Open access
PDF file
ZÖZümrüt Ceren Özduman
Zümrüt Ceren Özduman
MKMAGRUR KAZAK
MAGRUR KAZAK
MFMehmet Ali Fildisi
Mehmet Ali Fildisi
RÖRümeysa Hatice Özlen
Rümeysa Hatice Özlen
EDEvrim Dalkilic
Evrim Dalkilic
NDNazmiye Donmez
Nazmiye Donmez
Objective. The aim of this study is to evaluate the microhardness and surface roughness of two different bulk-fill composites polymerized with light-curing unit (LCU) with different polymerization times before and after the application of a home bleaching agent.Materials-Methods. For both microhardness and surface roughness tests, 6 groups were prepared with bulk-fill materials (SonicFill, Filtek Bulk Fill) according to different polymerization times (10, 20, and 30 s). 102 specimens were prepared using Teflon molds (4 mm depth and 5 mm diameter) and polymerized with LCU. 30 specimens (n=5) were assessed for microhardness. Before home bleaching agent application, the bottom/top (B/T) microhardness ratio was evaluated. After bleaching agent application, the microhardness measurements were performed on top surfaces. Roughness measurements were performed in 72 specimens (n=12) before and after bleaching application. Additionally, for SEM analyses, two specimens from all tested groups were prepared before and after bleaching agent application. The data B/T microhardness ratio before bleaching was analyzed by two-way ANOVA and Tukey’s HSD test. The data from the top surface of specimens’ microhardness before and after bleaching were analyzed using Wilcoxon signed-rank test, Kruskal-Wallis, Mann-WhitneyUtests. The data from surface roughness tests were statistically analyzed by multivariate analysis of variance and Bonferroni test (p<0.05).Results. The B/T microhardness ratio results revealed no significant differences between groups (p>0.05). Comparing the microhardness values of the composites’ top surfaces before and after bleaching, a significant decrease was observed exclusively in FB30s (p<0.05). No significant differences in surface roughness values were observed when the groups were compared based on bulk-fill materials (p>0.05) while the polymerization time affected the surface roughness of the SF20s and SF30s groups (p<0.05). After bleaching, surface roughness values were significantly increased in the SF20s and SF30s groups (p<0.05).Conclusion. The clinicians should adhere to the polymerization time recommended by the manufacturer to ensure the durability of the composite material in the oral environment.

24 May 2018 in Journal of Adhesion Science and Technology
Verified
Journal Article
Closed access
NANeslihan Arhun
Neslihan Arhun
DBDerya Merve Halacoglu Bagis
Derya Merve Halacoglu Bagis
ZÖZümrüt Ceren Özduman
Zümrüt Ceren Özduman
DTDuygu Tuncer
Duygu Tuncer
Purpose: To evaluate the wetting ability and the microtensile bond strength of adhesive systems in various depths of dentin. Materials and Method: 48 extracted human molars cut in half in buccolingual direction. Buccal and lingual surfaces were used to obtain deep (n = 48) and superficial (n = 48) dentin. Groups were divided into 4 subgroups: Self-etch (CSE), etch&rinse (SB), multi-mode self-etch (SAU) and multimode etch&rinse (EAU) adhesive systems. 3 consecutive contact-angle measurements were obtained: T0- 3 μl drop of distilled water on dentin; T1-Droplet of the adhesive; T2- Distilled water after polymerization of the adhesive. After composite build-ups, microtensile measurements were performed. Contact angle data were analysed with analysis of variance for repeated measures. Bond strength data were analyzed by repeated measures analysis of variance, comparisons were made according to the logarithmic values (p < 0.05). Results: The difference between groups was not significant regardless of dentin depth for all measurements (p < 0.05). All groups except CSE enhanced the wetting ability of the adhesive but reduced the wetting ability of distilled water after application of the adhesive (p < 0.05). Regarding adhesive systems, the groups showed no significant difference between bond strengths to various depths of dentin except SAU (p > 0.05); in SAU, bond strength to deep dentine were significantly higher than superficial dentin (p < 0.05). Regarding adhesives’ bond strength, CSE showed significantly greater values than the other groups (p < 0.05). Conclusion: The cavity depth does not affect the bonding ability for all adhesive systems; self-etch adhesive systems might be a better choice since different adhesives may influence the wetting ability and microtensile bond strength of the dentin substrates.

