Kyung Lee

Kyung Lee


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2022 in Molecules
Verified
Journal Article
Open access
PDF file
ICIn Hea Cho
In Hea Cho
KCKwang Jin Choi
Kwang Jin Choi
JKJihyun Kim
Jihyun Kim
KLKyung Lee
Kyung Lee
SLSuwyoung Ly
Suwyoung Ly
Staphylococcus aureus bacteria is a ubiquitous Gram-positive microorganism that causes infections related to the sudden infant death syndrome. Recently, basic detection methods depend on complicated PCR amplification, electric separation, spectric adsorption and other detection systems. However, in this study, simplified sensitive voltammetric skills are developed. To identify an effective diagnostic method for Staphylococcus aureus (SA), a voltammetric sensing probe was sought using mercury immobilized on a carbon nanotube sensor (MCN). The voltammetric MCN conditions were optimized through stripping and cyclic voltammetry. Diagnostic electrolyte was used on non-treated blood sera as an electrolyte solution. The optimum cyclic and stripping analytical working range was 0.5–4.0 mL (3 × 102~5 × 102 CFU/0.5 mL) SA. The statistic relative standard deviation of 0.1 mL SA was observed to be 0.0078 (n = 5). Using the optimum parameters, a diagnostic test was performed by the direct assay of SA in non-treated human blood and patient sera. Here, the developed results can be used for the direct assay of non-treated blood sera, organ monitoring, in-vivo diagnosis, and other assays requiring SA detection.

8 December 2024 in Microorganisms
Verified
Journal Article
Open access
PDF file
KLKyung Lee
Kyung Lee
SJSihyun Jun
Sihyun Jun
YOYeseul Oh
Yeseul Oh
SLSeojun Lee
Seojun Lee
YOYe Jun Oh
Ye Jun Oh
SLSuwyoung Ly
Suwyoung Ly
The WHO has classified Helicobacter pylori as a group 1 carcinogen for stomach cancer since early 1994. However, despite the high prevalence of Helicobacter pylori infection, only about 3% of infected people eventually develop gastric cancer.Biomolecular detections of Helicobacter pylori(HP) were compared using specially modified sensors and fluorine immobilized on a carbon nanotube (HFCNT) electrode, which yielded sensitive results. Handheld voltammetric circuits were used for optimization. An anodic voltammogram of HP molecular oxidation was obtained at 0.0 V ± 0.1 (versus the Ag/AgCl/KCl) in a 0.1 ± 0.2 M NH4H2PO4 electrolyte solution. Under optimized conditions, the analytical working range was 2.98 × 103–22.127 × 10−3 CFU/mL HP using square wave (SW) stripping voltammetry, precision of R2 = 0.9857 ± 0.0005 (SWSV), the detection limit approached to 2.5 × 102 CFU/mL HP (S/N = 3).The developed techniques have been applied to diagnosis of early-stage HP infections using stomach tissue from healthy humans and gastric patients.

6 February 2025 in Microorganisms
Verified
Journal Article
Open access
PDF file
KLKyung Lee
Kyung Lee
DKDong Ho Kim
Dong Ho Kim
SJSihyun Jun
Sihyun Jun
YOYeseul Oh
Yeseul Oh
YOYe Jun Oh
Ye Jun Oh
SLSuwyoung Ly
Suwyoung Ly
COVID-19 antibody detection is dependent on highly specialized, time-consuming techniques, such as PCR separation, DNA amplification, and other methods such as spectrophotometric absorption. For these reasons, specialized technical training is necessary because individual diagnostic treatment is difficult. We have attempted to perform rapid sensing with a detection time of only 30 s. Additionally, we used a wearable multi-layer graphene oxide nanocolloid synthetic skin tattoo probe assay for influenza and COVID-19 virus detection with an electrochemical antigen–antibody redox ionic titration circuit. Cyclic voltametric−2 V~2.0 V potential windows were used. The diagnostic detection limit was determined using stripping anodic and cathodic amplifiers, and the working probe was fabricated with a graphene molecule structure with a virus antigen-immobilized amplifier. With redox potential strength obtained within −1.0 V~−1.3 V ionic activity, anodic and cathodic current linearly increased in the phosphate-buffered saline 5 mL electrolyte. The results indicate that instant detection was enabled via individual and wearable tattoo sensors.

