Andreas Pettersson

Dr. Andreas Pettersson


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2024 in Medicina
Verified
Journal Article
Open access
PDF file
HNHassan Mashad Nemati
Hassan Mashad Nemati
ACAlbin Christensson
Albin Christensson
APAndreas Pettersson
Andreas Pettersson
GNGunnar Németh
Gunnar Németh
GFGunnar Flivik
Gunnar Flivik
Background and Objectives: Navigation systems are designed to enhance surgical precision, improving patient outcomes and reducing the risk of implant misplacement. In this study, we have evaluated a novel orthopedic surgical platform that utilizes CT imaging with AI-based algorithms to automate several critical aspects of total hip arthroplasty. It contains three modules—preoperative planning, navigation during surgery, and follow-up analysis. The primary objective of the current study was to evaluate the precision of the navigation tool in cup placement, i.e., whether the information displayed for navigation correctly reflected the actual position of the implant. Materials and Methods: Surgery outcomes of 15 inter-rater measurements on human cadavers and 18 surgeries on patients who underwent total hip replacement using the navigation tool were analyzed. Results: In the inter-rater assessment, the mean errors were −0.31 ± 1.42° for anteversion, 1.06 ± 1.73° for inclination, and −0.94 ± 1.76 mm for cup position depth. In patients’ surgeries, the mean errors were −0.07 ± 2.72° for anteversion, −0.2 ± 0.86° for inclination, and 0.28 ± 0.78 mm for cup depth. Conclusions: The navigation tool offers intra-operative guidance on notable precision in cup placement, thereby effectively mitigating the risk of cup malpositioning outside the patient-specific safe zone.

14 May 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
HNHassan Mashad Nemati
Hassan Mashad Nemati
ACAlbin Christensson
Albin Christensson
APAndreas Pettersson
Andreas Pettersson
GFGunnar Flivik
Gunnar Flivik
Background/Objectives: Radiostereometric analysis (RSA) is the gold standard for measuring implant migration, with CT-RSA increasingly used as an alternative. To evaluate CT-RSA, it is important to assess data that include the surrounding soft tissues, rather than data from simplified phantoms, while also avoiding unnecessary radiation from multiple scans. This study proposes a method for generating multiple follow-up CTs from a single post-operative CT (baseline CT) by simulating stem migration and uses it to assess an AI-based CT-RSA tool. Methods: The method involves extracting the stem implant voxels from the baseline CT, digitally translating them along the x-, y-, and z-axes, and storing the result as new follow-up CTs. The voxel spacing of the baseline CT is used to define the ground-truth translations, which are then compared with the AI-based CT-RSA results using descriptive statistics and Bland–Altman plots. Results: Using 10 patients’ baseline CTs, 780 follow-up CTs were generated. Bland–Altman analysis showed a mean difference of 0.00 mm, largest LoA −0.10 to 0.09 mm, and translational precision for zero-migration of 0.026 to 0.049 mm. Conclusions: The proposed method offers a practical alternative to phantom-based models, and the AI-based CT-RSA showed high accuracy and precision for stem translation. The study addresses translational migration only.