16 December 2022 in Bezmialem Science
Verified
Journal Article
Closed access
LFLeyla Fazlioğlu
Leyla Fazlioğlu
BOBurcu oglakci ozkoc
Burcu oglakci ozkoc
ZÖZümrüt Ceren Özduman
Zümrüt Ceren Özduman
EDEvrim Eli̇gÜzeloğlu Dalkiliç
Evrim Eli̇gÜzeloğlu Dalkiliç

20 July 2020 in Journal of Adhesion Science and Technology
Verified
Journal Article
Closed access
BOBurcu oglakci ozkoc
Burcu oglakci ozkoc
DBDerya Merve Halacoglu Bagis
Derya Merve Halacoglu Bagis
ZÖZümrüt Ceren Özduman
Zümrüt Ceren Özduman
EDEvrim Eliguzeloglu Dalkilic
Evrim Eliguzeloglu Dalkilic
This in vitro study evaluated the volumetric change (VC) and gap formation (GF) in Class V composite restorations after light-curing and aging. Thirty-six extracted human premolars were used. Standardized Class V cavities (3 mmx3 mmx1.5 mm) were prepared. G-Premio Bond was applied. The teeth were randomly assigned into six groups (n = 6): Group FZ: Filtek Z250(microhybrid), Group SP: SDR Plus Bulk Fill Flowable (low-viscosity bulk-fill), Group EB: Estelite Bulk Fill Flow (low-viscosity bulk-fill), Group GI: G-aenial Universal Injectable (highly-filled low-viscosity), Group AF: Admira Fusion (ormocer), Group SX: Solare X (nanohybrid). Each specimen was scanned four times with micro-CT (SkyScan 1174v2, Belgium): after cavity preparation, before and after light-curing, and after aging. The VC (%) and GF (mm3) parameters were quantified and analysed. Then, VC after light-curing was verified with AcuVol video image analyser (n = 6). The specimens were submitted to 10,000 thermocycles (5–55 °C) and 100,000 load cycles (50N). The data were statistically analysed using the Kruskal-Wallis, Wilcoxon and Dunn tests (p < 0.05). After light-curing, Group AF and FZ showed significantly lower VC than Group GI. Group GI showed significantly higher total GF than Group AF, EB, FZ and SX. Group GI showed significantly higher GF than Group AF, EB and FZ in cervical region. After aging, a significant increase in the volume of the gap (VG) in cervical region was found for Group FZ and GI (p < 0.05). After light-curing, ormocer and microhybrid composites exhibited lower VC and GF than highly-filled low-viscosity composites. After aging, an increase in VG was observed for microhybrid and highly-filled low-viscosity composites for cervical region.

24 August 2023 in Coatings
Verified
Journal Article
Open access
PDF file
SYSevda Ozturk Yesilirmak
Sevda Ozturk Yesilirmak
BOBurcu oglakci ozkoc
Burcu oglakci ozkoc
ZÖZümrüt Ceren Özduman
Zümrüt Ceren Özduman
EDEvrim Eliguzeloglu Dalkilic
Evrim Eliguzeloglu Dalkilic
This study aimed to investigate the effects of different powers of Er:YAG laser irradiation on the shear bond strength (SBS) of repaired CAD/CAM resin-based composite materials. A total of 180 CAD/CAM resin-based composite specimens (5 × 5 × 2 mm) were obtained (Shofu Block HC—SB; Grandio Blocs—GB). They were allocated into six groups according to surface pretreatment methods: no surface pretreatment (control), hydrofluoric acid (HF), diamond bur and 3 W, 5 W, and 7 W Er:YAG lasers (20 Hz) (n = 15). Silane and universal adhesive were applied. The repair procedure was completed with nano-ceramic composite resin (Ceram-X Sphere TEC-One). The samples were thermocycled for 10,000 cycles (5–55 °C). The SBS was evaluated with a universal test machine (1 mm/min). A 3D optic profilometer was used to assess the surface topography. Statistical analysis was performed with a two-way ANOVA and Bonferroni tests (p < 0.05). For SB samples, HF and diamond bur caused significantly higher SBSs than 3 W and 7 W lasers, while for GB samples, they led to a significantly higher SBS than all laser treatments. For SB samples, the 5 W laser led to the highest SBS, while for GB samples, the 7 W laser caused the highest SBS (p < 0.05). For both blocks, adhesive failure was more common for the 3 W laser, and a decrease in adhesive failures and an increase in mixed failures were observed with increasing laser irradiation. The 3D optic profilometer revealed that smoother surfaces were obtained with the 3 W laser than other laser irradiation at different powers. Pretreatment with increasing Er:YAG laser powers led to similar bond strengths to hydrofluoric-acid- and diamond-bur-treated CAD/CAM resin-based composite materials. A more powerful laser treatment is required to provide a higher bond strength for restorative materials containing a higher inorganic ceramic content.