Hassan Mashad Nemati

Dr. Hassan Mashad Nemati

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2024 in Medicina
Verified
Journal Article
Open access
PDF file
HNHassan Mashad Nemati
Hassan Mashad Nemati
ACAlbin Christensson
Albin Christensson
APAndreas Pettersson
Andreas Pettersson
GNGunnar Németh
Gunnar Németh
GFGunnar Flivik
Gunnar Flivik
Background and Objectives: Navigation systems are designed to enhance surgical precision, improving patient outcomes and reducing the risk of implant misplacement. In this study, we have evaluated a novel orthopedic surgical platform that utilizes CT imaging with AI-based algorithms to automate several critical aspects of total hip arthroplasty. It contains three modules—preoperative planning, navigation during surgery, and follow-up analysis. The primary objective of the current study was to evaluate the precision of the navigation tool in cup placement, i.e., whether the information displayed for navigation correctly reflected the actual position of the implant. Materials and Methods: Surgery outcomes of 15 inter-rater measurements on human cadavers and 18 surgeries on patients who underwent total hip replacement using the navigation tool were analyzed. Results: In the inter-rater assessment, the mean errors were −0.31 ± 1.42° for anteversion, 1.06 ± 1.73° for inclination, and −0.94 ± 1.76 mm for cup position depth. In patients’ surgeries, the mean errors were −0.07 ± 2.72° for anteversion, −0.2 ± 0.86° for inclination, and 0.28 ± 0.78 mm for cup depth. Conclusions: The navigation tool offers intra-operative guidance on notable precision in cup placement, thereby effectively mitigating the risk of cup malpositioning outside the patient-specific safe zone.

29 January 2024 in Acta Orthopaedica
Verified
Journal Article
Open access
PDF file
ACAlbin Christensson
Albin Christensson
HNHassan Mashad Nemati
Hassan Mashad Nemati
GFGunnar Flivik
Gunnar Flivik
Background and purpose: Radiostereometry (RSA) is the current gold standard for evaluating early implant migration. CT-based migration analysis is a promising method, with fewer handling requirements compared with RSA and no need for implanted bone-markers. We aimed to evaluate agreement between a new artificial intelligence (AI)-based CT-RSA and model-based RSA (MBRSA) in measuring migration of cup and stem in total hip arthroplasty (THA).Patients and methods: 30 patients with THA for primary osteoarthritis (OA) were included. RSA examinations were performed on the first postoperative day, and at 2 weeks, 3 months, 1, 2, and 5 years after surgery. A low-dose CT scan was done at 2 weeks and 5 years. The agreement between the migration results obtained from MBRSA and AI-based CT-RSA was assessed using Bland–Altman plots.Results: Stem migration (y-translation) between 2 weeks and 5 years, for the primary outcome measure, was –0.18 (95% confidence interval [CI] –0.31 to –0.05) mm with MBRSA and –0.36 (CI –0.53 to –0.19) mm with AI-based CT-RSA. Corresponding proximal migration of the cup (y-translation) was 0.06 (CI 0.02–0.09) mm and 0.02 (CI –0.01 to 0.05) mm, respectively. The mean difference for all stem and cup comparisons was within the range of MBRSA precision. The AI-based CT-RSA showed no intra- or interobserver variability.Conclusion: We found good agreement between the AI-based CT-RSA and MBRSA in measuring postoperative implant migration. AI-based CT-RSA ensures user independence and delivers consistent results.

2 August 2018 in Energies
Verified
Journal Article
Open access
PDF file
HNHassan Mashad Nemati
Hassan Mashad Nemati
ALAlberto Laso
Alberto Laso
Mario MananaMario Manana
Mario Manana
ASAnita Sant'Anna
Anita Sant'Anna
Slawomir NowaczykSlawomir Nowaczyk
Slawomir Nowaczyk
The maximum current that an overhead transmission line can continuously carry depends on external weather conditions, most commonly obtained from real-time streaming weather sensors. The accuracy of the sensor data is very important in order to avoid problems such as overheating. Furthermore, faulty sensor readings may cause operators to limit or even stop the energy production from renewable sources in radial networks. This paper presents a method for detecting and replacing sequences of consecutive faulty data originating from streaming weather sensors. The method is based on a combination of (a) a set of constraints obtained from derivatives in consecutive data, and (b) association rules that are automatically generated from historical data. In smart grids, a large amount of historical data from different weather stations are available but rarely used. In this work, we show that mining and analyzing this historical data provides valuable information that can be used for detecting and replacing faulty sensor readings. We compare the result of the proposed method against the exponentially weighted moving average and vector autoregression models. Experiments on data sets with real and synthetic errors demonstrate the good performance of the proposed method for monitoring weather sensors.

