Xuan Liu

Dr. Xuan Liu


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2024 in Processes
Verified
Journal Article
Open access
PDF file
JBJie Bai
Jie Bai
CCChuan qiang Che
Chuan qiang Che
XLXuan Liu
Xuan Liu
LWLixin Wang
Lixin Wang
ZHZhiqiang He
Zhiqiang He
HZHongbo Zou
Hongbo Zou
Pumped storage units serve as a crucial support for power systems to adapt to large-scale and high-proportion renewable energy sources by providing a stable and flexible energy supply. However, due to the coupling effects of electric power load demands and the complex multi-source factors within the water–mechanical–electrical system, the interrelationship between unit parameters becomes more intricate, posing significant threats to the operational reliability and health status of the units. The complexity of fault diagnosis is further aggravated by the intricate and varied nature of fault characteristics, as well as the challenges in signal extraction under conditions of strong electromagnetic interference and high noise levels. To address these issues, this paper proposes a novel data-model hybrid-driven strategy that analyzes vibration signals to achieve rapid and accurate fault diagnosis of the units. Firstly, the spectral kurtosis theory is employed to enhance the traditional empirical mode decomposition, achieving optimal decomposition and noise reduction effects for vibration signals. Secondly, the intrinsic mode functions (IMFs) obtained from the decomposition are reconstructed, and the entropy values of effective IMFs are calculated as fault feature vectors. Subsequently, the CNN-LSTM model is utilized for fault diagnosis. The effectiveness and feasibility of the proposed method are verified through actual operational data from pumped storage units in a specific region. Through analysis, the fault diagnosis accuracy of the method proposed in this paper can be maintained above 95%, demonstrating robustness in complex engineering environments and effectively ensuring the safe and stable operation of pumped storage units.

30 September 2024 in Processes
Verified
Journal Article
Open access
PDF file
JBJie Bai
Jie Bai
XLXuan Liu
Xuan Liu
BDBingjie Dou
Bingjie Dou
XYXiaohui Yang
Xiaohui Yang
BCBo Chen
Bo Chen
HZHongbo Zou
Hongbo Zou
Stator faults are one of the common issues in pumped storage generators, significantly impacting their performance and safety. To ensure the safe and stable operation of pumped storage generators, a stator fault diagnosis method based on an improved short-time Fourier transform (STFT)-support vector data description (SVDD) hybrid algorithm is proposed. This method establishes a fault model for inter-turn short circuits in the stator windings of pumped storage generators and analyzes the electrical and magnetic states associated with such faults. Based on the three-phase current signals observed during an inter-turn short circuit fault in the stator windings, the three-phase currents are first converted into two-phase currents using the principle of equal magnetic potential. Then, the STFT is applied to transform the time-domain signals of the stator’s two-phase currents into frequency-domain signals, and the resulting fault current spectrum is input into the improved SVDD network for processing. This ultimately outputs the diagnosis result for inter-turn short circuit faults in the stator windings of the pumped storage generator. Experimental results demonstrate that this method can effectively distinguish between normal and faulty states in pumped storage generators, enabling the diagnosis of inter-turn short circuit faults in stator windings with low cross-entropy loss. Through analysis, under small data sample conditions, the accuracy of the proposed method in this paper can be improved by up to 7.2%. In the presence of strong noise interference, the fault diagnosis accuracy of the proposed method remains above 90%, and compared to conventional methods, the fault diagnosis accuracy can be improved by up to 6.9%. This demonstrates that the proposed method possesses excellent noise robustness and small sample learning ability, making it effective in complex, dynamic, and noisy environments.