Upon the higher requirement on high-performance structures of large-scale supporting structures of offshore wind turbines, the systematic analysis on the compressive-flexural behavior and ultimate bearing capacity of tapered concrete-filled double skin steel tubular (CFDST) members designed by over-ranging parameters was performed. Investigating the entire-process mechanism, e.g., the moment–deformation response, stress development, interaction stress, and subassembly contribution, was based on the finite element (FE) analysis, where the moment–deformation curve can be distinguished by four characteristic points, and the transverse local buckling of outer tube partly weakens distribution height of interface pressure in compression zone compared to that in tension zone. Influences of material strengths and geometric parameters were examined by the parametric study, e.g., increasing tapered angle (ψ) slightly reduces the bearing capacity; the higher axial compression ratio (n) contributes a noteworthy action on the post-peak behavior and carrying capacity, e.g., the bearing capacities at n = 0.9 and n = 0.5 reduce by 64.14% and 18.44% compared to capacity at n = 0.1, respectively; influence of Do/to ratio is more significant than Di/ti ratio. Subsequently, the modified cross-sectional stress integration (CSI) method was proposed to predict the moment–strain (M-ε) curves of tapered CFDST members; meanwhile, a confined concrete model with transverse confinement stress as an explicit parameter was modified, and influences of different confined concrete models on predicting M-ε curves were compared. Finally, design methods based on the modified CSI method and limit state method were proposed as a simplified calculation method to determine the correlative relationship of axial compressive strength and moment-resisting capacity (N-M curve).
As a critical component of substations, the substation frames are characterized by significant height and span, which presents substantial challenges and risks in conducting dynamic response tests using traditional sensors. To simplify these difficulties, this paper introduces an experimental method utilizing MEMS sensor-based vibration acquisition. In this approach, smartphones equipped with MEMS sensors are deployed on the target structure to collect vibration data under environmental excitation. This method was applied in a dynamic field test of a novel composite substation frame. During the test, the proposed MEMS-based vibration acquisition method was conducted in parallel with traditional ultra-low-frequency vibration acquisition methods to validate the accuracy of the MEMS data. The results demonstrated that the MEMS sensors not only simplified the testing process but also provided reliable data, offering greater advantages in testing convenience compared with traditional contact methods. The modal parameters of the substation frame, including modal frequencies, damping ratios, and mode shapes, were subsequently identified using the covariance-driven stochastic subspace identification method. The experimental methodology and findings presented in this paper offer valuable insights for structural dynamic response testing and the wind-resistant design of substation frames.
A tapered concrete-filled double-skin steel tubular (TCFDST) structure has been used as the main framework in transmission towers, offshore facility platforms, and turbine towers owing to its excellent mechanical properties. In order to solve the difficulties of calculating the axial compressive capacity of TCFDST members due to the variations in cross-section, this paper applied heuristic optimization algorithms such as Genetic Algorithms (GAs), Particle Swarm Optimization (PSO), Simulated Annealing (SA), and Ant Colony Optimization (ACO) to enhance a Backpropagation Neural Network (BPNN) model. A predictive model incorporating both global and local optimization strategies for the axial compressive capacity of a TCFDST structure is proposed. A comprehensive axial database for TCFDST members, comprising 1327 sets of experimental and finite element analysis results, was established, with ten types of component dimensions and material parameters selected as input variables and compressive bearing capacity as the output variable. This study developed and assessed four BPNN models, each optimized by a different heuristic algorithm, against various machine learning algorithms and standards. The heuristic-algorithm-optimized BPNN models demonstrated superior accuracy in predicting the axial compressive capacity of TCFDST members. Through parametric analysis, this study identified the relationship between the model’s bearing capacity predictions and each input parameter, confirming the model’s broad applicability. The optimized BPNN model, refined with heuristic algorithms, provides a significant reference for addressing the computational challenges associated with the load-bearing capacity of TCFDST structures and facilitating their application.