15 October 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
KLKyung Lee
Kyung Lee
KKKeum Sook Kim
Keum Sook Kim
SLSuwyoung Ly
Suwyoung Ly
Background/Objective: In-vivo d iabetes detection of glucose were sought using square-wave anodic stripping voltammetry (SW), with bismuth-immobilized carbon nanotube paste electrode (BCE). Methods: The optimum analytical results indicated sensitive peak signals on the BCE. The raw voltammogram was approached within the 1 mgL-1-14 mgL-1 and 10 ugL-1-140 ugL-1, detection limits with preconcentration times of 100 and 200 sec. Results: The relative standard deviation was 0.02 % (n = 15) of 10.0 mgL-1 under optimum conditions. The analytical detection limit (S/N) was attained at 8 ugL-1. The handmade microsensor was directly used in vivo on the living fish brain and human urine.Conclusion: The method was applied at real time in vivo, without requiring any pretreatment and other ionic electrolyte solutions. It can be used for medicinal and other materials requiring biological-fluid detection in real time. This study was designed to be suitable for real-time unmanned remote diagnosis and therapeutic drug injection into the body, micro-needle long-term administration, wearable artificial skin tattoo sensor, and real-time control. In addition, the glasses monitor was designed to be suitable for multitasking and multi-user control.

20 December 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
KLKyung Lee
Kyung Lee
YOYeseul Oh
Yeseul Oh
SLSeo Jun Lee
Seo Jun Lee
YOYe Jun Oh
Ye Jun Oh
KKKeum Sook Kim
Keum Sook Kim
SLSuwyoung Ly
Suwyoung Ly
Background/Objective; In-vivo diabetes detection of glucose were sought using square-wave anodic stripping voltammetry (SW), with bismuth-immobilized carbon nanotube paste electrode (BCE). Methods:The optimum analytical results indicated sensitive peak signals on the BCE. The raw voltammogram was approached within the 1mgL-1-14mgL-1 and 10ugL-1-140 ugL-1, detection limits with preconcentration times of 100 and 200 sec. Results:The relative standard deviation was 0.02 % (n=15) of 10.0 mgL-1 under optimum conditions. The analytical detection limit (S/N) was attained at 8 ugL-1. The handmade microsensor was directly used in vivo on the living fish brain and human urine. Conclusion: The method was applied at real time in vivo, without requiring any pretreatment and other ionic electrolyte solutions. It can be used for medicinal and other materials requiring biological-fluid detection in real time. This study was designed to be suitable for real-time unmanned remote diagnosis and therapeutic drug injection into the body, micro-needle long-term administration, wearable artificial skin tattoo sensor, and real-time control. In addition, the glasses monitor was designed to be suitable for multitasking and multi-user control.

26 August 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
KLKyung Lee
Kyung Lee
SLSuwyoung Ly
Suwyoung Ly
YOYeseul Oh
Yeseul Oh
SJSihyun Jun
Sihyun Jun
DKDong Ho Kim
Dong Ho Kim
Pandemic human influenza detections are dependent on complex, time-consuming DNA molecular amplifications that require sophisticated PCR electrophoresis, cell culture amplification and complex spectrophotometric absorption techniques. In this study, simplified rapid electrochemical sensing methods were sought via a remote cyclic voltammetry and stripping amplifier circuit using our workstation systems. A sensing probe was prepared using human DNA and a Covid 19 antigen immobilized antibody sensing amplifier with rapid accumulation time of 30 sec. Optimal experimentation was performed using a telematics WiFi wearable circuit equipped with a bioelectrochemical analyzer-2 amplifier three electrode system. Diagnostic accumulation voltammetry and cyclic redox scanning were attempted at -2.0V~2.0V potential windows and 0.2V/Sec scan rate. Anodic and cathodic real time assay was performed using saliva swab from female patients that tested negative and positive. Diagnostic results are expected to be useful for non-contact analysis and for rapid personal testing anytime, anywhere.