The WHO has classified Helicobacter pylori as a group 1 carcinogen for stomach cancer since early 1994. However, despite the high prevalence of Helicobacter pylori infection, only about 3% of infected people eventually develop gastric cancer.Biomolecular detections of Helicobacter pylori(HP) were compared using specially modified sensors and fluorine immobilized on a carbon nanotube (HFCNT) electrode, which yielded sensitive results. Handheld voltammetric circuits were used for optimization. An anodic voltammogram of HP molecular oxidation was obtained at 0.0 V ± 0.1 (versus the Ag/AgCl/KCl) in a 0.1 ± 0.2 M NH4H2PO4 electrolyte solution. Under optimized conditions, the analytical working range was 2.98 × 103–22.127 × 10−3 CFU/mL HP using square wave (SW) stripping voltammetry, precision of R2 = 0.9857 ± 0.0005 (SWSV), the detection limit approached to 2.5 × 102 CFU/mL HP (S/N = 3).The developed techniques have been applied to diagnosis of early-stage HP infections using stomach tissue from healthy humans and gastric patients.
PURPOSE: Chemotherapy-induced peripheral neuropathy (CIPN) is a common dose-limiting side effect of neurotoxic chemotherapy that can persist for years after treatment and permanently diminish patient's long-term function and quality of life. ASCO guidelines recommend altering (eg, decreasing, delaying, or discontinuing) neurotoxic chemotherapy treatment in patients experiencing intolerable CIPN symptoms. Cancer survivors indicate they were unaware that CIPN symptoms could be permanent and that this knowledge would have affected their treatment decisions. The objective of this study is to investigate whether CIPN symptom permanence affects patient preferences for continuing versus altering their ongoing chemotherapy treatment. METHODS: Patients currently receiving taxane and/or platinum chemotherapy for breast or colorectal cancer completed the European Organisation for Research and Treatment of Cancer Quality of Life-CIPN20 patient-reported CIPN questionnaire and were asked whether they would choose to continue or alter treatment if their CIPN symptoms would be temporary or permanent. The effect of CIPN permanence on their choice to continue chemotherapy was analyzed via generalized linear mixed effects models adjusted for relevant covariates including CIPN severity, chemotherapy type, and metastatic disease. RESULTS: Surveys were completed by 66 patients, most of whom were receiving taxane treatment (83%) for nonmetastatic disease (82%). Patients were dramatically more likely to choose to alter chemotherapy treatment if their CIPN symptoms would be permanent versus temporary (odds ratio, 29.14 [95% CI, 15.31 to 55.46]; P < .001). CONCLUSION: CIPN permanence dramatically increases patient's preference to alter neurotoxic chemotherapy treatment. This finding highlights the need to improve prediction of permanent CIPN and the importance of explaining the risk of permanent CIPN when discussing with patients whether to continue or alter chemotherapy treatment to optimize long-term therapeutic outcomes in cancer survivors.
COVID-19 antibody detection is dependent on highly specialized, time-consuming techniques, such as PCR separation, DNA amplification, and other methods such as spectrophotometric absorption. For these reasons, specialized technical training is necessary because individual diagnostic treatment is difficult. We have attempted to perform rapid sensing with a detection time of only 30 s. Additionally, we used a wearable multi-layer graphene oxide nanocolloid synthetic skin tattoo probe assay for influenza and COVID-19 virus detection with an electrochemical antigen–antibody redox ionic titration circuit. Cyclic voltametric−2 V~2.0 V potential windows were used. The diagnostic detection limit was determined using stripping anodic and cathodic amplifiers, and the working probe was fabricated with a graphene molecule structure with a virus antigen-immobilized amplifier. With redox potential strength obtained within −1.0 V~−1.3 V ionic activity, anodic and cathodic current linearly increased in the phosphate-buffered saline 5 mL electrolyte. The results indicate that instant detection was enabled via individual and wearable tattoo sensors.
Pandemic human influenza detections are dependent on complex, time-consuming DNA molecular amplifications that require sophisticated PCR electrophoresis, cell culture amplification and complex spectrophotometric absorption techniques. In this study, simplified rapid electrochemical sensing methods were sought via a remote cyclic voltammetry and stripping amplifier circuit using our workstation systems. A sensing probe was prepared using human DNA and a Covid 19 antigen immobilized antibody sensing amplifier with rapid accumulation time of 30 sec. Optimal experimentation was performed using a telematics WiFi wearable circuit equipped with a bioelectrochemical analyzer-2 amplifier three electrode system. Diagnostic accumulation voltammetry and cyclic redox scanning were attempted at -2.0V~2.0V potential windows and 0.2V/Sec scan rate. Anodic and cathodic real time assay was performed using saliva swab from female patients that tested negative and positive. Diagnostic results are expected to be useful for non-contact analysis and for rapid personal testing anytime, anywhere.
Biomolecular detections of Helicobacter pylori(HP) were compared using specially modified sensors and fluorine immobilized on a carbon nanotube (HFCNT) electrode, which yielded sensitive results. Handheld voltammetric circuits were used for optimization. An anodic voltammogram of HP molecular oxidation was obtained at 0.0 V (versus the Ag/AgCl/KCl) in a 0.1M NH4H2PO4 electrolyte solution. Under optimized conditions, the analytical working range was 2.98x103-22.127x103 CFU/ml HP using square wave (SW) stripping voltammetry, precision of R2 =0.9857 (SWSV), the detection limit approached to 2.5x102 CFU/ml HP (S/N=3).The developed techniques have been applied to diagnosis of early-stage HP infections using stomach tissue from healthy humans and gastric patients.