Mónica Rojas-Martínez

Dr. Mónica Rojas-Martínez

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2012 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
MRMónica Rojas-Martínez
Mónica Rojas-Martínez
MVMiquel Angel Mañanas Villanueva
Miquel Angel Mañanas Villanueva
JAJoan Francesc Alonso
Joan Francesc Alonso
Background: sEMG signal has been widely used in different applications in kinesiology and rehabilitation as well as in the control of human-machine interfaces. In general, the signals are recorded with bipolar electrodes located in different muscles. However, such configuration may disregard some aspects of the spatial distribution of the potentials like location of innervation zones and the manifestation of inhomogineties in the control of the muscular fibers. On the other hand, the spatial distribution of motor unit action potentials has recently been assessed with activation maps obtained from High Density EMG signals (HD-EMG), these lasts recorded with arrays of closely spaced electrodes. The main objective of this work is to analyze patterns in the activation maps, associating them with four movement directions at the elbow joint and with different strengths of those tasks. Although the activation pattern can be assessed with bipolar electrodes, HD-EMG maps could enable the extraction of features that depend on the spatial distribution of the potentials and on the load-sharing between muscles, in order to have a better differentiation between tasks and effort levels. Methods: An experimental protocol consisting of isometric contractions at three levels of effort during flexion, extension, supination and pronation at the elbow joint was designed and HD-EMG signals were recorded with 2D electrode arrays on different upper-limb muscles. Techniques for the identification and interpolation of artifacts are explained, as well as a method for the segmentation of the activation areas. In addition, variables related to the intensity and spatial distribution of the maps were obtained, as well as variables associated to signal power of traditional single bipolar recordings. Finally, statistical tests were applied in order to assess differences between information extracted from single bipolar signals or from HD-EMG maps and to analyze differences due to type of task and effort level. Results: Significant differences were observed between EMG signal power obtained from single bipolar configuration and HD-EMG and better results regarding the identification of tasks and effort levels were obtained with the latter. Additionally, average maps for a population of 12 subjects were obtained and differences in the co-activation pattern of muscles were found not only from variables related to the intensity of the maps but also to their spatial distribution. Conclusions: Intensity and spatial distribution of HD-EMG maps could be useful in applications where the identification of movement intention and its strength is needed, for example in robotic-aided therapies or for devices like powered- prostheses or orthoses. Finally, additional data transformations or other features are necessary in order to improve the performance of tasks identification.

1 February 2013 in Journal of Electromyography and Kinesiology
Verified
Journal Article
Closed access
MRMónica Rojas-Martínez
Mónica Rojas-Martínez
MVMiquel Angel Mañanas Villanueva
Miquel Angel Mañanas Villanueva
JAJoan Francesc Alonso
Joan Francesc Alonso
RMR. Merletti
R. Merletti

23 June 2011 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
Hamid reza MaratebHamid reza Marateb
Hamid reza Marateb
MRMónica Rojas-Martínez
Mónica Rojas-Martínez
MMMarjan Mansourian
Marjan Mansourian
RMRoberto Merletti
Roberto Merletti
MVMiguel A. Mañanas Villanueva
Miguel A. Mañanas Villanueva

