Mechanical ventilation is an important means of environmental control in multitier laying hen cages. The mainstream ventilation mode currently in use, negative-pressure ventilation (NPV), has the drawbacks of a large temperature difference before and after adjustment and uneven air velocity distribution. To solve these problems, this study designed and analyzed a combined positive and negative-pressure ventilation system for laying hen cages. According to the principle of the conservation of mass to increase the inlet flow in the negative-pressure ventilation system on the basis of the addition of the pressure-wind body-built positive-and-negative-pressure-combined ventilation (PNCV) system, further, computational fluid dynamics (CFD) simulation was performed to analyze the distribution of environmental parameters in the chicken cage zone (CZ) with inlet angles of positive-pressure fans set at 45°, 90°, and 30°. Simulation results showed that the PNCV system increased the average air velocity in the CZ from 0.94 m/s to 1.04 m/s, 1.28 m/s, and 0.99 m/s by actively blowing air into the cage. The maximum temperature difference in the CZ with the PNCV system was 2.91 °C, 1.80 °C, and 3.78 °C, which were all lower than 4.46 °C, the maximum temperature difference in the CZ with the NPV system. Moreover, the relative humidity remained below 80% for the PNCV system and between 80% and 85% for the NPV system. Compared with the NPV system, the PNCV system increased the vertical airflow movement, causing significant cooling and dehumidifying effects. Hence, the proposed system provides an effective new ventilation mode for achieving efficient and accurate environmental control in laying hen cages.
26 July 2024 in Sustainable Energy, Grids and Networks
The environmental control of layer houses with multi-tiered cage systems is influenced by factors such as the structure of the henhouses and the heat dissipation of the flock, leading to low precision and large fluctuations in temperature control. Based on a new combined positive- and negative-pressure ventilation (CPNPV) mode, a dynamic temperature model is constructed. Additionally, a temperature control method for a layer house is designed using a variable universe fuzzy PID control algorithm (VFPID). First, based on the principles of energy and mass balance, and by decoupling the relationship between positive- and negative-pressure ventilation volumes, a dynamic temperature model for layer houses under CPNPV was established. Then, the PID parameters and the proportional relationship between positive- and negative-pressure ventilation were optimized through fuzzy rules, and a proportional exponential function was introduced to adjust the scaling of the universe, enabling fine-tuned control. Finally, a temperature control model for the layer house was built using Simulink. The results show that the coefficients of determination (R2) of the constructed dynamic temperature models are between 0.79 and 0.88, respectively, indicating high accuracy. The designed VFPID method outperformed traditional on–off control and improved control precision by 20–23.53% and 10.34–22.22% compared with PID control and fuzzy PID(FPID) control methods, respectively. This study provides new insights for the development of environmental control equipment and precise environmental regulation of layer houses.
1 January 2024 in Journal of Industrial and Management Optimization
Aiming at the bus voltage fluctuation caused by nonlinearity, limited bus voltage change and uncertain factors such as bus voltage deviation, load and system parameter change caused by traditional droop control in DC microgrid, a precise bus voltage control scheme considering voltage constraints is proposed. Firstly, parabolic droop control is used to replace the traditional linear droop control to improve the accuracy of power distribution. On this basis, a bus voltage controller based on barrier Lyapunov function is designed to precisely control the voltage of droop control to reach the expected value. The controller adopts backstepping method to deal with nonlinear problems; the barrier Lyapunov function is used to design the system to meet the condition of voltage constraints; RBF neural network is used to eliminate the uncertainty in the system and improve the disturbance suppression ability of the system. The simulation results show that the designed controller can ensure voltage stability when the load changes and the system parameters change, and its performance is better than that of PI control. It can achieve high-precision control of bus voltage and load distribution when the state is limited. The simulation results verify that this control strategy can reduce voltage drop and achieve bus voltage stability.