Nivine Attoue

Mrs. Nivine Attoue

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 February 2018 in Energies
Verified
Journal Article
Open access
PDF file
NANivine Attoue
Nivine Attoue
Isam ShahrourIsam Shahrour
Isam Shahrour
RYRafic Younes
Rafic Younes
The smart building concept aims to use smart technology to reduce energy consumption, as well as to improve comfort conditions and users’ satisfaction. It is based on the use of smart sensors and software to follow both outdoor and indoor conditions for the control of comfort, and security devices for the optimization of energy consumption. This paper presents a data-based model for indoor temperature forecasting, which could be used for the optimization of energy device use. The model is based on an artificial neural network (ANN), which is validated on data recorded in an old building. The novelty of this work consists of the methodology proposed for the development of a simplified model for indoor temperature forecasting. This methodology is based on the selection of pertinent input parameters after a relevance analysis of a large set of input parameters, including solar radiation outdoor temperature history, outdoor humidity, indoor facade temperature, and humidity. It shows that an ANN-based model using outdoor and facade temperature sensors provides good forecasting of indoor temperatures. This model can be easily used in the optimal regulation of buildings’ energy devices.

1 October 2021 in Smart Cities
Verified
Journal Article
Open access
PDF file
NMNeda Mashhadi
Neda Mashhadi
Isam ShahrourIsam Shahrour
Isam Shahrour
NANivine Attoue
Nivine Attoue
EJEL KHATTABI JAMAL
EL KHATTABI JAMAL
AAAmmar Aljer
Ammar Aljer
This paper presents an investigation of the capacity of machine learning methods (ML) to localize leakage in water distribution systems (WDS). This issue is critical because water leakage causes economic losses, damages to the surrounding infrastructures, and soil contamination. Progress in real-time monitoring of WDS and ML has created new opportunities to develop data-based methods for water leak localization. However, the managers of WDS need recommendations for the selection of the appropriate ML methods as well their practical use for leakage localization. This paper contributes to this issue through an investigation of the capacity of ML methods to localize leakage in WDS. The campus of Lille University was used as support for this research. The paper is presented as follows: First, flow and pressure data were determined using EPANET software; then, the generated data were used to investigate the capacity of six ML methods to localize water leakage. Finally, the results of the investigations were used for leakage localization from offline water flow data. The results showed excellent performance for leakage localization by the artificial neural network, logistic regression, and random forest, but there were low performances for the unsupervised methods because of overlapping clusters.

29 August 2019 in Buildings
Verified
Journal Article
Open access
PDF file
NANivine Attoue
Nivine Attoue
Isam ShahrourIsam Shahrour
Isam Shahrour
HMH. Mroueh
H. Mroueh
RYRafic Younes
Rafic Younes
The use of grey-box models for short-time forecasting of buildings’ thermal behavior requires the determination of the models’ order since this order could influence the grey-box models’ performance. This paper presents an analysis of the optimal order of these models for different thermal conditions. The novelty of this work consists of considering the influence of the heating conditions on the determination of the performances of grey-box models. The analysis is based on experimental tests that were conducted in a room with different thermal conditions, related to the variation of the heating power. Experimental results were used for the determination of the optimal grey-box models’ order that minimizes the gap between the experimental results and the grey-box forecasting. Results show that the optimal grey-box models’ order depends on the buildings’ thermal conditions, but generally lies between two and three with an error less than 0.2 °C and a fit percent greater than 90%.