29 April 2016 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
MJMislav Jordanić
Mislav Jordanić
MRMónica Rojas-Martínez
Mónica Rojas-Martínez
MVMiquel Angel Mañanas Villanueva
Miquel Angel Mañanas Villanueva
JAJoan Francesc Alonso
Joan Francesc Alonso
Recent studies show that spatial distribution of High Density surface EMG maps (HD-EMG) improves the identification of tasks and their corresponding contraction levels. However, in patients with incomplete spinal cord injury (iSCI), some nerves that control muscles are damaged, leaving some muscle parts without an innervation. Therefore, HD-EMG maps in patients with iSCI are affected by the injury and they can be different for every patient. The objective of this study is to investigate the spatial distribution of intensity in HD-EMG recordings to distinguish co-activation patterns for different tasks and effort levels in patients with iSCI. These patterns are evaluated to be used for extraction of motion intention. HD-EMG was recorded in patients during four isometric tasks of the forearm at three different effort levels. A linear discriminant classifier based on intensity and spatial features of HD-EMG maps of five upper-limb muscles was used to identify the attempted tasks. Task and force identification were evaluated for each patient individually, and the reliability of the identification was tested with respect to muscle fatigue and time interval between training and identification. Three feature sets were analyzed in the identification: 1) intensity of the HD-EMG map, 2) intensity and center of gravity of HD-EMG maps and 3) intensity of a single differential EMG channel (gold standard). Results show that the combination of intensity and spatial features in classification identifies tasks and effort levels properly (Acc = 98.8 %; S = 92.5 %; P = 93.2 %; SP = 99.4 %) and outperforms significantly the other two feature sets (p < 0.05). In spite of the limited motor functionality, a specific co-activation pattern for each patient exists for both intensity, and spatial distribution of myoelectric activity. The spatial distribution is less sensitive than intensity to myoelectric changes that occur due to fatigue, and other time-dependent influences.

16 November 2020 in Scientific Data
Verified
Journal Article
Open access
PDF file
MRMónica Rojas-Martínez
Mónica Rojas-Martínez
YSYanet Serna
Yanet Serna
MJMislav Jordanić
Mislav Jordanić
Hamid reza MaratebHamid reza Marateb
Hamid reza Marateb
RMRoberto Merletti
Roberto Merletti
MVMiquel Angel Mañanas Villanueva
Miquel Angel Mañanas Villanueva
This paper presents a dataset of high-density surface EMG signals (HD-sEMG) designed to study patterns of sEMG spatial distribution over upper limb muscles during voluntary isometric contractions. Twelve healthy subjects performed four different isometric tasks at different effort levels associated with movements of the forearm. Three 2-D electrode arrays were used for recording the myoelectric activity from five upper limb muscles: biceps brachii, triceps brachii, anconeus, brachioradialis, and pronator teres. Technical validation comprised a signals quality assessment from outlier detection algorithms based on supervised and non-supervised classification methods. About 6% of the total number of signals were identified as “bad” channels demonstrating the high quality of the recordings. In addition, spatial and intensity features of HD-sEMG maps for identification of effort type and level, have been formulated in the framework of this database, demonstrating better performance than the traditional time-domain features. The presented database can be used for pattern recognition and MUAP identification among other uses.

8 July 2017 in Sensors
Verified
Journal Article
Open access
PDF file
MJMislav Jordanić
Mislav Jordanić
MRMónica Rojas-Martínez
Mónica Rojas-Martínez
MVMiquel Angel Mañanas Villanueva
Miquel Angel Mañanas Villanueva
JAJoan Francesc Alonso
Joan Francesc Alonso
Hamid reza MaratebHamid reza Marateb
Hamid reza Marateb
Estimation of neuromuscular intention using electromyography (EMG) and pattern recognition is still an open problem. One of the reasons is that the pattern-recognition approach is greatly influenced by temporal changes in electromyograms caused by the variations in the conductivity of the skin and/or electrodes, or physiological changes such as muscle fatigue. This paper proposes novel features for task identification extracted from the high-density electromyographic signal (HD-EMG) by applying the mean shift channel selection algorithm evaluated using a simple and fast classifier-linear discriminant analysis. HD-EMG was recorded from eight subjects during four upper-limb isometric motor tasks (flexion/extension, supination/pronation of the forearm) at three different levels of effort. Task and effort level identification showed very high classification rates in all cases. This new feature performed remarkably well particularly in the identification at very low effort levels. This could be a step towards the natural control in everyday applications where a subject could use low levels of effort to achieve motor tasks. Furthermore, it ensures reliable identification even in the presence of myoelectric fatigue and showed robustness to temporal changes in EMG, which could make it suitable in long-term applications.