Pumped storage units serve as a crucial support for power systems to adapt to large-scale and high-proportion renewable energy sources by providing a stable and flexible energy supply. However, due to the coupling effects of electric power load demands and the complex multi-source factors within the water–mechanical–electrical system, the interrelationship between unit parameters becomes more intricate, posing significant threats to the operational reliability and health status of the units. The complexity of fault diagnosis is further aggravated by the intricate and varied nature of fault characteristics, as well as the challenges in signal extraction under conditions of strong electromagnetic interference and high noise levels. To address these issues, this paper proposes a novel data-model hybrid-driven strategy that analyzes vibration signals to achieve rapid and accurate fault diagnosis of the units. Firstly, the spectral kurtosis theory is employed to enhance the traditional empirical mode decomposition, achieving optimal decomposition and noise reduction effects for vibration signals. Secondly, the intrinsic mode functions (IMFs) obtained from the decomposition are reconstructed, and the entropy values of effective IMFs are calculated as fault feature vectors. Subsequently, the CNN-LSTM model is utilized for fault diagnosis. The effectiveness and feasibility of the proposed method are verified through actual operational data from pumped storage units in a specific region. Through analysis, the fault diagnosis accuracy of the method proposed in this paper can be maintained above 95%, demonstrating robustness in complex engineering environments and effectively ensuring the safe and stable operation of pumped storage units.
Stator faults are one of the common issues in pumped storage generators, significantly impacting their performance and safety. To ensure the safe and stable operation of pumped storage generators, a stator fault diagnosis method based on an improved short-time Fourier transform (STFT)-support vector data description (SVDD) hybrid algorithm is proposed. This method establishes a fault model for inter-turn short circuits in the stator windings of pumped storage generators and analyzes the electrical and magnetic states associated with such faults. Based on the three-phase current signals observed during an inter-turn short circuit fault in the stator windings, the three-phase currents are first converted into two-phase currents using the principle of equal magnetic potential. Then, the STFT is applied to transform the time-domain signals of the stator’s two-phase currents into frequency-domain signals, and the resulting fault current spectrum is input into the improved SVDD network for processing. This ultimately outputs the diagnosis result for inter-turn short circuit faults in the stator windings of the pumped storage generator. Experimental results demonstrate that this method can effectively distinguish between normal and faulty states in pumped storage generators, enabling the diagnosis of inter-turn short circuit faults in stator windings with low cross-entropy loss. Through analysis, under small data sample conditions, the accuracy of the proposed method in this paper can be improved by up to 7.2%. In the presence of strong noise interference, the fault diagnosis accuracy of the proposed method remains above 90%, and compared to conventional methods, the fault diagnosis accuracy can be improved by up to 6.9%. This demonstrates that the proposed method possesses excellent noise robustness and small sample learning ability, making it effective in complex, dynamic, and noisy environments.
Pumped storage hydropower (PSH) is a key regulating resource for renewable energy integration and power system stability. Due to frequent start-stop operations, deep peak-load regulation, and bidirectional operating conditions, stator winding insulation degradation, rotor inter-turn short circuits, and end-winding vibration have become the dominant failure modes of pumped storage units. Conventional monitoring systems are limited by single-source sensing, asynchronous data acquisition, high misdiagnosis rates, and maintenance decisions that rely heavily on expert experience, making traditional periodic maintenance increasingly inadequate. To address these challenges, this study proposes an intelligent diagnosis and decision support system based on multi-source data fusion and hybrid intelligent algorithms. An Intelligent Electronic Device (IED)-based condition monitoring platform is developed by integrating multiple sensing technologies. Complete Variational Mode Decomposition (CVMD) and Kernel Principal Component Analysis (KPCA) are employed to extract representative features from multi-physical-field data, while an attention-enhanced Long Short-Term Memory (LSTM) network is introduced for accurate fault identification. In addition, adaptive time-alignment and joint denoising algorithms are developed to improve data quality and diagnostic robustness. A predictive maintenance framework incorporating health assessment and remaining useful life prediction is further established to optimize maintenance scheduling. Results demonstrate that the proposed system achieves a fault prediction accuracy of over 90% and reduces annual maintenance costs by approximately 15–20%. The proposed framework provides an effective solution for intelligent operation and maintenance of modern pumped storage units.
The end-winding insulation structure of stator windings in pumped-storage generator units is complex, with pronounced electric field concentration under out-of-phase conditions, making them critical concerns in insulation design and condition-based maintenance. Although the finite element method (FEM) offers reliable accuracy, the strong nonlinearity of the anti-corona layer results in a computation time exceeding 104 seconds per single solution, rendering it impractical for parameter optimization and rapid on-site assessment. This paper proposes a fast prediction method for end-region potential distribution based on a deep neural network (DNN). Taking a 334 MW unit as the research object, a three-dimensional electroquasistatic finite element model with six stator coils is established and validated through power-frequency withstand voltage and ultraviolet imaging experiments. Training samples are generated via design of experiments (DoE), and a multilayer DNN surrogate model with a 7-dimensional input (comprising 3D spatial coordinates and four physical parameters) and a 1-dimensional output is constructed to directly reconstruct the spatial potential field at the end region. The results demonstrate that the surrogate model achieves a maximum relative error of less than 2% along the entire path compared with the high-fidelity FEM solutions, with a single prediction time of approximately 38 s—representing a speedup factor of approximately 272—while also exhibiting good generalization capability. This method provides a feasible technical approach for rapid reconstruction of end-region field distribution and optimization of insulation structures.