CR-39 nuclear track material is frequently used for the detection of protons accelerated in laser-plasma interactions. The measurement of track densities allows for determination of particle angular distributions, and information on the kinetic energy can be obtained by the use of passive absorbers. We present a precise method of measuring spectral distributions of laser-accelerated protons in a single etching and analysis process. We make use of a one-to-one relation between proton energy and track size and present a precise calibration based on monoenergetic particle beams. While this relation is limited to proton energies below 1 MeV, we show that the range of spectral measurements can be significantly extended by simultaneous use of absorbers of suitable thicknesses. Examples from laser-plasma interactions are presented, and quantitative results on proton energies and particle numbers are compared to those obtained from a time-of-flight detector. The spectrum end points of continuous energy distributions have been determined with both detector types and coincide within 50-100 keV.
1 December 2015 in IEEE Transactions on Nuclear Science
We present the calibration and performance tests carried out with two detectors for intense proton pulses accelerated by lasers. Most of the procedures were realized with proton beams of 0.46-5.60 MeV from a tandem accelerator. One approach made use of radiochromic films, for which we calibrated the relation between optical density and energy deposition over more than three orders of magnitude. The validity of these results and of our analysis algorithms has been confirmed by controlled irradiation of film stacks and reconstruction of the total beam charge for strongly non-uniform beam profiles. For the spectral analysis of protons from repeated laser shots, we have designed an online monitor based on a plastic scintillator. The resulting signal from a photomultiplier directly measured on a fast oscilloscope is especially useful for time-of-flight applications. Variable optical filters allow for suppression of saturation and an extension of the dynamic range. With pulsed proton beams we have tested the detector response to a wide range of beam intensities from single particles to 3 ×10 5 protons per 100 ns time interval.
12 March 2024 in High Power Laser Science and Engineering
A multi-shot target assembly and automatic alignment procedure for laser–plasma proton acceleration at high repetition rate are introduced. The assembly is based on a multi-target rotating wheel capable of hosting more than 5000 targets, mounted on a 3D motorized stage to allow rapid replenishment and alignment of the target material between laser irradiations. The automatic alignment procedure consists of a detailed mapping of the impact positions at the target surface prior to the irradiation that ensures stable operation of the target, which alongside the purpose-built design of the target wheel, enables operation at rates up to 10 Hz. Stable and continuous laser-driven proton acceleration at 10 Hz is demonstrated, with observed cut-off energy stability about 15%.
Laser-plasma interactions at high intensities are often accompanied by emission of a strong electromagnetic pulse (EMP) interfering with particle detectors or other electronic equipment. We present experimental evidence for significant differences in noise amplitudes in laser-proton acceleration from aluminium as compared to mylar target foils. Such dissimilarities have been consistently observed throughout two series of measurements indicating that, under otherwise identical conditions, the target conductivity is the principal parameter related to EMP generation. In addition, the lateral size of the target foils correlates with the absolute noise levels. A frequency analysis combined with numerical simulations allows for an identification of several sources of radiofrequency emission in the MHz-GHz regime. Further, the temporal evolution of single frequencies on the nanosecond scale provides information on distinct excitation mechanisms.
29 September 2015 in IEEE Transactions on Nuclear Science
In γ-ray detectors, monolithic scintillation crystals offer the possibility of preserving the scintillation light distribution especially when painted black. The statistical moments of this distribution provide accurate information on the three photon impact coordinates, including their depth of interaction (DOI). Digital SiPMs (dSiPMs) return digital information based on pixels about the collected light distribution, since the signal is a digital sum of the trigger bins. In this work we present, for the first time, an accurate analysis of the statistical moments of the light distribution using monolithic painted black crystals and state-of-the-art dSiPMs. Two 32.6 ×32.6 mm 2 monolithic LYSO crystals covering the entire photodetectors area have been used in coincidence with 10 mm in thickness. The photosensor tiles were kept at a stable temperature of T = 20 ° C. Energy resolution of about 18% was reached in relation to the zeroth moment. The first moment, related to the impact position, determined a spatial resolution of about 3 mm near the crystal center, but quadratically degrading towards the crystal borders. The DOI resolution, measured by means of the second moment, was found to be nearing 4 mm in the crystal center region. The third order moment, the so-called skewness, is related to the degree of truncation and once calibrated minimizes the compression effects. A corrected spatial resolution of about 3 mm was then measured for the entire crystal surface. DOI resolution improved at the crystal's center, reaching 3.5 mm, but a degradation towards the borders remained due to truncation of the scintillation light distribution.