Hanglin Lu

Dr. Hanglin Lu

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2024 in Optics & Laser Technology
Verified
Journal Article
Closed access
DZDongjiang Zou
Dongjiang Zou
ZSZhuo Song
Zhuo Song
CLChaoping Liang
Chaoping Liang
HLHanglin Lu
Hanglin Lu
RWRuoxue Wei
Ruoxue Wei
JHJunhui Hu
Junhui Hu

12 September 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
TLTian Li
Tian Li
GLGe Liu
Ge Liu
HLHanglin Lu
Hanglin Lu
DZDongjiang Zou
Dongjiang Zou
ZSZhuo Song
Zhuo Song
JHJunhui Hu
Junhui Hu
Phase-sensitive optical time domain reflectometry (φ-OTDR) can be used to recover external vibration information through phase demodulation. However, with the restriction of the unwrapping algorithm, traditional φ-OTDR can not demodulate signals correctly when the external dynamic strain is large. To solve this problem, an φ-OTDR system with time-delay double probe pulses scheme is proposed and demonstrated in this paper. In the scheme, time-delay double probe pulses with different frequency are employed, the phase signals with large dynamic strain can be effectively restored by subtracting the two phase signals of Rayleigh backscattered (RBS) signals arise from the time-delay double probe pulses. In our scheme, the digital correction method is also used to eliminate the influence of disturbance frequency on the demodulation results. The simulation and experimental results show that the system can measure vibration amplitude of 15.55 με, the vibration frequency of 800 Hz, the spatial resolution of 5 m. And then the strain range of 7.55 με to 15.55 με disturbance signals are successfully recovered on a 2 km single-mode fiber. The maximum measured dynamic strain is 58 times that of conventional φ-OTDR, and which is limited to the amplitude of the existing piezoelectric transducer (PZT) in our laboratory. Moreover, the sensor can work while vibration frequency ranges from 200 Hz to 1.4 kHz under large stain in experiments and the phase difference is linear with the value of time-delay. The proposed method will extend the scope of application fields of φ-OTDR, in which requires large dynamic strain recognition.

12 September 2025 in Sensors
Verified
Journal Article
Open access
PDF file
MLMin Lu
Min Lu
YHYan He
Yan He
SXShuyu Xi
Shuyu Xi
PZPufan Zhong
Pufan Zhong
YZYu Zhang
Yu Zhang
JTJian Tang
Jian Tang
Early detection of cancer remains a key challenge because current SPR-PCF sensors lack both sensitivity and robust light–analyte interaction. To overcome these limitations, this study proposed and validated an SPR biosensor utilizing MXene-functionalized PCF. By introducing a composite structure of MXene nanomaterials and Au, the detection performance of the sensor was significantly improved. The sensor adopts a circular air hole arrangement and double-groove morphology design and leverages MXene’s high conductivity and gold’s chemical stability to simultaneously enhance plasmonic coupling and biocompatibility. Through FEM-based structural optimization of the air hole diameter, Au layer thickness, and groove shape, the sensor exhibited outstanding refractive-index detection performance with a wavelength sensitivity of 11,072 nm/RIU, an impressive quality factor reaching 201.3 RIU−1, and a resolution as fine as 9.03 × 10−6 RIU. The simulation results demonstrated the capability of the sensor to discriminate six distinct cancer-cell types (cervical cancer HeLa, leukemia Jurkat, pheochromocytoma PC-12, triple-negative breast cancer MDA-MB-231, and breast cancer MCF-7) with high sensitivity and verify its ability to detect pan-cancer species. This study demonstrates an innovative approach for constructing a high-performance SPR sensing platform that has important application potential in the context of the early detection of multiple cancers.

