Mixing and matching components from different manufacturers in total hip arthroplasty is a frequently used off-label praxis. The clinical consequences of this procedure have not been studied in detail. 860 patients with matched and 1067 patients with mixed primary total hip replacement (THR) components carried out between 1 January 2002 and 31 December 2004, were selected from our Institution registry. The analysis endpoint was set at 1 January 2016. THRs with poorly performing components were excluded from study groups. Kaplan-Meier survival curves for both groups were calculated and compared using the Log-Rank test and the demographic data using the chi-square test. Correlations between demographic data and revisions were calculated using bivariate correlation. 28 revisions were carried out in the matched group and 67 in the mixed group. The 14-year overall survival probability was significantly better in the former (96.0%) than in the mixed group (92.7%) (p = 0.002). Survival, free of aseptic and septic failures, was statistically, significantly higher in the matched group (p = 0.026 and p = 0.007, respectively). The survival of the mixed subgroup with heads and stems from the same manufacturer did not differ statistically from that of the matched group (p = 0.079). In contrast to the results listed in the National Joint Registry and the New Zealand Joint Registry, the survival probability in our study was, statistically, significantly higher in total hip replacements using components of the same manufacturer. Importantly, mixing and matching the components of different manufacturers led to similar survival providing the head and the stem were from the same manufacturer.
(1) Background: Analyses of retrieved inserts allow for a better understanding of TKA failure mechanisms and the detection of factors that cause increased wear. The purpose of this implant retrieval study was to identify whether insert volumetric wear significantly differs among groups of common causes of total knee arthroplasty failure, whether there is a characteristic wear distribution pattern for a common cause of failure, and whether nominal insert size and component size ratio (femur-to-insert) influence linear and volumetric wear rates. (2) Methods: We digitally reconstructed 59 retrieved single-model cruciate-retaining inserts and computed their articular load-bearing surface wear utilizing an optical scanner and computer-aided design models as references. After comprehensively reviewing all cases, each was categorized into one or more of the following groups: prosthetic joint infection, osteolysis, clinical loosening of the component, joint malalignment or component malposition, instability, and other isolated causes. The associations between volumetric wear and causes of failure were estimated using a multiple linear regression model adjusted for time in situ. Insert linear penetration wear maps from the respective groups of failure were further processed and merged to create a single average binary image, highlighting a potential wear distribution pattern. The differences in wear rates according to nominal insert size (small vs. medium vs. large) and component size ratio (≤1 vs. >1) were tested using the Kruskal–Wallis test and the Mann–Whitney test, respectively. (3) Results: Patients with identified osteolysis alone and those also with clinical loosening of the component had significantly higher volumetric wear when compared to those without both causes (p = 0.016 and p = 0.009, respectively). All other causes were not significantly associated with volumetric wear. The instability group differentiated from the others with a combined peripheral antero-posterior wear distribution. Linear and volumetric wear rates showed no significant differences when compared by nominal insert size (small vs. medium vs. large, p = 0.563 and p = 0.747, respectively) or by component (femoral-to-insert) size ratio (≤1 vs. >1, p = 0.885 and p = 0.055, respectively). (4) Conclusions: The study found increased volumetric wear in cases of osteolysis alone, with greater wear when combined with clinical loosening compared to other groups. The instability group demonstrated a characteristic peripheral anterior and posterior wear pattern. Insert size and component size ratio seem not to influence wear rates.
Medenični obroč povezuje kot tečaj ledveno-križnično hrbtenico in kolke ter z ohranjanjem ledvene lordoze in ekstenzije v kolkih omogoča energetsko učinkovito stoječo držo. Razumevanje medsebojnega vpliva med hrbtenico in medenico je ključnega pomena pri načrtovanju in izvedbi totalne artroplastike kolka in/ali fiksacije ledveno-križnične hrbtenice. Z večanjem rigidnosti ledvene hrbtenice zmanjšujemo gibljivost hrbtenično-medeničnega kompleksa in povečujemo tveganje za utesnitev in izpah kolčne totalne endoproteze. Vpadni kot medenice je statični parameter, značilen za vsakega posameznika in klinično določa medsebojne vplive med hrbtenico in medenico. Primerjava drugih parametrov med stoječim in sedečim položajem omogoča oceno medenične gibljivosti v sagitalni ravnini. Sagitalna klasifikacija celotnega hrbteničnega stebra pri stoji in morfologija medenice pa določata obseg gibanja kolkov. Osebe z ožjo, bolj navpično medenico in nizkim vpadnim kotom ter naklonom križnice imajo omejeno medenično retroverzijo in hrbtenično-medenično gibljivost. To pa zahteva večjo gibljivost kolkov. Nasprotno pa imajo osebe s širšo in bolj vodoravno medenico ter višjim vpadnim kotom in naklonom križnice večjo sagitalno hrbtenično-medenično gibljivost. Zato potrebujejo prvi več anteverzije acetabularne komponente, drugi pa manj. Dobro gibljiva ledvena hrbtenica varuje kolčni sklep, medtem ko zahteva togi ledveno-križnični segment večjo kolčno gibljivost, kar lahko ogroža uspešnost totalne kolčne endoproteze. Čeprav enotnega soglasja še ni, pa se večina nedavnih smernic strinja, da je pri bolnikih z visokim tveganjem za izpah po totalni kolčni artroplastiki smiselno opraviti pred operacijo stranske rentgenske posnetke hrbtenično-medeničnega kompleksa stojé in sede. Tako lahko optimiziramo položaj acetabularne komponente pri nenormalni hrbtenično-medenični poravnavi ali gibljivosti ter zmanjšamo tveganje za izpah. V primeru, da je potrebna operacija tako kolčnega sklepa kot ledveno-križničnega prehoda, je priporočljivo najprej opraviti totalno kolčno artroplastiko. Izjema je prisotnost kompenzacijske retroverzije medenice, ko je za postavitev medenice v bolj fiziološko anteverzijo priporočljivo najprej operirati ledveno-križnično hrbtenico.