Ingrid Milosev

Dr. Ingrid Milosev

Department of Physical and Organic Chemistry, Jožef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia
orcid

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2000 in Biomaterials
Verified
Journal Article
Closed access
Ingrid MilosevIngrid Milosev
Ingrid Milosev
MMM. Metikoš-Huković
M. Metikoš-Huković
HSH.-H. Strehblow
H.-H. Strehblow

8 February 2018 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
Ingrid MilosevIngrid Milosev
Ingrid Milosev
GFG. S. Frankel
G. S. Frankel
There is a growing interest in conversion coatings based on titanium and/or zirconium as the result of the health and environmental issues associated with legacy chromate and phosphate conversion coatings. Any alternative technology should be environmentally friendly and cost effective, and also able to achieve comparable corrosion resistance and paint adhesion for ferrous and non-ferrous substrates. Conversion coatings based on titanium or zirconium seem to fulfill many of these requirements and thus offer a great potential for further applications. This literature review summarizes the scientific results in this rapidly growing area of research. Following the description of composition of conversion bath and deposition mechanism, the effects of process parameters for conversion baths such as pH, temperature, immersion time and agitation are presented together with coating characteristics. The effects of the type of substrate and substrate pre-treatment are explored for the most-studied substrates: Al alloys, zinc-coated steels and steels. Properties such as composition, morphology and thickness are summarized. The corrosion performance of the conversion coatings is discussed, as well as adhesion of organic coatings and delamination mechanism for a full coating system including substrate/coating/top-coat.

1 February 2021 in Corrosion Science
Verified
Journal Article
Open access
AKAnton Kokalj
Anton Kokalj
MLMatic Lozinšek
Matic Lozinšek
BKBarbara Kapun
Barbara Kapun
PTPeyman Taheri
Peyman Taheri
SNShova Neupane
Shova Neupane
Ingrid MilosevIngrid Milosev
Ingrid Milosev

1 June 2006 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
PDF file
Ingrid MilosevIngrid Milosev
Ingrid Milosev
rihard trebserihard trebse
rihard trebse
SKSimon Kovač
Simon Kovač
ACAndrej Cör
Andrej Cör
VPVenčeslav Pišot
Venčeslav Pišot
Background: Second-generation metal-on-metal total hip replacements were introduced in the early 1990s with the aim of eliminating polyethylene wear and the resulting complications of osteolysis and aseptic loosening. The goal of the present study was to evaluate the intermediate-term results in a series of patients who were managed with one of these implants. Methods: Between 1994 and 2002, we performed 640 total hip replacements in 591 patients with use of a Bicon-Plus cementless threaded cup with a polyethylene liner housing a metal inlay made of Sikomet low-carbon cobalt-chromium-molybdenum alloy that articulates with a Sikomet metal femoral head. Clinical and radiographic evaluation was performed retrospectively at a mean of 7.1 years postoperatively. Histologic analysis was performed on specimens retrieved from seventeen hips that were revised, and wear measurements were made for six hips that were revised. Results: Thirty-four hips (thirty-four patients) were revised because of infection (six hips), aseptic loosening (twenty-three hips), pain without loosening (two hips), or other reasons (three hips). The survival rate of the prosthesis as a whole at ten years, with revision for any reason as the end point, was 0.91 (95% confidence interval, 0.88 to 0.95). The survival rate of the cup was 0.94 (95% confidence interval, 0.90 to 0.97), and that of the stem was 0.96 (95% confidence interval, 0.94 to 0.98). Linear or expansile osteolysis, or both, was observed on the radiographs of sixteen (64%) of the twenty-five hips that were revised because of aseptic loosening and/or pain. Histological analysis of pericapsular tissue was performed for seventeen of the twenty-five hips that were revised because of aseptic loosening and/or pain. Thirteen of these seventeen hips demonstrated a hypersensitivity-like reaction with aseptic inflammatory changes accompanied by moderate to extensive diffuse and perivascular infiltration of lymphocytes. In the six retrieved specimens that were subjected to wear analysis, the main wear mode was abrasive wear. The mean cumulative linear wear for the bearing was 31.3 μm, and the mean annual wear rate was 6.3 μm/yr. The mean clearance was 87.6 μm. Conclusions: After a mean duration of follow-up of seven years, aseptic loosening was the major reason for failure of Sikomet metal-on-metal prostheses. The histological findings and the prevalence of osteolysis suggest the possibility of a hypersensitivity-like immunological response to wear particles. Level of Evidence: Therapeutic Level IV. See Instructions to Authors for a complete description of levels of evidence.

1 September 2015 in Corrosion Science
Verified
Journal Article
Closed access
Ingrid MilosevIngrid Milosev
Ingrid Milosev
NKNataša Kovačević
Nataša Kovačević
JKJanez Kovač
Janez Kovač
AKAnton Kokalj
Anton Kokalj

1 November 2000 in Journal of Biomedical Materials Research
Verified
Journal Article
Closed access
PDF file
Ingrid MilosevIngrid Milosev
Ingrid Milosev
HSHans‐Henning Strehblow
Hans‐Henning Strehblow