David Honan

Mr. David Honan

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2024 in Buildings
Verified
Journal Article
Open access
PDF file
DHDavid Honan
David Honan
JGJohn Gallagher
John Gallagher
JGJohn Garvey
John Garvey
JLJohn Littlewood
John Littlewood
Indoor air quality (IAQ) in schools significantly impacts occupant health and academic performance, especially in naturally ventilated (NV) classrooms, where CO2 levels are often elevated. This systematic review synthesises findings from 125 studies, examining CO2 as an indicator of ventilation rates (VRs) and its impact on IAQ, health, and academic performance in NV primary school classrooms. This analysis highlights seasonal and temporal variations in CO2 concentrations, revealing a median CO2 concentration of 1487 ppm across 2444 classrooms, with 81% exceeding the recommended 1000 ppm threshold. Influencing factors include VR, occupant density, generation rates, and occupant behaviours. Increased VRs consistently lowered CO2 levels and enhanced IAQ. CO2 concentrations correlated with particulate matter, volatile organic compounds, bioeffluents, microbial concentrations, and bacteria and fungi levels, but not with traffic-related pollutants like NO2, which is associated with asthma prevalence. Elevated CO2 levels consistently correlated with fatigue, headaches, respiratory symptoms, reduced academic performance and absenteeism, suggesting potential socio-economic benefits of increased VRs. However, effective IAQ management requires balancing ventilation with considerations of thermal comfort, noise, and outdoor pollutants. The findings highlight the need for standardised IAQ indices and CO2 monitoring protocols, offering insights for future research, intervention design, and investment aimed at enhancing classroom environments.

1 October 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
KMKelly Maguire
Kelly Maguire
NONoelle O'Connor
Noelle O'Connor
RCRedmond Condron
Redmond Condron
PAPaul Archbold
Paul Archbold
CHChristoffer Hannevig
Christoffer Hannevig
DHDavid Honan
David Honan
The purpose of this research is to examine current alignment of tourism, hospitality, culinary, events, and sports management curriculum with the United Nations Sustainable Development Goals (SDG’s) across two departments in Higher Education Institutions in Ireland. To do this, a quantitative approach was adopted utilising a content analysis of programme learning outcomes and surveys with programme specific educators. This permitted an evaluation on the current status of incorporation of SDG’s within existing curricula and an insight into the motivations and challenges of Education for Sustainable Development (ESD) integration from the perspective of educators. Findings revealed weak levels of current alignment of learning outcomes to SDG’s for tourism, hospitality, culinary, events, and sports management curriculum across two sampled departments while educators emphasised a need to upskill on the subject matter in an effort to ensure more comprehensive ESD integration across modules and programmes. The Results overall highlighted the need to ensure future curriculum review and development takes appropriate cognisance of ESD and through communities of Practice within Higher Education Institutions, educators can better embed and advance ESD within third level curricula. The findings presented in this study may have lessons to be learned for other Higher Education Institutions across Ireland and internationally.

15 February 2026 in Sensors
Verified
Journal Article
Open access
PDF file
DHDavid Honan
David Honan
JGJohn Garvey
John Garvey
JLJohn Littlewood
John Littlewood
MHMatthew Horrigan
Matthew Horrigan
JGJohn Gallagher
John Gallagher
Adequate ventilation is essential for maintaining indoor environmental quality in schools, where ventilation standards are often based on an indoor concentration of human-generated carbon dioxide (CO2) above ambient levels. Low-cost non-dispersive infrared (NDIR) CO2 sensors offer a practical solution for ventilation monitoring, yet variability between sensors can compromise accuracy, particularly when applications depend on the determination of precise concentration differences. This study evaluates the performance of twenty-three low-cost CO2 sensors, developing normalisation functions to improve comparability across sensors, introducing an accessible methodology for on-site sensor calibration without the need for laboratory-grade reference equipment. The sensors were co-located for three independent test periods in 2025 representing typical school internal conditions in Ireland. Pre-normalisation analysis showed strong linearity (coefficient of determination (R2) = 0.999) but notable variability, with a mean root mean square error (RMSE) of 18.3 ppm and 0.45% of measurements outside manufacturers stated accuracy. Normalisation models were trained and validated using a leave-one-period-out approach. Regression-based correction yielded the greatest improvement, reducing RMSE by 16%. When applied to the full dataset, final correction factors reduced RMSE by 27%, out-of-range measurements by 43%, and proportional bias by 31%. Corrected sensors demonstrated highly consistent performance, particularly within the CO2 ranges most relevant for classroom ventilation assessment, with an RMSE = 7.4 parts per million (ppm) at ambient concentrations and 11.9 ppm at concentrations below 1500 ppm. Field-based co-location in the deployment environment across full CO2 cycles, combined with a network-derived global reference, produced effective correction factors. Performance declined marginally above 1500 ppm and during dynamic occupancy, while overall accuracy remained strong. The study presents a practical and accessible methodology for evaluating and normalising low-cost CO2 sensors without specialised laboratory equipment, supporting reliable ventilation assessments in schools.

5 November 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
DHDavid Honan
David Honan
JGJohn Garvey
John Garvey
JLJohn Littlewood
John Littlewood
MHMatthew Horrigan
Matthew Horrigan
JGJohn Gallagher
John Gallagher
Indoor air quality (IAQ) and thermal comfort influence the health and cognitive performance of school occupants. This study investigated carbon dioxide (CO2), nitrogen dioxide (NO2), thermal comfort, and ventilation rates (VRs) in eight naturally ventilated (NV) primary school classrooms in Ireland during October 2024, combining environmental monitoring with teacher surveys. Mean CO2 concentrations ranged from 796 ppm to 2469 ppm, exceeding national guidelines in seven of the eight classrooms. NO2 levels ranged from 3.4 µg/m3 to 7.2 µg/m3, with indoor/outdoor ratios increasing with VRs and influenced by window orientation and road proximity. Indoor temperatures remained within recommended limits, while relative humidity ranged from 53% to 78% mirroring CO2 trends and exceeding guideline levels in classrooms with lower VRs and temperatures. Occupied VRs ranged from 1.2 L/p/s to 4.1 L/p/s with window opening behaviours, reliant on teachers’ perceptions of thermal comfort, accounting for 84% to 96% of VRs. Ventilation in NV classrooms is often insufficient, yet increasing VRs can compromise thermal comfort and increase ingress of outdoor pollutants and noise. The findings highlight the ineffectiveness of current school ventilation standards, which rely heavily on user operation. Integrating occupant-led strategies, including scheduled purging, awareness campaigns, and pre-emptive air quality alerting, into policy offers practical, immediate pathways to improving IAQ, fostering healthy, sustainable learning environments.