The accumulation of electronic waste (E-waste) has become a significant global environmental issue, driven by the characteristics of the modern era and the ever-increasing use of electronic devices. Thus, a sustainable approach is necessary to overcome this issue. In this paper, an overview of utilizing E-waste as a sustainable aggregate in concrete production was comprehensively reviewed. The basic composition, characteristics, and production techniques were discussed. In addition to that, the colour, shape, size, aggregate crushing value, and water absorption of E-waste concrete were also discussed. Furthermore, the workability properties such as slump flow, mechanical properties (compressive strength, flexural strength, tensile strength) and thermal resistance of E-waste concrete identified by the various researchers were summarised. Based on the literature review, it is concluded that the shape and size distributions of E-waste particles greatly influenced the aggregate properties, and the percentage of replacement of E-waste aggregate affect the workability and mechanical and thermal properties of E-waste concrete.
This study explores the use of embedded piezo sensor (EPS) employing the Electro-Mechanical Impedance (EMI) technique for real-time corrosion monitoring in reinforced E-waste concrete exposed to chloride-laden environments. With the growing environmental concerns over electronic waste (E-waste) and the demand for sustainable construction practices, printed circuit board (PCB) materials were incorporated as partial replacements for coarse aggregates in concrete. The experiment utilized M30-grade concrete mixes, substituting 15% of natural coarse aggregates with E-waste, aiming to assess both sustainability and structural performance without compromising durability. EPS configured with Lead Zirconate Titanate (PZT) patches were embedded into both conventional and E-waste concrete specimens. The EPS monitored the changes in the form of conductance and susceptance signatures across a 100–400 kHz frequency range during accelerated corrosion exposure over a 60-day period in a 3.5% NaCl solution. The corrosion progression was evaluated qualitatively through electrical impedance signatures, visually via rust formation and cracking, and quantitatively using the Root Mean Square Deviation (RMSD) of EMI signatures. The results showed that the EMI technique effectively captured the initiation and propagation stages of corrosion. E-waste concrete exhibited earlier and more severe signs of corrosion compared to conventional concrete, indicated by faster increases and subsequent declines in conductance and susceptance and higher RMSD values during the initiation phase. The EMI-based system demonstrated its capability to detect microstructural changes at early stages, making it a promising method for Structural Health Monitoring (SHM) of sustainable concretes. The study concludes that while the use of E-waste in concrete contributes positively to sustainability, it may compromise long-term durability in aggressive environments. However, the integration of EPS and EMI offers a reliable, non-destructive, and sensitive technique for real-time corrosion monitoring, supporting preventive maintenance and improved infrastructure longevity.