Yao Yu

Yao Yu


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 September 2024 in Animals
Verified
Journal Article
Open access
PDF file
CHChangzeng Hu
Changzeng Hu
LLLihua Li
Lihua Li
YJYuchen Jia
Yuchen Jia
ZXZongkui Xie
Zongkui Xie
YYYao Yu
Yao Yu
LHLimin Huo
Limin Huo
Mechanical ventilation is an important means of environmental control in multitier laying hen cages. The mainstream ventilation mode currently in use, negative-pressure ventilation (NPV), has the drawbacks of a large temperature difference before and after adjustment and uneven air velocity distribution. To solve these problems, this study designed and analyzed a combined positive and negative-pressure ventilation system for laying hen cages. According to the principle of the conservation of mass to increase the inlet flow in the negative-pressure ventilation system on the basis of the addition of the pressure-wind body-built positive-and-negative-pressure-combined ventilation (PNCV) system, further, computational fluid dynamics (CFD) simulation was performed to analyze the distribution of environmental parameters in the chicken cage zone (CZ) with inlet angles of positive-pressure fans set at 45°, 90°, and 30°. Simulation results showed that the PNCV system increased the average air velocity in the CZ from 0.94 m/s to 1.04 m/s, 1.28 m/s, and 0.99 m/s by actively blowing air into the cage. The maximum temperature difference in the CZ with the PNCV system was 2.91 °C, 1.80 °C, and 3.78 °C, which were all lower than 4.46 °C, the maximum temperature difference in the CZ with the NPV system. Moreover, the relative humidity remained below 80% for the PNCV system and between 80% and 85% for the NPV system. Compared with the NPV system, the PNCV system increased the vertical airflow movement, causing significant cooling and dehumidifying effects. Hence, the proposed system provides an effective new ventilation mode for achieving efficient and accurate environmental control in laying hen cages.

23 October 2024 in Animals
Verified
Journal Article
Open access
PDF file
LLLihua Li
Lihua Li
MLMin Li
Min Li
YYYao Yu
Yao Yu
YJYuchen Jia
Yuchen Jia
ZQZhengkai Qian
Zhengkai Qian
ZXZongkui Xie
Zongkui Xie
The environmental control of layer houses with multi-tiered cage systems is influenced by factors such as the structure of the henhouses and the heat dissipation of the flock, leading to low precision and large fluctuations in temperature control. Based on a new combined positive- and negative-pressure ventilation (CPNPV) mode, a dynamic temperature model is constructed. Additionally, a temperature control method for a layer house is designed using a variable universe fuzzy PID control algorithm (VFPID). First, based on the principles of energy and mass balance, and by decoupling the relationship between positive- and negative-pressure ventilation volumes, a dynamic temperature model for layer houses under CPNPV was established. Then, the PID parameters and the proportional relationship between positive- and negative-pressure ventilation were optimized through fuzzy rules, and a proportional exponential function was introduced to adjust the scaling of the universe, enabling fine-tuned control. Finally, a temperature control model for the layer house was built using Simulink. The results show that the coefficients of determination (R2) of the constructed dynamic temperature models are between 0.79 and 0.88, respectively, indicating high accuracy. The designed VFPID method outperformed traditional on–off control and improved control precision by 20–23.53% and 10.34–22.22% compared with PID control and fuzzy PID(FPID) control methods, respectively. This study provides new insights for the development of environmental control equipment and precise environmental regulation of layer houses.