A intensity-modulated optical fiber relative humidity (RH) sensor based on the side coupling induction technology (SCIT) is presented and experimentally demonstrated. The agarose gel and the twisted macro-bend coupling structure are first combined for RH sensing applications. The refractive index (RI) of the agarose gel increases with the increase of the RH and is in linear proportion from 20 to 80%RH. The side coupling power, which changes directly with the RI of the agarose gel, can strip the source noise from the sensor signal and improve the signal to noise ratio substantially. The experiment results show that the sensitivity of the proposed sensor increases while the bend radius decreases. When the bend radius is 8 mm, the sensor has a linear response from 40% to 80% RH with the sensitivity of 4.23 nW/% and the limit of detection of 0.70%. A higher sensitivity of 12.49 nW/% is achieved when RH raises from 80% to 90% and the limit of detection decreases to 0.55%. Furthermore, the proposed sensor is a low-cost solution, offering advantages of good reversibility, fast response time, and compensable temperature dependence.
This paper proposes the strategy of fabricating an all fiber wide-range displacement sensor based on the macro-bend coupling effect which causes power transmission between two twisted bending plastic optical fibers (POF), where the coupling power changes with the bending radius of the fibers. For the sensor, a structure of two twisted plastic fibers is designed with the experimental platform that we constructed. The influence of external temperature and displacement speed shifts are reported. The displacement sensor performance is the sensor test at different temperatures and speeds. The sensor was found to be satisfactory at both room temperature and 70 °C when the displacement is up to 140 mm. The output power is approximately linear to a displacement of 110 mm–140 mm under room temperature and 2 mm/s speed at 19.805 nW/mm sensitivity and 0.12 mm resolution. The simple structure of the sensor makes it reliable for other applications and further utilizations, promising a bright future.
A wireless passive pressure measurement system for an 800 °C high-temperature environment is proposed and the impedance variation caused by the mutual coupling between a read antenna and a LC resonant sensor is analyzed. The system consists of a ceramic-based LC resonant sensor, a readout device for impedance phase interrogation, heat insulating material, and a composite temperature-pressure test platform. Performances of the pressure sensor are measured by the measurement system sufficiently, including pressure sensitivity at room temperature, zero drift from room temperature to 800 °C, and the pressure sensitivity under the 800 °C high temperature environment. The results show that the linearity of sensor is 0.93%, the repeatability is 6.6%, the hysteretic error is 1.67%, and the sensor sensitivity is 374 KHz/bar. The proposed measurement system, with high engineering value, demonstrates good pressure sensing performance in a high temperature environment.
Wearable surface electromyography (sEMG) signal-acquisition devices have considerable potential for medical applications. Signals obtained from sEMG armbands can be used to identify a person’s intentions using machine learning. However, the performance and recognition capabilities of commercially available sEMG armbands are generally limited. This paper presents the design of a wireless high-performance sEMG armband (hereinafter referred to as the α Armband), which has 16 channels and a 16-bit analog-to-digital converter and can reach 2000 samples per second per channel (adjustable) with a bandwidth of 0.1–20 kHz (adjustable). The α Armband can configure parameters and interact with sEMG data through low-power Bluetooth. We collected sEMG data from the forearms of 30 subjects using the α Armband and extracted three different image samples from the time–frequency domain for training and testing convolutional neural networks. The average recognition accuracy for 10 hand gestures was as high as 98.6%, indicating that the α Armband is highly practical and robust, with excellent development potential.
In recent years, flexible pressure sensors have garnered significant attention. However, the development of large-area, low-cost, and easily fabricated flexible pressure sensors remains challenging. We designed a flexible fiber optic pressure sensor for contact force detection based on the principle of backward Rayleigh scattering using a single-mode optical fiber as the sensing element and polymer PDMS as the encapsulation material. To enhance the sensor’s sensitivity and stability, we optimized its structural design, parameters, and fabrication process and measured the fiber strain using an optical frequency domain reflectometer (OFDR). The results showed that the sensor achieved a high sensitivity of 6.93247 με/kPa with a PDMS concentration ratio of 10:1, a curing time of 2 h, and a substrate thickness of 5 mm. The sensor demonstrated excellent linearity and repeatability in static performance tests and was successfully used to monitor the plantar pressure distribution in real time. This flexible fiber optic pressure sensor can be developed via a simple fabrication process, has a low cost, and has high sensitivity, highlighting its potential applications in smart wearables and medical diagnostics.
The ultrasonic Lamb wave detection principle can realize the noncontact measurement of liquid level in closed containers. When designing an ultrasonic Lamb wave sensor, it is vital to thoroughly study and select the optimal wedge size at the front of the sensor. In this paper, firstly, we select the best working mode of Lamb waves according to their propagation dispersion curve in aluminum alloy, and we obtain the best angle of wedge through experiments. Secondly, we study the impact of the size of the wedge block on the results, and we obtain the selection method of wedge block parameters. The evaluations show that, when the frequency–thickness product is 3 MHz·mm, the Lamb waves work in the A1 mode, and the experimental effect is the best. At this time, the incident angle of the ultrasonic wave is 27.39°. The wedge thickness should be designed to avoid the near-field area of the ultrasonic field, and we should choose the length as odd multiples of 1/4 wavelength. The rules obtained from the experiment can effectively select the best working mode for ultrasonic Lamb waves, while also providing a basis for the design of the wedge block size in a Lamb wave sensor.