A sensitive temperature sensor was demonstrated using boron-doped polarization-maintaining photonic crystal fiber (PM-PCF) as a Sagnac interferometer (SI). This boron-doped PM-PCF combines both the geometric birefringence introduced by the PCF structure design and the stress birefringence introduced by the boron-doped stress-applying parts. However, we found that the stress birefringence dominates the total birefringence of the sensor by numerical analysis. In the experiments, the fabricated sensor exhibited the highest temperature sensitivity of −1.83 nm/°C within the wide temperature range of 28~76 °C. The temperature sensitivity was mainly derived from the stress birefringence of boron-doped PM-PCF SI. These findings provide some support for the designation of high-precision temperature sensors.
In this study, a filtering scheme suitable for high-precision sensors was proposed to extract high-precision sensor information. According to the principle of Kalman gain based on data fusion, a model-less prediction filter with minimum gain measurement noise compensation and process noise posteriori constraint adjustment was developed. In comparison to various Kalman filter methods, the proposed algorithm demonstrated better accuracy in the steady state. The high precision performance and effectiveness of the model-less prediction filter were verified under a digitally controlled linear power supply.
Electrochemical conversion of chloride to active chlorine is promising for treating chloride-rich organic wastewater, but enhanced oxidant production does not necessarily improve electrical efficiency. Here, Ti–Sn–Sb@γ-Al2O3 particle electrodes were prepared and applied in a flow-through three-dimensional electrocatalytic oxidation (3DEO) system. Modification promoted chlorine evolution while suppressing oxygen evolution. Active chlorine production showed diminishing gains above 30 mA/cm2 and 10 g/L Cl−, whereas increasing flow rate improved production and reduced specific energy consumption. An 80% particle filling ratio provided the highest average generation rate. Initial pH (3–11) had limited influence because the solution became alkaline during electrolysis. For simulated aniline wastewater, 3DEO with NaCl achieved 95.20% aniline and ~47% total organic carbon (TOC) removal, compared with 77.33% aniline removal in the two-dimensional system. Specific energy consumption was ~110 Wh/g TOC, versus 1070 Wh/g with Na2SO4, while TOC-based current efficiency increased from ~11% to ~75%. The laboratory results demonstrate aniline and partial TOC removal. Chlorinated organic by-products and chlorate were not quantified, so effluent safety and practical applicability remain unverified.