In high-power insulated gate bipolar transistor (IGBT) module thermal management, the structural design of microchannel cooling plates plays a crucial role in determining heat dissipation efficiency and temperature uniformity. This study focuses on the effects of honeycomb-structured unit dimensions and arrangements, as well as inlet/outlet configurations of the cooling plate on its thermal and flow performance. Additionally, the influence of different coolant inlet velocities and temperatures is investigated. Under constant coolant flow rate and boundary conditions, four design configurations with varying pore widths and channel spacings were evaluated numerically. The results indicate that the optimized honeycomb structure can reduce the module’s peak temperature by approximately 8.7 K while significantly improving temperature uniformity and maintaining a moderate pressure drop. Moreover, increasing the number of inlets and outlets effectively lowers the pressure drop and enhances thermal uniformity. Although increasing the coolant flow rate and reducing the inlet temperature can further improve cooling performance, these measures also lead to notable increases in energy consumption and pressure loss. Therefore, a trade-off between thermal enhancement and system energy efficiency must be considered in practical applications. The findings of this study provide practical guidance for the design optimization of high-efficiency microchannel liquid cooling systems in power electronic applications.

5 September 2024 in Energies
Verified
Journal Article
Open access
PDF file
JWJiadian Wang
Jiadian Wang
DLDongyang Lv
Dongyang Lv
HSHaonan Sha
Haonan Sha
CLChenguang Lai
Chenguang Lai
JZJun xiong Zeng
Jun xiong Zeng
YJYanjun Jiang
Yanjun Jiang
The thermal performance of a lithium-ion battery pack for an electric vehicle by adding straight rib turbulators in battery cooling plate channels has been numerically investigated in this paper and the numerical model of the battery pack has been validated by experimental data, which exhibits a satisfactory prediction accuracy. The effects of rib shapes, rib angles, rib spacings, and irregular gradient rib arrangement configurations on the flow and heat transfer behaviors of battery pack cooling plates have been thoroughly explored and analyzed in this paper. In addition, the thermal performance of the ribbed battery cooling plates was examined at actual high-speed climbing and low-temperature heating operating conditions. The results indicate that compared to the original smooth cooling plate, the square-ribbed battery cooling plate with a 60° angle and 5 mm spacing reduced the maximum battery temperature by 0.3 °C, but increased the cross-sectional temperature difference by 0.357 °C. To address this issue, a gradient rib arrangement was proposed, which slightly reduced the maximum battery temperature and lowered the cross-sectional temperature difference by 0.445 °C, significantly improving temperature uniformity. The thermal performance of the battery thermal management system with this gradient rib configuration meets the requirements for typical electric vehicle operating conditions, such as high-speed climbing and low-temperature heating conditions.

19 February 2025 in Energies
Verified
Journal Article
Open access
PDF file
TGTieyu Gao
Tieyu Gao
JWJiadian Wang
Jiadian Wang
HSHaonan Sha
Haonan Sha
浩阳浩 阳
浩 阳
CLChenguang Lai
Chenguang Lai
JZJun xiong Zeng
Jun xiong Zeng
This study numerically investigates the thermal performance of a refrigerant-based battery thermal management system (BTMS) under various operating conditions. A validated numerical model is used to examine the effects of cooling channel rib configurations (rib spacing and rib angles) and refrigerant parameters (mass flow rate and saturation temperature) on battery thermal behavior. Additionally, the impact of discharge C-rates is analyzed. The results show that a rib spacing of 11 mm and a rib angle of 60° reduce the maximum battery temperature by 0.8 °C (cooling rate of 2%) and improve temperature uniformity, though at the cost of a 130% increase in pressure drop. Increasing the refrigerant mass flow rate lowers the maximum temperature by up to 10%, but its effect on temperature uniformity diminishes beyond 20 kg/h. A lower saturation temperature enhances cooling but increases internal temperature gradients, while a higher saturation temperature improves uniformity at the expense of a slightly higher maximum temperature. Under high discharge rates (12C), the system’s cooling capacity becomes limited, leading to significant temperature rises. These findings provide insights that can aid in optimizing BTMS design to balance cooling performance, energy efficiency, and temperature uniformity.