11 December 2025 in Acta Orthopaedica
Verified
Journal Article
Open access
PDF file
ACAlbin Christensson
Albin Christensson
HNHassan Mashad Nemati
Hassan Mashad Nemati
KYKristina Ydström
Kristina Ydström
GFGunnar Flivik
Gunnar Flivik
Background and purpose: Computed tomography (CT) has become a valuable tool for preoperative planning and perioperative, real-time navigation during total hip arthroplasty (THA). CT can also quantify postoperative implant migration without the need for implanted bone markers, making it a promising alternative to the current gold standard radiostereometric analysis (RSA). Our aim was to evaluate the accuracy of preoperative planning and postoperative implant migration of both cup and stem employing AI-based software using 3D CT-images (CT-RSA) compared with conventional RSA.Methods: 26 patients with primary THA were preoperatively 3D-planned and perioperatively navigated. They were followed and analyzed with AI-based CT-RSA within 2 days postoperatively and at 3, 12, and 24 months. 10 of the patients had implanted tantalum markers at surgery and were also followed up with conventional model-based RSA (MBRSA). The results were compared with CT-RSA. Prosthetic CAD models were used for both conventional RSA and AI-based CT-RSA analysis. Double CT and MBRSA scans were taken to evaluate precision. The preoperative plan was compared with actual perioperatively chosen implants.Results: AI-based CT-RSA showed consistent migration patterns, with most migration in the first 3 months, which then levelled out. Bland–Altman plots indicated good agreement between MBRSA and AI-based CT-RSA. Overall, there was high correspondence between MBRSA and AI-based CT-RSA in translations, but more divergent rotation results. AI-based CT-RSA precision was consistently slightly better than MBRSA precision. The agreement between planned and actual size of cup was 25 out of 26, and 23 out of 26 for stems.Conclusion: AI-based CT-RSA demonstrated accuracy comparable to MBRSA, with slightly improved precision and reduced user-dependence. The same system also provided an accurate and predictable preoperative implant plan.

27 February 2016
Verified
Book Chapter
Closed access
PDF file
HNHassan Mashad Nemati
Hassan Mashad Nemati
YFYuantao Fan
Yuantao Fan
FAFernando Alonso-Fernandez
Fernando Alonso-Fernandez

14 May 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
HNHassan Mashad Nemati
Hassan Mashad Nemati
ACAlbin Christensson
Albin Christensson
APAndreas Pettersson
Andreas Pettersson
GFGunnar Flivik
Gunnar Flivik
Background/Objectives: Radiostereometric analysis (RSA) is the gold standard for measuring implant migration, with CT-RSA increasingly used as an alternative. To evaluate CT-RSA, it is important to assess data that include the surrounding soft tissues, rather than data from simplified phantoms, while also avoiding unnecessary radiation from multiple scans. This study proposes a method for generating multiple follow-up CTs from a single post-operative CT (baseline CT) by simulating stem migration and uses it to assess an AI-based CT-RSA tool. Methods: The method involves extracting the stem implant voxels from the baseline CT, digitally translating them along the x-, y-, and z-axes, and storing the result as new follow-up CTs. The voxel spacing of the baseline CT is used to define the ground-truth translations, which are then compared with the AI-based CT-RSA results using descriptive statistics and Bland–Altman plots. Results: Using 10 patients’ baseline CTs, 780 follow-up CTs were generated. Bland–Altman analysis showed a mean difference of 0.00 mm, largest LoA −0.10 to 0.09 mm, and translational precision for zero-migration of 0.026 to 0.049 mm. Conclusions: The proposed method offers a practical alternative to phantom-based models, and the AI-based CT-RSA showed high accuracy and precision for stem translation. The study addresses translational migration only.