Research Focus & Metrics

Academic Career Length

42Years (1985-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2008 in Medical Physics
Verified
Journal Article
Closed access
JWJ. Wulff
J. Wulff
KZKlemens Zink
Klemens Zink
IKI. Kawrakow
I. Kawrakow

17 October 2012 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
RGR Grün
R Grün
TFThomas Friedrich
Thomas Friedrich
TET Elsässer
T Elsässer
MKM Krämer
M Krämer
KZKlemens Zink
Klemens Zink
MSMichael Scholz
Michael Scholz
Biological optimization for treatment planning in carbon ion therapy is currently based on the first version of the local effect model (LEM I). Further developments implemented in the latest version (LEM IV) allowed to predict more accurately the Relative Biological Effectiveness (RBE) in-vitro. The main goal of this study is to compare the LEM IV against LEM I under treatment-like conditions for idealized target geometries. Therefore, physical dose distributions resulting from the biological optimization with LEM I were used to recalculate the RBE-weighted dose distribution based on LEM IV. Input parameters representing the clinical endpoints late toxicity in the central nervous system and the tumor control for chordoma were chosen to investigate the impact of changes on the predicted isoeffective dose levels. The recalculated RBE-weighted dose distributions show an increase within the target region, and the mean RBE-weighted dose values are dependent on the geometry and decrease with increasing target dimension. The differences between predictions of LEM IV and LEM I are less than 10% for typical tumor volumes treated in the pilot project at GSI. Median RBE-weighted doses predicted by LEM IV in the target region are consistent with clinically observed dose-response behavior as demonstrated by comparison to the 5-year local control curve for skull base chordoma.

6 May 2008 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
JWJ Wulff
J Wulff
JHJ T Heverhagen
J T Heverhagen
KZKlemens Zink
Klemens Zink
This paper presents a detailed investigation into the calculation of perturbation and beam quality correction factors for ionization chambers in high-energy photon beams with the use of Monte Carlo simulations. For a model of the NE2571 Farmer-type chamber, all separate perturbation factors as found in the current dosimetry protocols were calculated in a fixed order and compared to the currently available data. Furthermore, the NE2571 Farmer-type and a model of the PTW31010 thimble chamber were used to calculate the beam quality correction factor kQ. The calculations of kQ showed good agreement with the published values in the current dosimetry protocols AAPM TG-51 and IAEA TRS-398 and a large set of published measurements. Still, some of the single calculated perturbation factors deviate from the commonly used ones; especially prepl deviates more than 0.5%. The influence of various sources of uncertainties in the simulations is investigated for the NE2571 model. The influence of constructive details of the chamber stem shows a negligible dependence on calculated values. A comparison between a full linear accelerator source and a simple collimated point source with linear accelerator photon spectra yields comparable results. As expected, the calculation of the overall beam quality correction factor is sensitive to the mean ionization energy of graphite used. The measurement setup (source-surface distance versus source-axis distance) had no influence on the calculated values.

21 March 2013 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
DCD Czarnecki
D Czarnecki
KZKlemens Zink
Klemens Zink
The application of small photon fields in modern radiotherapy requires the determination of total scatter factors Scp or field factors Ω(f(clin), f(msr))(Q(clin), Q(msr)) with high precision. Both quantities require the knowledge of the field-size-dependent and detector-dependent correction factor k(f(clin), f(msr))(Q(clin), Q(msr)). The aim of this study is the determination of the correction factor k(f(clin), f(msr))(Q(clin), Q(msr)) for different types of detectors in a clinical 6 MV photon beam of a Siemens KD linear accelerator. The EGSnrc Monte Carlo code was used to calculate the dose to water and the dose to different detectors to determine the field factor as well as the mentioned correction factor for different small square field sizes. Besides this, the mean water to air stopping power ratio as well as the ratio of the mean energy absorption coefficients for the relevant materials was calculated for different small field sizes. As the beam source, a Monte Carlo based model of a Siemens KD linear accelerator was used. The results show that in the case of ionization chambers the detector volume has the largest impact on the correction factor k(f(clin), f(msr))(Q(clin), Q(msr)); this perturbation may contribute up to 50% to the correction factor. Field-dependent changes in stopping-power ratios are negligible. The magnitude of k(f(clin), f(msr))(Q(clin), Q(msr)) is of the order of 1.2 at a field size of 1 × 1 cm(2) for the large volume ion chamber PTW31010 and is still in the range of 1.05-1.07 for the PinPoint chambers PTW31014 and PTW31016. For the diode detectors included in this study (PTW60016, PTW 60017), the correction factor deviates no more than 2% from unity in field sizes between 10 × 10 and 1 × 1 cm(2), but below this field size there is a steep decrease of k(f(clin), f(msr))(Q(clin), Q(msr)) below unity, i.e. a strong overestimation of dose. Besides the field size and detector dependence, the results reveal a clear dependence of the correction factor on the accelerator geometry for field sizes below 1 × 1 cm(2), i.e. on the beam spot size of the primary electrons hitting the target. This effect is especially pronounced for the ionization chambers. In conclusion, comparing all detectors, the unshielded diode PTW60017 is highly recommended for small field dosimetry, since its correction factor k(f(clin), f(msr))(Q(clin), Q(msr)) is closest to unity in small fields and mainly independent of the electron beam spot size.

11 August 2017 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
YSYuri Simeonov
Yuri Simeonov
UWUli Weber
Uli Weber
PPPetar Penchev
Petar Penchev
TRToke Printz Ringbæk
Toke Printz Ringbæk
CSChristoph Schuy
Christoph Schuy
KZKlemens Zink
Klemens Zink
The purpose of this work was to design and manufacture a 3D range-modulator for scanned particle therapy. The modulator is intended to create a highly conformal dose distribution with only one fixed energy, simultaneously reducing considerably the treatment time. As a proof of concept, a 3D range-modulator was developed for a spherical target volume with a diameter of 5 cm, placed at a depth of 25 cm in a water phantom. It consists of a large number of thin pins with a well-defined shape and different lengths to modulate the necessary shift of the Bragg peak. The 3D range-modulator was manufactured with a rapid prototyping technique. The FLUKA Monte Carlo package was used to simulate the modulating effect of the 3D range-modulator and the resulting dose distribution. For that purpose, a special user routine was implemented to handle its complex geometrical contour. Additionally, FLUKA was extended with the capability of intensity modulated scanning. To validate the simulation results, dose measurements were carried out at the Heidelberg Ion Beam Therapy Center with a 400.41 MeV/u 12 C beam. The high resolution dosimetric measurements show a good agreement between simulated and measured dose distributions. Irradiation of the monoenergetic raster plan took 3 s, which is approximately 20 times shorter than a comparable plan with 16 different energies. The combination of only one energy and a 3D range-modulator leads to a tremendous decrease in irradiation time. ‘Interplay effects’, typical for moving targets and pencil beam scanning, can be immensely reduced or disappear completely, making the delivery of a homogeneous dose to moving targets more reliable. Combining high dose conformity, very good homogeneity and extremely short irradiation times, the 3D range-modulator is considered to become a clinically applicable method for very fast treatment of lung tumours.

29 January 2015 in Medical Physics
Verified
Journal Article
Closed access
PDF file
RGRebecca Grün
Rebecca Grün
TFThomas Friedrich
Thomas Friedrich
MKMichael Krämer
Michael Krämer
KZKlemens Zink
Klemens Zink
Marco DuranteMarco Durante
Marco Durante
MSMichael Scholz
Michael Scholz