Choi Choi

Dr. Choi Choi


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 March 2023 in Metals
Verified
Journal Article
Open access
PDF file
YYYoung Ran Yoo
Young Ran Yoo
CCChoi Choi
Choi Choi
Young Sik KimYoung Sik Kim
Young Sik Kim
Storage canisters used in nuclear power plants operating in seaside areas—where the salt content in the atmosphere is high—may be susceptible to chloride-induced stress corrosion cracking (CISCC). Chloride-induced stress corrosion cracking is one of the ways in which dry storage canisters made of stainless steel can degrade. Stress corrosion cracking depends on the microstructure and residual stress, and it is therefore very important to improve the surface properties of materials. Laser shock peening both greatly deforms the material surface and refines grains, and it generates compressive residual stress in the deep part from the surface of the material. This study focused on the effect of laser shock peening on the stress corrosion cracking of 304L stainless steel. The laser shock peening was found to induce compressive residual stress from the surface to a 1 mm depth, and the SCC properties were evaluated by a U-bend test. The results showed that the SCC resistance of laser-peened 304L stainless steel in a chloride environment was enhanced, and that it was closely related to grain size, the pitting potential of the cross section, and residual stress.

13 January 2023 in Materials
Verified
Journal Article
Open access
PDF file
YYYoung Ran Yoo
Young Ran Yoo
CCChoi Choi
Choi Choi
Young Sik KimYoung Sik Kim
Young Sik Kim
Dry canisters used in nuclear power plants can be subject to localized corrosion, including stress corrosion cracking. External and residual tensile stress can facilitate the occurrence of stress corrosion cracking. Residual stress can arise from welding and plastic deformation. Mitigation methods of residual stress depend upon the energy used and include laser peening, ultrasonic peening, ultrasonic nanocrystal surface modification, shot peening, or water jet peening. Among these, laser peening technology irradiates a continuous laser beam on the surface of metals and alloys at short intervals to add compressive residual stress as a shock wave is caused. This research studied the effect of laser peening with/without a thin aluminum layer on the corrosion properties of welded 304L stainless steel. The intergranular corrosion rate of the laser-peened specimen was a little faster than the rate of the non-peened specimen. However, laser peening enhanced the polarization properties of the cross-section of 304L stainless steel, while the properties of the surface were reduced by laser peening. This behavior was discussed on the basis of the microstructure and residual stress.

28 August 2024 in Crystals
Verified
Journal Article
Open access
PDF file
CCChoi Choi
Choi Choi
YYYoung Ran Yoo
Young Ran Yoo
Young Sik KimYoung Sik Kim
Young Sik Kim
Stainless steel is widely used in various industrial fields due to its excellent corrosion resistance and mechanical properties. The key to this corrosion resistance is the thin passive film that naturally forms on the metal surface. Passive films are characterized by oxide film theory and adsorption theory, each uniquely explaining the structure and mechanism of the protective film on the metal surface. Research on the semiconductive properties of passive films on stainless steel offers diverse viewpoints, classifying theories into the point defect model and the bipolar fixed charge-induced passivity. Specific changes in passive film attributes that lead to degradation, however, are not fully understood. In this study, we analyzed the inner and outer layers of the passive film on super austenitic stainless steel SR-50A under various conditions in acidic and alkaline chloride environments. The interpretations of these results were based on the point defect model and the bipolar model for the passivation mechanism, and correlations between p-type and n-type semiconductor properties and passivation behavior were examined. The surface of the stainless steel forms a passive film comprising two layers with p-type and n-type semiconductive properties, independent of the pH of the solutions. The corrosion resistance increases as the p-type and n-type semiconductive tendencies become more balanced, consequently enhancing the properties of the passive film.

14 August 2025 in Crystals
Verified
Journal Article
Open access
PDF file
CCChoi Choi
Choi Choi
YYYoung-Ran Yoo
Young-Ran Yoo
YKYoung-Cheon Kim
Young-Cheon Kim
YKYoung-Sik Kim
Young-Sik Kim
This study investigated the influence of Cr, Mo, and W alloying elements incorporated into ferritic stainless steel on the characteristics of passive films formed under acidic chloride conditions. Electrochemical assessments demonstrated that increasing the amounts of Cr, Mo, and W reduces passive current density and enhances polarization resistance. Through XPS analysis, it was determined that the passive film exhibits a double-layer structure, consisting of an inner layer rich in metal oxides and an outer layer containing metal oxy-anions. Mott–Schottky analysis indicated the presence of both p-type and n-type semiconducting properties. To clarify the effect of these alloying elements on the passive films at the surface of stainless steel, this work introduces a new parameter termed the “Bipolar Index,” defined as |p-type slope| + |n-type slope|. With higher Cr, Mo, and W contents, the bipolar index increases, reflecting modifications in the semiconductive behavior. Consequently, the point defect concentration within the passive film decreases, causing a reduction in passive current density and a rise in polarization resistance.

5 December 2024 in Materials
Verified
Journal Article
Open access
PDF file
CCChoi Choi
Choi Choi
YYYoung Ran Yoo
Young Ran Yoo
Young Sik KimYoung Sik Kim
Young Sik Kim
Duplex stainless steels, known for their excellent corrosion resistance, are employed in a variety of chloride solutions—acidic, neutral, and alkaline—due to a stable passive film that forms on their surfaces. This study involved polarization tests, EIS (Electrochemical Impedance Spectroscopy) measurements, Mott–Schottky plots, and XPS (X-Ray Photoelectron Spectroscopy) analyses in both static and dynamic conditions across acidic (1NaCl + 0.1N HCl, pH 1.0), neutral (1N NaCl, pH 6.7), and alkaline (1N NaCl + 0.1N NaOH, pH 13.2) chloride solutions to confirm that duplex stainless steels exhibit similar passivation behavior (0.79 μA/cm2 > ip > 0.2 μA/cm2 and 590 kΩ·cm2 < Rp < 651 kΩ·cm2). Regardless of the pH of the solution, p-type and n-type semiconductive properties were observed, but the balance of the semiconductive tendencies was different. Comparing passive films formed under dynamic conditions, through real-time HCl injection into a neutral chloride solution, with those formed under static conditions, revealed that both conditions yield similar structural and property characteristics in the films, as well as comparable electrochemical behaviors. These findings suggest that the passive film on the stainless steel surface adjusts to the environment and can be spontaneously repassivated in response to environmental changes.

21 August 2023 in Coatings
Verified
Journal Article
Open access
PDF file
CCChoi Choi
Choi Choi
YYYoung Ran Yoo
Young Ran Yoo
Young Sik KimYoung Sik Kim
Young Sik Kim
Buried piping is subject to soil corrosion, which can be prevented by combining coatings and cathodic protection to maximize corrosion control. However, even with both methods, coatings are subject to damage from external factors and various causes. Buried piping may expose the metal and alter the current flow, which in turn causes corrosion. Therefore, this study analyzed the effect of detection electrode spacing on the direct current voltage gradient (DCVG) magnitude formed for coated pipelines buried in the soil. The DCVG was measured using a real-time coating defect detection system. FEM model simulations were carried out, and then the result was compared to the measured DCVG magnitude. When the spacing of the detection electrodes increased, the detected signal and signal location changed. The detection reliability increased as the noise signal is eliminated at the optimum detection electrode spacing. However, the detection reliability decreased at higher selection electrode spacing as the noise signal and detected signals together were eliminated. The location of the detected signal shifted as the spacing of the detection electrodes increased due to the change in the detection reference point and signal magnitude.