13 August 2025 in Energies
Verified
Journal Article
Open access
PDF file
浩阳浩 阳
浩 阳
FWFan Wu
Fan Wu
JFJinhao Fu
Jinhao Fu
JZJun xiong Zeng
Jun xiong Zeng
XFXiaojin Fu
Xiaojin Fu
Feng ZhangFeng Zhang
Feng Zhang
This study investigates the thermal performance of an oil-jet-cooled permanent magnet synchronous motor (PMSM), with a particular focus on end-winding heat dissipation. A high-fidelity numerical model that preserves the full geometric complexity of the end-winding is developed and validated against experimental temperature data, achieving average deviations below 7%. To facilitate efficient parametric analysis, a simplified equivalent model is constructed by replacing the complex geometry with a thermally equivalent annular region characterized by calibrated radial conductivity. Based on this model, the effects of key spray ring parameters—including orifice diameter, number of nozzles, inlet oil temperature, and flow rate—are systematically evaluated. The results indicate that reducing the orifice diameter from 4 mm to 2 mm lowers the maximum winding temperature from 162 °C to 153 °C but increases the pressure drop from 205 Pa to 913 Pa. An optimal nozzle number of 12 decreases the peak winding temperature to 155 °C compared with 162 °C for 8 nozzles, while increasing the oil flow rate from 2 L/min to 6 L/min reduces the peak winding temperature from 162 °C to 142 °C. Furthermore, a non-uniform spray ring configuration decreases maximum stator, winding, spray ring, and shaft temperatures by 5.6–9.2% relative to the baseline, albeit with a pressure drop increase from 907 Pa to 1410 Pa. These findings provide quantitative guidance for optimizing oil-jet cooling designs for PMSMs under engineering constraints.

9 December 2025 in Energies
Verified
Journal Article
Open access
PDF file
YGYuhang Gao
Yuhang Gao
浩阳浩 阳
浩 阳
FWFan Wu
Fan Wu
JZJun xiong Zeng
Jun xiong Zeng
Feng ZhangFeng Zhang
Feng Zhang
This study undertakes a detailed computational examination of a direct refrigerant cooling approach for a 50 Ah prismatic lithium iron phosphate (LiFePO4) battery. We conducted a systematic assessment to determine how the cooling plate’s topological layout and flow orientation influenced key performance indicators, namely thermal homogeneity, heat removal efficiency, and hydraulic pressure loss. Utilizing a validated two-phase flow model with 1,1,1,2-Tetrafluoroethane (R134a), simulations were performed on six distinct serpentine channel designs under a wide range of operating scenarios, covering variations in mass flow rate, saturation temperature, and inlet vapor quality. The simulation data revealed a strong correlation between the cooling plate’s geometric parameters and the system’s thermal behavior. In terms of uniformity, the optimized Case 6 configuration significantly outperformed Case 2, achieving a 76% improvement by narrowing the maximum mid-plane temperature difference from 2.02 °C down to 0.48 °C. A trade-off was observed regarding the mass flow rate: while higher rates lowered the peak temperature by approximately 18%, they simultaneously led to increased hydraulic pressure loss and slight non-uniformity. Similarly, decreasing the saturation temperature improved heat extraction but exacerbated flow resistance. Notably, this study identified an inlet vapor quality of 0.1 as the optimal point for maximizing temperature uniformity. These insights provide a robust theoretical foundation for optimizing the design and operation of compact direct refrigerant-based BTMSs.

1 August 2025 in Physics of Fluids
Verified
Journal Article
Closed access
XFXiaojin Fu
Xiaojin Fu
JZJunxiong Zeng
Junxiong Zeng
浩阳浩 阳
浩 阳
GZGuangtao Zhai
Guangtao Zhai
CLChenguang Lai
Chenguang Lai
Thermocapillary actuation offers a simple and effective means to manipulate droplet motion, while surface modification provides a reliable method to control the thermocapillary migration of microdroplets with high accuracy and flexibility. In this study, the thermocapillary migration of droplets on single and dual-rail rectangular wettability-confined tracks under a uniform temperature gradient is investigated using a three-dimensional color-gradient thermal lattice Boltzmann model. The model's capability to simulate fluid–surface interactions is first validated through simulations of partial wetting behavior. Subsequently, droplet migration on a single track is examined and compared with that on a homogeneous hydrophilic surface. Particular attention is given to the influence of track width on droplet elongation and migration velocity, and non-monotonic dependencies are identified. Finally, droplet migration on dual-rail tracks is analyzed. A comprehensive investigation into the effects of track width, wettability, and the width of the interval region between the tracks is conducted, and the underlying mechanisms governing these effects are elucidated.