Arnold Chin Tse Ng

Arnold Chin Tse Ng

Auto-generated profile, based on publicly available information

Arnold Chin Tse Ng

Department of Cardiology, Princess Alexandra Hospital, Brisbane, Australia

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2010 in Circulation: Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
ANArnold C.T. Ng
Arnold C.T. Ng
VDVictoria Delgado
Victoria Delgado
FKFrank van der Kley
Frank van der Kley
MSMiriam Shanks
Miriam Shanks
NVNico R.L. van de Veire
Nico R.L. van de Veire
JBJeroen Bax
Jeroen Bax
Background— 3D transesophageal echocardiography (TEE) may provide more accurate aortic annular and left ventricular outflow tract (LVOT) dimensions and geometries compared with 2D TEE. We assessed agreements between 2D and 3D TEE measurements with multislice computed tomography (MSCT) and changes in annular/LVOT areas and geometries after transcatheter aortic valve implantations (TAVI).

1 November 2009 in The American Journal of Cardiology
Verified
Journal Article
Closed access
ANArnold C.T. Ng
Arnold C.T. Ng
VDVictoria Delgado
Victoria Delgado
Matteo BertiniMatteo Bertini
Matteo Bertini
RMRutger W. van der Meer
Rutger W. van der Meer
LRLuuk J. Rijzewijk
Luuk J. Rijzewijk
JBJeroen J. Bax
Jeroen J. Bax

1 January 2011 in Circulation
Verified
Journal Article
Closed access
VDVictoria Delgado
Victoria Delgado
RBRutger J. van Bommel
Rutger J. van Bommel
Matteo BertiniMatteo Bertini
Matteo Bertini
CBC. Jan Willem Borleffs
C. Jan Willem Borleffs
NMNina Ajmone Marsan
Nina Ajmone Marsan
JBJeroen J. Bax
Jeroen J. Bax
Background—: The relative merits of left ventricular (LV) dyssynchrony, LV lead position, and myocardial scar to predict long-term outcome after cardiac resynchronization therapy remain unknown and were evaluated in the present study. Methods and Results—: In 397 ischemic heart failure patients, 2-dimensional speckle tracking imaging was performed, with comprehensive assessment of LV radial dyssynchrony, identification of the segment with latest mechanical activation, and detection of myocardial scar in the segment where the LV lead was positioned. For LV dyssynchrony, a cutoff value of 130 milliseconds was used. Segments with 50% transmurality, validated in a subgroup with contrast-enhanced magnetic resonance imaging). The LV lead position was derived from chest x-ray. Long-term follow-up included all-cause mortality and hospitalizations for heart failure. Mean baseline LV radial dyssynchrony was 133±98 milliseconds. In 271 patients (68%), the LV lead was placed at the latest activated segment (concordant LV lead position), and the mean value of peak radial strain at the targeted segment was 18.9±12.6%. Larger LV radial dyssynchrony at baseline was an independent predictor of superior long-term survival (hazard ratio, 0.995; P =0.001), whereas a discordant LV lead position (hazard ratio, 2.086; P =0.001) and myocardial scar in the segment targeted by the LV lead (hazard ratio, 2.913; P <0.001) were independent predictors of worse outcome. Addition of these 3 parameters yielded incremental prognostic value over the combination of clinical parameters. Conclusions—: Baseline LV radial dyssynchrony, discordant LV lead position, and myocardial scar in the region of the LV pacing lead were independent determinants of long-term prognosis in ischemic heart failure patients treated with cardiac resynchronization therapy. Larger baseline LV dyssynchrony predicted superior long-term survival, whereas discordant LV lead position and myocardial scar predicted worse outcome.

1 December 2008 in American Heart Journal
Verified
Journal Article
Closed access
DLDominic Y. Leung
Dominic Y. Leung
ABAnita Boyd
Anita Boyd
ANArnold A. Ng
Arnold A. Ng
CCCecilia Chi
Cecilia Chi
LTLiza Thomas
Liza Thomas

1 November 2011 in The American Journal of Cardiology
Verified
Journal Article
Closed access
SESee Hooi Ewe
See Hooi Ewe
ANArnold C.T. Ng
Arnold C.T. Ng
JSJoanne D. Schuijf
Joanne D. Schuijf
FKFrank van der Kley
Frank van der Kley
ACAndrea Colli
Andrea Colli
VDVictoria Delgado
Victoria Delgado

19 February 2010 in European Heart Journal
Verified
Journal Article
Open access
PDF file
VDVictoria Delgado
Victoria Delgado
ANArnold C.T. Ng
Arnold C.T. Ng
NVNico R. van de Veire
Nico R. van de Veire
FKFrank van der Kley
Frank van der Kley
JSJoanne D. Schuijf
Joanne D. Schuijf
JBJeroen Bax
Jeroen Bax
Aortic regurgitation after transcatheter aortic valve implantation (TAVI) is one of the most frequent complications. However, the underlying mechanisms of this complication remain unclear. The present evaluation studied the anatomic and morphological features of the aortic valve annulus that may predict aortic regurgitation after TAVI. In 53 patients with severe aortic stenosis undergoing TAVI, multi-detector row computed tomography (MDCT) assessment of the aortic valve apparatus was performed. For aortic valve annulus sizing, two orthogonal diameters were measured (coronal and sagittal). In addition, the extent of valve calcifications was quantified. At 1-month follow-up after procedure, MDCT was repeated to evaluate and correlate the prosthesis deployment to the presence of aortic regurgitation. Successful procedure was achieved in 48 (91%) patients. At baseline, MDCT demonstrated an ellipsoid shape of the aortic valve annulus with significantly larger coronal diameter when compared with sagittal diameter (25.1 ± 2.4 vs. 22.9 ± 2.0 mm, P < 0.001). At follow-up, MDCT showed a non-circular deployment of the prosthesis in six (14%) patients. Moderate post-procedural aortic regurgitation was observed in five (11%) patients. These patients showed significantly larger aortic valve annulus (27.3 ± 1.6 vs. 24.8 ± 2.4 mm, P = 0.007) and more calcified native valves (4174 ± 1604 vs. 2444 ± 1237 HU, P = 0.005) at baseline and less favourable deployment of the prosthesis after TAVI. Multi-detector row computed tomography enables an accurate sizing of the aortic valve annulus and constitutes a valuable imaging tool to evaluate prosthesis location and deployment after TAVI. In addition, MDCT helps to understand the underlying mechanisms of post-procedural aortic regurgitation.