29 August 2025 in Optics Express
Verified
Journal Article
Closed access
YNYalan Niu
Yalan Niu
HZHaojie Zhong
Haojie Zhong
JLJingjing Li
Jingjing Li
ZLZhan Liao
Zhan Liao
LYLi Yang
Li Yang
JHJunhui Hu
Junhui Hu
In this paper, a high-temperature optical fiber structure sensor based on Mach-Zehnder interference has been proposed and experimentally validated. The sensor is constructed via the fusion-splicing of a segment of coreless fiber (CLF) with a piece of seven-core fiber (SCF), followed by fusion-splicing another section of coreless fiber that links two single-mode fiber (SMF) structures. This configuration provides a single-mode fiber/coreless fiber/seven-core fiber/coreless fiber/single-mode fiber (SCSCS) optical fiber structure. The high-temperature characteristics of this sensor have been examined via an experiment. The results indicate that the length of the seven-core optical fiber has a minimal impact on the sensitivity spectrum to temperature. It is also shown that the sensor demonstrates excellent repeatability and stability. The sensor can withstand temperatures up to 1000 °C, and has a sensitivity of 0.026 nm/°C. The standard deviation of stability is 0.167, while the sensor exhibits good periodicity. This proposed sensor has significant potential for applications in high-temperature environments such as aviation, aerospace, and mineral mining.

19 September 2024 in Optics Express
Verified
Journal Article
Closed access
CLChao Ping Liang
Chao Ping Liang
ZSZhuo Song
Zhuo Song
HCHong Dong Chen
Hong Dong Chen
DZDong Jiang Zou
Dong Jiang Zou
CHChuan Yang Huang
Chuan Yang Huang
JHJunhui Hu
Junhui Hu
A distributed optical fiber sensor for salinity sensing is proposed and analyzed. The sensor uses a single mode fiber coated with polyimide and is based on optical frequency domain reflectometry. By applying the polyimide solution to the surface of the fiber, a layer of polyimide film is formed by heating. As the polyimide coating is very sensitive to changes in the salinity of the external solution, the polyimide film will expand or shrink as the external concentration changes. This converts the value of salt concentration into the frequency shift in the spectrum through cross-correlation. To characterize the sensor, four polyimide-coated sensors with different average coating thicknesses of 126 µm, 170 µm, 192 µm and 249 µm were fabricated. The sensitivities of -21.71 GHz/(mol/L), -28.55 GHz/(mol/L), -29.97 GHz/(mol/L) and -42.78 GHz/(mol/L) were achieved when the salinity was measured from 0 mol/L to 3.09 mol/L, respectively. The sensitivity and response time of polyimide fibers with different diameters were measured. The minimum salinity measurement uncertainty of the sensor is 0.05 mol/L. The sensor has high sensitivity and has promising applications in observing ocean parameters and ion chemical sensing.

11 February 2025 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
ZSZhuo Song
Zhuo Song
CLChaoping Liang
Chaoping Liang
DZDongjiang Zou
Dongjiang Zou
HCHongdong Chen
Hongdong Chen
SLSongwei Li
Songwei Li
JHJunhui Hu
Junhui Hu
Photosensitive polymers serve as critical adhesives in optical devices, with their thermal strain coefficient determining the performance of temperature-dependent loss in such devices. To accurately measure the true thermal strain coefficient of the adhesive, we proposed a measurement scheme of internal strain distribution in photosensitive polymers by using an optical frequency domain reflectometry (OFDR) system. In our scheme, a self-referencing approach is used to eliminate the temperature-to-strain crosstalk caused by temperature variations in the tested sample, thereby obtaining the true thermal strain coefficient of the tested sample. In our experiment, a 10 cm single-mode fiber (SMF) is embedded within the 2 mm × 2 mm × 100 mm photosensitive polymer, and we use the high spatial resolution of the OFDR system to realize the distributed strain measurements of the SMF. A thermal strain coefficient of 19.108 μϵ/°C is obtained when the temperature ranges from 30 °C to 120 °C. The temperature-to-strain crosstalk is 9.131 μϵ/°C, and the spatial resolution of the OFDR is 1.28 mm. In addition, we validated the stability of the entire experimental setup by conducting long-term measurements under fixed environmental conditions, during which the system fluctuations remained within approximately ± 3 GHz. The experimental results can provide valuable insights for the selection of adhesives and the determination of optimal curing time of the passive optical devices fabrication in the field of optical fiber communication.